www.nemko.com
Report No. 65742
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal link and fuse
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
The thermal link in main
transformer, separately
approved, see appended table,
list of critical components.
transformer, separately
approved, see appended table,
list of critical components.
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are certified according
to IEC60127
to IEC60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuse;
F601: T4A L 250V,
F602: T2.5A L 250V,
F603, F604: T6.3A L 250V
to the fuse;
F601: T4A L 250V,
F602: T2.5A L 250V,
F603, F604: T6.3A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that
fuse-links can be connected in
parallel
fuse-links can be connected in
parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N
PTC-S devices (15 W) category V-1 or better
None
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such components
N
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
No mains switch, but mains
relay provided and certified
according to IEC61058-1 by
SEMKO.
See appended table, list of
critical components.
relay provided and certified
according to IEC61058-1 by
SEMKO.
See appended table, list of
critical components.
P
TRF No: IEC/EN 60065F
- Page 17 of 32 -
www.nemko.com
Report No. 65742
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved relay.
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
Apparatus surge : 14A
Socket outlet surge : 20A
Total surge : 34A
The measured surge current
value is less than rated surge
current rating of the mains
relay. OK.
Socket outlet surge : 20A
Total surge : 34A
The measured surge current
value is less than rated surge
current rating of the mains
relay. OK.
P
Socket outlet current marking correct
Socket outlet marking:
SWITCHED, 50W MAX, 0.25A
P
14.7 Safety
interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
No voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
No motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
TRF No: IEC/EN 60065F
- Page 18 of 32 -
www.nemko.com
Report No. 65742
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10 Batteries
No batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
No optocouplers
N
Optocouplers comply with Cl. 8
N
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N
14.12
Surge suppression varistors
No surge suppression varistors
N
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
TRF No: IEC/EN 60065F
- Page 19 of 32 -
www.nemko.com
Report No. 65742
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved mains plug and
socket-outlet provided, see list
of critical components.
socket-outlet provided, see list
of critical components.
P
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Only phono/RCA, Mini jack
and Antenna terminals used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of plugs
that can make permanent contact
with a mains socket outlet.
and Antenna terminals used.
Banana plug type speaker
terminal also used, but they
are accepted due to below
note.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of plugs
that can make permanent contact
with a mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with the
symbol
symbol
N
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
The equipment under test is
not an adaptor.
not an adaptor.
N
15.2
Provision for protective earthing
N
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus
N
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
output voltage: output circuit not connected to
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1 Ω at 25 A ................... :
N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
P
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
Apparatus is not for permanent
connection.
connection.
N
15.3.2
Reliable connection of non-detachable cords:
P
TRF No: IEC/EN 60065F