Harman Kardon HD 950 (serv.man3) EMC - CB Certificate ▷ View online

 
                                                                                Page 39 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Rubber Insulated Cables of Rated Voltage up to 
and including 450/750V” and insert “Singapore 
Standard 236: Flexible Cords”, whenever they 
appear in this clause. 
Delete “CEE Publication 13, CEE Publication 2 
and IEC Publication 173: Colours of the Cores of 
Flexible Cables and Cords” whenever they 
appear in this clause. 
16.2 
Delete the notes in small print and insert “A 
nominal cross-sectional area of 0.75 mm
2
 will 
satisfy this requirement”. 
 Pass 
16.4b 
Delete “Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods” and insert “Subclause 9.1 
of SS 236”: 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has 
a carrier C supporting two pulleys A and B 
arranged so that the cord is horizontal between 
the pulleys. The carrier moves backward and 
forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
as given in Table 1. 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample 
shall be loaded with the current specified in Table 
2. 
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral. 
During the test no open-circuit in any core or 
short-circuit between cores shall occur. 
After the test, any sheath on cords having three 
 Pass 
 
                                                                                Page 40 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage 
test specified in Subclause 8.2. or 8.3 as 
appropriate, but with a test voltage not exceeding 
2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and 5, see the 
CB bulletin. 
*In parenthesis: clauses according to IEC60065:1992. 
 
 
 
National differences MALAYSIA, according to CB bulletin No. 110A 
IEC 60065(2001)
 
+ Amendment 1 (2005).
 
 
 
Energy Commission circular no.1 year 2003 
(no.1/2003) 
States that a Certificate of Approval is required 
for manufacturing, selling, Advertising, displaying 
or importing into Malaysia, electrical/electronic 
products Listed in Annex A. 
 N/A 
 
The supply voltage in Malaysia is 240 Vac, at 
50Hz. 
 Pass 
 
Class 0 and 01 appliances are not allowed 
 Pass 
 
13A fused plug-tops shall comply to Malaysian 
standard (MS 589:Part1:1997), if applicable. 
Same as BS1363 type. 
Pass 
 
2-pin plug tops shall comply to Malaysian 
standard (MS 1578:2003) if applicable 
 N/A 
 
 
 
 
 
 
                                                                            Page 41 of 58                   Report No. JSH006100256-002 
Appendix no. 1 Photos of the product:
 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
External views of EUT 
 
 
 
 
 
 
                                                                            Page 42 of 58                   Report No. JSH006100256-002 
Appendix no. 1 Photos of the product:
 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
 
 
 
      
 
 
 
 
 
Page of 60
Display