Harman Kardon HD 950 (serv.man3) EMC - CB Certificate ▷ View online
Page 19 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
See components list
Pass
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
IP20
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
Not to be connected to the
telecommunication networks
telecommunication networks
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Page 20 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002)
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002)
3.1
Add
the following indent at the end of the list:
- exposure to excessive sound pressures from
headphones or earphones.
headphones or earphones.
NOTE A new method of measurement is described in EN
50332-1, Sound system equipment:
Headphones and earphones associated with portable audio
equipment - Maximum sound pressurelevel measurement
methodology and limit considerations - Part 1: General
method for "one package equipment”, and in EN 50332-2,
Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound
pressure level measurement methodology and limit
considerations - Part 2: Guidelines to associate sets with
headphones coming from different manufacturers.
N/A
4.1.1
Replace
the text of the note by:
NOTE For ROUTINE TEST reference is made to EN 50333.
N/A
5.1.i)
Add
the following note:
NOTE For RATED POWER CONSUMPTION measurements
of TVs reference is made to
EN 60107.
N/A
6.1
Replace
the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions
:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are examples of
adequate locking.
N/A
Page 21 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
6.1
(Cont)
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed
1µSv/h (0,1 mR/h) taking account of the
background level.
background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
A picture is considered to be intelligible if the
following conditions are met:
following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
N/A
13.3.1
Delete note 4.
Pass
14
Delete note 4 and note 5.
Pass
15.1.1
Delete note 1 and note 2.
Pass
15.2
Delete note 2.
Pass
16.1
Delete note 1.
Pass
16.2
Delete the note.
Pass
20
Delete note 2.
Pass
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
N/A
Annex G
Delete the note.
N/A
Annex J.2 Delete the notes of Table J.1
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
50333.
N/A
Page 22 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Biblio-
graphy
graphy
Add
the following standards:
EN 50332-1:2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
prEN 50332-2 (under consideration), Sound system
equipment: Headphones and earphones associated with portable audio
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers
manufacturers
N/A
Add
the following notes for the standards indicated:
IEC 60130
NOTE Parts 9 and 17:1998 are harmonized as ENs (not modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE Harmonized as HD 27 S1:1978 (not modified).
IEC 60335-2-56
NOTE Harmonized as EN 60335-2-56:1997 (not modified)
.
IEC 60335-2-82
NOTE Harmonized as EN 60335-2-82:2000 (not modified)
.
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040:1992 (not modified).
IEC 61558-2-1
NOTE Harmonized as EN 61558-2-1:1997 (not modified).
IEC 61558-2-4
NOTE Harmonized as EN 61558-2-4:1997 (not modified).
IEC 61558-2-6
NOTE Harmonized as EN 61558-2-6:1997 (not modified).
Pass
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
Pass
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N/A