Page 20 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 
N/A 
 
15 
Terminals 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Mains plug on non-detachable 
cord meets the appropriate 
standard  
(see appended table 14) 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
  
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 
 
No risk of insertion in mains socket-outlets  
 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No such outlets 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets  
 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II equipment 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ..................: 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
See below 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
See below 
 
Not soldered to conductors of a printed circuit board   Not soldered to printed circuit 
board directly, one conductor 
connect to main switch by 
hook-in and additional fixed by 
heat shrinkable tube, another 
conductor connect with primary 
wire connector connected to 
CN1 on power board 
 
 
 
 
Page 21 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
5N performed in any direction 
to the connection. No hazards. 
 
Wire secured by additional means to the  
conductor   
  
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
No such screws and nuts 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
For  switch terminal  
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
For suitable connector used  
15.3.6 
Terminals to 15.3.3 have sizes required by table 16    
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
  
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
Cord-connected equipment 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  .......................................................: 
(see appended table 14) 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II equipment 
N/A 
 
 
 
 
Page 22 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
(see appended table 14) 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)  
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
Cross-sectional areas of 
signal input/output cord 
suitable for the intended 
current 
16.5 
Adequate strain relief on external flexible cords  
After test on each power cord 
type, measured max. 
displacement: 0.8mm 
 
Not possible to push cord back into equipment  
Cord bushing used 
 
Strain relief device unlikely to damage flexible  
cord  
 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
Class II equipment 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
No such equipment 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
17 
Electrical connections and mechanical fixings 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times  
Torque used for screws fixing 
the power board: 0.5Nm 
 
- screws into non-metallic material: 10 times  
Torque used for screws fixing 
the power board assembly and 
metal plate onto wood 
enclosure: 0.5Nm 
17.2 
Correct introduction into female threads in non-
metallic material  
 
N/A 
17.3 
Cover fixing screws: captive  
 
N/A 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Checked by Øx10 screws 
 
 
 
 
Page 23 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
17.4 
No loosening of conductive parts carrying a 
current > 0,2 A 
 
N/A 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected  
2N applied, no loosening 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
N/A 
18.1 
Picture tube separately approved to IEC 61965  ....: 
No picture tube used 
N/A 
 
Picture tube separately approved to 18.2  .............: 
  
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
19 
Stability and mechanical hazards 
 
Mass of the equipment exceeding 7 kg  ................: 
Mass: 8.46kg 
 
Apparatus intended to be fastened in place 
– 
suitable instructions  .............................................: 
No such apparatus 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
  
19.2 
100 N force applied vertically downwards  
 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability  
 
N/A 
19.4 
Edges or corners not hazardous  
Edges and corners are 
smoothed 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum 
dimension > 450 mm, pass the test of 19.5.1  
 
N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
20 
Resistance to fire 
20.1 
Electrical components and mechanical parts  
Page of 105
Display