DOWNLOAD Harman Kardon HKTS 200SUB (serv.man2) Service Manual ↓ Size: 5.65 MB | Pages: 105 in PDF or view online for FREE

Model
HKTS 200SUB (serv.man2)
Pages
105
Size
5.65 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-200sub-sm2.pdf
Date

Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 12 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Primary wires connected to 
power board by connector. 
Secondary wires from power 
board & other wires connected  
to secondary PCB by 
pluggable wire connector or 
hooked-in soldering or 
soldering and  additionally 
fixed by glue. 
 
Vibration test carried out  ......................................: 
Yes 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
No such parts 
N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Internal wires can not touch 
hot parts or sharp edges 
which can damage its 
insulation 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
Triple insulated wire used on 
transformer TR3 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
Type: mains plug on non-
detachable power cord 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No such switch 
N/A 
8.19.2 
Mains switch ON indication  
  
N/A 
8.20 
Switch not fitted in the mains cord  
Mains switch located on rear 
enclosure 
N/A 
8.21 
Bridging components comply with clause 14  
No such components used 
N/A  
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
< 1000 V 
N/A 
9.1.1.1 
a) Open circuit voltages  
(see appended table 9.1.1) 
 
b) Touch current measured from terminal devices 
using the network in annex D ...............................: 
(see appended table 9.1.1) 
 
c) Discharge not exceeding 45 
μC  
Discharge not exceeding 
45
μC 
 
 
 
 
Page 13 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
d) Energy of discharge not exceeding 350 mJ  
Open circuit voltage < 15kV 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No such holes in enclosure 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls used 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................: 
After 2 s, measured value  
< 15V peak 
 
If C is not greater than 0,1 
μF no test needed  
X2-capacitors with total 
capacitance 0.44 µF used 
between L and N 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
For metal rear panel only 
9.2 
No hazard after removing a cover by hand  
Tools are required 
N/A 
 
10 
Insulation requirements 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ............................................................: 
Tested between primary and 
accessible parts, after tested, 
EUT complied with the 
requirements of 10.3 
10.2 
Humidity treatment 48 h or 120 h  .........................: 
93% R.H., 40ºC, 120h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
Class II equipment 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
 
11 
Fault conditions 
11.1 
No shock hazard under fault condition  
(see appended table 11.1) 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
No flames 
N/A 
 
No hazard from softening solder  
No solder softened 
N/A 
 
 
 
 
Page 14 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Soldered terminations not used  as protective 
mechanism  
 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table 11.2) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
  
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
None exceeds limits 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ...............: 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
  
N/A 
 
12 
Mechanical strength 
12.1.1 
Bump test where mass >7 kg  
Mass: 8.46kg 
12.1.2 
Vibration test  
 
12.1.3 
Impact hammer test  
0.5J, 3times 
(After tested, no damage and 
EUT can withstand the 
dielectric strength test as 
specified in 10.3) 
 
Steel ball test  
2J, 1time 
(After tested, no damage and 
EUT can withstand the 
dielectric strength test as 
specified in 10.3) 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg     
N/A 
 
 
 
 
Page 15 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
12.1.5 
Thermoplastic enclosures stress relief test  
Internal plastic enclosure 
considered.  
Test conditions: 75 °C, 7 hrs 
12.2 
Fixing of knobs, push buttons, keys and levers  
  
12.3 
Remote controls with hazardous live parts  
No such remote controls 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
No such sockets 
N/A 
12.6 
Telescoping or rod antennas construction  
No antennas used 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
13 
Clearances and creepage distances 
13.1 
Clearances in accordance with 13.3  
(see appended table 13.3 & 
13.4) 
 
Creepage distances in accordance with 13.4  
 
13.2 
Determination of working voltage  
(see appended table 13.2) 
13.3 
Clearances  
(see appended table 13.3 & 
13.4) 
13.3.1 
General  
 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............: 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
 
N/A 
13.3.4 
Measurement of transient voltages  
 
N/A 
13.4 
Creepage distances  
(see appended table 13.3 & 
13.4) 
 
Creepage distances greater than table 11 minimum 
values  
 
13.5 
Printed boards  
No such printed boards 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
No such parts 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
Page of 105
Display