Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15
Terminals
P
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Mains plug on non-detachable
cord meets the appropriate
standard
cord meets the appropriate
standard
(see appended table 14)
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
P
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such outlets
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II equipment
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
at 25 A ..................:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
See below
P
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords
See below
P
Not soldered to conductors of a printed circuit board Not soldered to printed circuit
board directly, one conductor
connect to main switch by
hook-in and additional fixed by
heat shrinkable tube, another
conductor connect with primary
wire connector connected to
CN1 on power board
connect to main switch by
hook-in and additional fixed by
heat shrinkable tube, another
conductor connect with primary
wire connector connected to
CN1 on power board
P
Page 21 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
5N performed in any direction
to the connection. No hazards.
to the connection. No hazards.
P
Wire secured by additional means to the
conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
No such screws and nuts
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
For switch terminal
P
Clamping of conductor and insulation if not soldered
or held by screws
or held by screws
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
sectional area of conductors, for the rated current of
the equipment
For suitable connector used
P
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
P
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
P
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
Cord-connected equipment
N/A
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
External flexible cords
P
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords .......................................................:
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords .......................................................:
(see appended table 14)
P
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
Class II equipment
N/A
Page 22 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
(see appended table 14)
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
bending and mechanical stress (3.2 of IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cross-sectional areas of
signal input/output cord
suitable for the intended
current
signal input/output cord
suitable for the intended
current
P
16.5
Adequate strain relief on external flexible cords
After test on each power cord
type, measured max.
displacement: 0.8mm
type, measured max.
displacement: 0.8mm
P
Not possible to push cord back into equipment
Cord bushing used
P
Strain relief device unlikely to damage flexible
cord
P
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
Class II equipment
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
P
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
fitted with detachable cord set with appliance inlet to
IEC 60320-1
No such equipment
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
17
Electrical connections and mechanical fixings
P
17.1
Torque test to table 20
P
- screws into metal: 5 times
Torque used for screws fixing
the power board: 0.5Nm
the power board: 0.5Nm
P
- screws into non-metallic material: 10 times
Torque used for screws fixing
the power board assembly and
metal plate onto wood
enclosure: 0.5Nm
the power board assembly and
metal plate onto wood
enclosure: 0.5Nm
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
N/A
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
by a screw whose length is 10 times its diameter
Checked by Øx10 screws
P
Page 23 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
17.4
No loosening of conductive parts carrying a
current > 0,2 A
current > 0,2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
2N applied, no loosening
P
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
N/A
18.1
Picture tube separately approved to IEC 61965 ....:
No picture tube used
N/A
Picture tube separately approved to 18.2 .............:
N/A
18.2
Non-intrinsically protected tubes tested to 18.2
N/A
19
Stability and mechanical hazards
P
Mass of the equipment exceeding 7 kg ................:
Mass: 8.46kg
P
Apparatus intended to be fastened in place
–
suitable instructions .............................................:
No such apparatus
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
to point of least stability
N/A
19.4
Edges or corners not hazardous
Edges and corners are
smoothed
smoothed
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum
dimension > 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum
dimension > 450 mm, pass the test of 19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
Resistance to fire
P
20.1
Electrical components and mechanical parts
P
Click on the first or last page to see other HKTS 200SUB (serv.man2) service manuals if exist.