Harman Kardon HK 3380 (serv.man11) EMC - CB Certificate ▷ View online

 
 
- Page 3 of 3 - 
 
Photos 
 Order 
No. 
65742 
 
 
 
 
 
 
 
 
- Page 1 of 7 - 
 
 
www.nemko.com
 
Report No.  65742 
 
 
 
 
ATTACHMENT: Tables to EN/IEC 60065 7
th
 edition 
 
 
9.1.1.1 
Touch current expressed as voltages U1 and U2 in Annex D 
Location Measured 
U1 
V (peak) 
Measured U1 
V (DC) 
Measured U2 
V (peak) 
Limits : 
U1 Max 35V (peak) 
U1 Max 1.1V (DC) 
U2 Max 0.35V (peak) 
Pole 1 - Antenna terminal 
Pole 2 - Antenna terminal 


0,03 V peak 
0.03 V peak 
Pass 
Pass 
Pole 1 - other part or contact 
Pole 2 - other part or contact 


0,03 V peak 
0.03 V peak 
Pass 
Pass 
 
 
 
 
 
Comments: 
Only U2 have been recorded due to the use of a linear transformer in power supply. 
 
 
 
 
 
 
 
- Page 2 of 7 - 
 
 
www.nemko.com
 
Report No.  65742 
 
 
11 
FAULT CONDITIONS TESTS
 
 
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V 
— 
 
Ambient temperature (
o
C) ...................................... :
24 -26 °C 
— 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse 
Mains power/temperatures/results 
D602 
S-c 
207 
A - C 
30 min.  F601 
1,07 A 
Normal operating. 
Input current stabilised at 1,06A. 
R605 damaged. 
No hazard. 
D602 
S-c 
253 
A - C 
30 min.  F601 
1,15 A 
Normal operating. 
Input current stabilised at 1,12A. 
R605 damaged. 
No hazard. 
D605 
S-c 
253 
A - C 
30 min.  F601 
1,14 A 
Normal operating. 
Input current stabilised at 1,12A. 
R606 damaged. 
No hazard. 
C611 
S-c 
207 
10 min.  F601 
0,60 A 
Output signal off immediately. 
Input current stabilised at 0,18A. 
R605, R606 opened. 
No hazard. 
C611 
S-c 
253 
10 min.  F601 
0,70 A 
Output signal off immediately. 
Input current stabilised at 0,24A. 
R605, R606 opened. 
No hazard. 
C613 
S-c 
253 
50 min.  F601 
0,42 A 
Output signal off immediately. 
Input current stabilised at 0,26A. 
No component damaged. 
No hazard. 
D601 
S-c 
207 
AC - + 
30 min.  F601, 
F603, 
F604 
6,10 A 
Normal operating. 
Input current stabilised at 1,00A. 
F604 opened. 
No hazard. 
D601 
S-c 
253 
AC - + 
30 min.  F601, 
F603, 
F604 
10,1 A 
Normal operating. 
Input current stabilised at 1,06A. 
F604 opened. 
No hazard. 
D601 
S-c 
207 
AC - - 
30 min.  F601, 
F603, 
F604 
5,40 A 
Normal operating. 
Input current stabilised at 0,99A. 
F603 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
         
         
 
 
 
- Page 3 of 7 - 
 
 
www.nemko.com
 
Report No.  65742 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse 
Mains power/temperatures/results 
D601 
S-c 
253 
AC - - 
30 min.  F601, 
F603, 
F604 
8,40 A 
Normal operating. 
Input current stabilised at 1,07A. 
F603 opened. 
No hazard. 
C601 S-c 207 -  10 
min. 
F601, 
F603, 
F604 
Output signal off immediately. 
Input current stabilised at 0,12A. 
F603, F604 opened. 
No hazard. 
C601 S-c 253 -  10 
min. 
F601, 
F603, 
F604 
Output signal off immediately. 
Input current stabilised at 0,14A. 
F603, F604 opened. 
No hazard. 
Q319 
S-c 
253 
C - E 
10 min.  F601, 
F603, 
F604 
9,10 A 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
Q317, Q319, Q321, R349, R355 
damaged. 
No hazard. 
Q319 
S-c 
253 
B - C 
10 min.  F601, 
F603, 
F604 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
Q321 
S-c 
253 
C - E 
10 min.  F601, 
F603, 
F604 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F603, F604 opened. 
Q319 damaged. 
No hazard. 
Q321 
S-c 
253 
B - C 
10 min.  F601, 
F603, 
F604 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
C307 S-c 253 -  30 
min. 
F601, 
F603, 
F604 
1,60 A 
L ch. signal output off immediately.
Input current stabilised at 0,80A. 
R351 opened. 
No hazard. 
C309 S-c 253 -  40 
min. 
F601, 
F603, 
F604 
1,50 A 
L ch. signal output off immediately.
Input current stabilised at 0,69A. 
R353 opened.  No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 