Harman Kardon HK 3380 (serv.man11) EMC - CB Certificate ▷ View online
- Page 3 of 3 -
Photos
Order
No.
65742
- Page 1 of 7 -
www.nemko.com
Report No. 65742
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location Measured
U1
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 - Antenna terminal
Pole 2 - Antenna terminal
Pole 2 - Antenna terminal
-
-
-
-
-
-
0,03 V peak
0.03 V peak
0.03 V peak
Pass
Pass
Pass
Pole 1 - other part or contact
Pole 2 - other part or contact
Pole 2 - other part or contact
-
-
-
-
-
-
0,03 V peak
0.03 V peak
0.03 V peak
Pass
Pass
Pass
Comments:
Only U2 have been recorded due to the use of a linear transformer in power supply.
- Page 2 of 7 -
www.nemko.com
Report No. 65742
11
FAULT CONDITIONS TESTS
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V
—
Ambient temperature (
o
C) ...................................... :
24 -26 °C
—
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse
fuse
Mains power/temperatures/results
D602
S-c
207
A - C
30 min. F601
1,07 A
Normal operating.
Input current stabilised at 1,06A.
R605 damaged.
No hazard.
Input current stabilised at 1,06A.
R605 damaged.
No hazard.
D602
S-c
253
A - C
30 min. F601
1,15 A
Normal operating.
Input current stabilised at 1,12A.
R605 damaged.
No hazard.
Input current stabilised at 1,12A.
R605 damaged.
No hazard.
D605
S-c
253
A - C
30 min. F601
1,14 A
Normal operating.
Input current stabilised at 1,12A.
R606 damaged.
No hazard.
Input current stabilised at 1,12A.
R606 damaged.
No hazard.
C611
S-c
207
-
10 min. F601
0,60 A
Output signal off immediately.
Input current stabilised at 0,18A.
R605, R606 opened.
No hazard.
Input current stabilised at 0,18A.
R605, R606 opened.
No hazard.
C611
S-c
253
-
10 min. F601
0,70 A
Output signal off immediately.
Input current stabilised at 0,24A.
R605, R606 opened.
No hazard.
Input current stabilised at 0,24A.
R605, R606 opened.
No hazard.
C613
S-c
253
-
50 min. F601
0,42 A
Output signal off immediately.
Input current stabilised at 0,26A.
No component damaged.
No hazard.
Input current stabilised at 0,26A.
No component damaged.
No hazard.
D601
S-c
207
AC - +
30 min. F601,
F603,
F604
F604
6,10 A
Normal operating.
Input current stabilised at 1,00A.
F604 opened.
No hazard.
Input current stabilised at 1,00A.
F604 opened.
No hazard.
D601
S-c
253
AC - +
30 min. F601,
F603,
F604
F604
10,1 A
Normal operating.
Input current stabilised at 1,06A.
F604 opened.
No hazard.
Input current stabilised at 1,06A.
F604 opened.
No hazard.
D601
S-c
207
AC - -
30 min. F601,
F603,
F604
F604
5,40 A
Normal operating.
Input current stabilised at 0,99A.
F603 opened.
No hazard.
Input current stabilised at 0,99A.
F603 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 3 of 7 -
www.nemko.com
Report No. 65742
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse
fuse
Mains power/temperatures/results
D601
S-c
253
AC - -
30 min. F601,
F603,
F604
F604
8,40 A
Normal operating.
Input current stabilised at 1,07A.
F603 opened.
No hazard.
Input current stabilised at 1,07A.
F603 opened.
No hazard.
C601 S-c 207 - 10
min.
F601,
F603,
F604
F603,
F604
-
Output signal off immediately.
Input current stabilised at 0,12A.
F603, F604 opened.
No hazard.
Input current stabilised at 0,12A.
F603, F604 opened.
No hazard.
C601 S-c 253 - 10
min.
F601,
F603,
F604
F603,
F604
-
Output signal off immediately.
Input current stabilised at 0,14A.
F603, F604 opened.
No hazard.
Input current stabilised at 0,14A.
F603, F604 opened.
No hazard.
Q319
S-c
253
C - E
10 min. F601,
F603,
F604
F604
9,10 A
Unit shut down immediately.
Input current stabilised at 0,01A.
Q317, Q319, Q321, R349, R355
damaged.
No hazard.
Input current stabilised at 0,01A.
Q317, Q319, Q321, R349, R355
damaged.
No hazard.
Q319
S-c
253
B - C
10 min. F601,
F603,
F604
F604
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Q321
S-c
253
C - E
10 min. F601,
F603,
F604
F604
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F603, F604 opened.
Q319 damaged.
No hazard.
Input current stabilised at 0,01A.
F603, F604 opened.
Q319 damaged.
No hazard.
Q321
S-c
253
B - C
10 min. F601,
F603,
F604
F604
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C307 S-c 253 - 30
min.
F601,
F603,
F604
F603,
F604
1,60 A
L ch. signal output off immediately.
Input current stabilised at 0,80A.
R351 opened.
No hazard.
Input current stabilised at 0,80A.
R351 opened.
No hazard.
C309 S-c 253 - 40
min.
F601,
F603,
F604
F603,
F604
1,50 A
L ch. signal output off immediately.
Input current stabilised at 0,69A.
R353 opened. No hazard.
Input current stabilised at 0,69A.
R353 opened. No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other HK 3380 (serv.man11) service manuals if exist.