Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 24 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at
voltages > 4 kV or leaving an internal fire enclosure,
or located within the areas mentioned in Table 21,
not contributing to the spread of fire
voltages > 4 kV or leaving an internal fire enclosure,
or located within the areas mentioned in Table 21,
not contributing to the spread of fire
No working voltages > 4 kV
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
V-1 PCB or better used for all
PCBs.
PCBs.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
As above.
P
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Transformer material and other
insulation materials comply.
Foam material V-2 for models
with rating 110-120V only, for
others V-1 foam material used
on internal wires. Wood
enclosure with min. thickness
13mm complies as V-1.
insulation materials comply.
Foam material V-2 for models
with rating 110-120V only, for
others V-1 foam material used
on internal wires. Wood
enclosure with min. thickness
13mm complies as V-1.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
voltage > 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No such potential ignition
sources
sources
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
N/A
Page 25 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
A.5
Marking and instructions
IP20, not applied for
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10
Insulation requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
N/A
Complies with IEC 62151 clause 1
EUT not intended for
connection to
telecommunication networks
connection to
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
N/A
L. 5
Marking and instructions
No such apparatus
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
Page 26 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 27 of 89
Report No.: 17029429 001
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
--
--
Position of the functional switch (W) .....................:
--
--
Operating conditions
Normal operating
Un (V)
f (Hz)
In (A)
Pn (W)
Rated output
Max normal load: the maximum non-clipped output power. (for reference only)
90
50
2.25
131
--
90
60
2.33
131
--
100
50
2.34
146
--
100
60
2.30
145
--
120
50
3.96
291
--
120
60
3.93
294
--
127.2
50
3.67
283
--
127.2
60
3.71
289
--
132
50
3.62
295
--
132
60
3.62
296
--
Max normal load: 1/8 of the maximum non-clipped output power.
90
50
0.43
21.5
--
90
60
0.43
21.6
--
100
50
0.42
22.7
--
100
60
0.42
23.2
--
120
50
0.39
24.4
--
120
60
0.40
24.4
--
127.2
50
0.38
24.7
--
127.2
60
0.38
24.7
--
132
50
0.37
24.9
--
132
60
0.37
24.9
--
Note: The max. input power is 24.4W, rated max. power is 200W, (24.4-200)/200x100%=-87.8%, limit is
+10%
+10%
Max normal load: the maximum non-clipped output power. (for reference only)
198
50
2.13
265
--
198
60
2.15
266
--
220
50
2.00
277
--
220
60
2.12
285
--
240
50
2.03
286
--
240
60
1.98
285
--
Click on the first or last page to see other HKTS 200SUB (serv.man2) service manuals if exist.