Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 12 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires connected to
power board by connector.
Secondary wires from power
board & other wires connected
to secondary PCB by
pluggable wire connector or
hooked-in soldering or
soldering and additionally
fixed by glue.
power board by connector.
Secondary wires from power
board & other wires connected
to secondary PCB by
pluggable wire connector or
hooked-in soldering or
soldering and additionally
fixed by glue.
P
Vibration test carried out ......................................:
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
No such parts
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Internal wires can not touch
hot parts or sharp edges
which can damage its
insulation
hot parts or sharp edges
which can damage its
insulation
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Triple insulated wire used on
transformer TR3
transformer TR3
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
Type: mains plug on non-
detachable power cord
detachable power cord
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No such switch
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
Mains switch located on rear
enclosure
enclosure
N/A
8.21
Bridging components comply with clause 14
No such components used
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
< 1000 V
N/A
9.1.1.1
a) Open circuit voltages
(see appended table 9.1.1)
P
b) Touch current measured from terminal devices
using the network in annex D ...............................:
using the network in annex D ...............................:
(see appended table 9.1.1)
P
c) Discharge not exceeding 45
μC
Discharge not exceeding
45
45
μC
P
Page 13 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
d) Energy of discharge not exceeding 350 mJ
Open circuit voltage < 15kV
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No such holes in enclosure
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls used
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................:
of the mains plug; voltage (V) after 2 s .................:
After 2 s, measured value
< 15V peak
P
If C is not greater than 0,1
μF no test needed
X2-capacitors with total
capacitance 0.44 µF used
between L and N
capacitance 0.44 µF used
between L and N
P
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
P
b) Test hook of fig. 4 for 10 s (20 N)
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
For metal rear panel only
P
9.2
No hazard after removing a cover by hand
Tools are required
N/A
10
Insulation requirements
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ............................................................:
Tested between primary and
accessible parts, after tested,
EUT complied with the
requirements of 10.3
accessible parts, after tested,
EUT complied with the
requirements of 10.3
P
10.2
Humidity treatment 48 h or 120 h .........................:
93% R.H., 40ºC, 120h
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
Class II equipment
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
(see appended table 11.1)
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
No flames
N/A
No hazard from softening solder
No solder softened
N/A
Page 14 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table 11.2)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
None exceeds limits
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ...............:
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ...............:
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
N/A
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
Mass: 8.46kg
P
12.1.2
Vibration test
P
12.1.3
Impact hammer test
0.5J, 3times
(After tested, no damage and
EUT can withstand the
dielectric strength test as
specified in 10.3)
EUT can withstand the
dielectric strength test as
specified in 10.3)
P
Steel ball test
2J, 1time
(After tested, no damage and
EUT can withstand the
dielectric strength test as
specified in 10.3)
EUT can withstand the
dielectric strength test as
specified in 10.3)
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
Page 15 of 89
Report No.: 17029429 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
12.1.5
Thermoplastic enclosures stress relief test
Internal plastic enclosure
considered.
considered.
Test conditions: 75 °C, 7 hrs
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
No such remote controls
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
No such sockets
N/A
12.6
Telescoping or rod antennas construction
No antennas used
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
(see appended table 13.3 &
13.4)
13.4)
P
Creepage distances in accordance with 13.4
P
13.2
Determination of working voltage
(see appended table 13.2)
P
13.3
Clearances
(see appended table 13.3 &
13.4)
13.4)
P
13.3.1
General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............:
with table 8 and, where applicable, table 9 ............:
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
(see appended table 13.3 &
13.4)
13.4)
P
Creepage distances greater than table 11 minimum
values
values
P
13.5
Printed boards
No such printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No such parts
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
Click on the first or last page to see other HKTS 200SUB (serv.man2) service manuals if exist.