DOWNLOAD Harman Kardon HKTS 200SUB (serv.man2) Service Manual ↓ Size: 5.65 MB | Pages: 105 in PDF or view online for FREE

Model
HKTS 200SUB (serv.man2)
Pages
105
Size
5.65 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-200sub-sm2.pdf
Date

Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 24 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 
N/A 
 
b) Exemption for small components as defined in 
20.1  
 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4  
 
20.1.2 
Insulation of internal wiring working at 
voltages > 4 kV or leaving an internal fire enclosure, 
or located within the areas mentioned in Table 21, 
not contributing to the spread of fire  
No working voltages > 4 kV 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure  
V-1 PCB or better used for all 
PCBs. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
As above. 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
Transformer material and other 
insulation materials comply. 
Foam material V-2 for models 
with rating 110-120V only, for 
others V-1 foam material used 
on internal wires. Wood 
enclosure with min. thickness 
13mm complies as V-1. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 
N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit 
voltage > 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No such potential ignition 
sources 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
N/A 
 
 
 
 
Page 25 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
A.5 
Marking and instructions 
IP20, not applied for 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 
N/A 
A.10 
Insulation requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1  
EUT not intended for 
connection to 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
N/A 
L. 5 
Marking and instructions 
No such apparatus 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
 
N/A 
 
 
 
 
Page 26 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 
Insulation requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
 
 
 
Page 27 of 89 
 
 
 
Report No.: 17029429 001 
 
 
TRF No. IEC60065K 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
-- 
-- 
 
Position of the functional switch (W)  .....................: 
-- 
-- 
Operating conditions 
Normal operating 
Un (V) 
f (Hz) 
In (A) 
Pn (W) 
Rated output 
Max normal load: the maximum non-clipped output power. (for reference only) 
90 
50 
2.25 
131 
-- 
90 
60 
2.33 
131 
-- 
100 
50 
2.34 
146 
-- 
100 
60 
2.30 
145 
-- 
120 
50 
3.96 
291 
-- 
120 
60 
3.93 
294 
-- 
127.2 
50 
3.67 
283 
-- 
127.2 
60 
3.71 
289 
-- 
132 
50 
3.62 
295 
-- 
132 
60 
3.62 
296 
-- 
Max normal load: 1/8 of the maximum non-clipped output power. 
90 
50 
0.43 
21.5 
-- 
90 
60 
0.43 
21.6 
-- 
100 
50 
0.42 
22.7 
-- 
100 
60 
0.42 
23.2 
-- 
120 
50 
0.39 
24.4 
-- 
120 
60 
0.40 
24.4 
-- 
127.2 
50 
0.38 
24.7 
-- 
127.2 
60 
0.38 
24.7 
-- 
132 
50 
0.37 
24.9 
-- 
132 
60 
0.37 
24.9 
-- 
Note: The max. input power is 24.4W, rated max. power is 200W, (24.4-200)/200x100%=-87.8%, limit is 
+10% 
Max normal load: the maximum non-clipped output power. (for reference only) 
198 
50 
2.13 
265 
-- 
198 
60 
2.15 
266 
-- 
220 
50 
2.00 
277 
-- 
220 
60 
2.12 
285 
-- 
240 
50 
2.03 
286 
-- 
240 
60 
1.98 
285 
-- 
Page of 105
Display