Page 23 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
Pass
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
Pass
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N/A
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT used.
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
Page 24 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such switch used.
N/A
Amendment 1 to EN60065, 7th edition
5.4.1
A warning that batteries (battery pack or batteries
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
N/A
Special stability warning for the apparatus with
CRT
CRT
Warning: the CRT in this product employs a
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
N/A
8.7 Void
N/A
8.8
For requirements for non-separable thin sheet
insulation in two or more layers, see 8.22.
insulation in two or more layers, see 8.22.
N/A
8.22
Requirements for non-separable thin sheet
insulation in two or more layers
insulation in two or more layers
N/A
15.2
Delete the paragraph: In supply apparatus of
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
N/A
18.1
Protective film as part of the implosion protection
system: all edges covered by the enclosure of the
apparatus
system: all edges covered by the enclosure of the
apparatus
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
20.1
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Pass
b) Exemption for small components as defined in
20.1 excluding metal, glass and ceramic.
20.1 excluding metal, glass and ceramic.
Pass
Page 25 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
Pass
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 - 104 20 11.6
HD 950
100 - 181 20 10.8
Normal CD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/0.3W
—
Position of the functional switch (W) ...................... :
On
—
Room temperature t1 (°C) ...................................:
24.0
Room temperature t2 (°C) ...................................:
24.0
Operating conditions
Normal CD playing, with 1/8 non-clipped pink noise output power to the speaker, operates 4 hours until steady
condition reached. Ambient 24
condition reached. Ambient 24
o
C.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 98
11.8
N.A.
90 201
11.0
N.A.
Loudspeaker impedance (Ω) ................................. : 8 Ω X 2
—
Several loudspeaker systems
Internal speakers
--
Marking of loudspeaker terminals
--
--
dT (K)
monitored point:
264
90
Permitted dT (K)
Connector
11.9
10.6
-
Fuse holder
11.4
10.2
-
RV1 16.7
18.7
-
CX1 (X2 capacitor )
17.7
16.0
50 (85-35)
Winding of LF1
17.4
20.9
65*
PCB near D2
20.8
19.6
75
Page 26 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
PCB near IC1
52.3
33.5
75
EC1 (electrolytic capacitor)
18.5
14.6
70 (105-35)
Winding of TR1
23.9
16.7
65*
Bobbin of TR1
21.7
16.1
65
PCB near TR1
20.7
16.5
75
CY1 (Y1 capacitor)
15.0
13.6
50 (85-35)
CY3 (Y1 capacitor)
21.4
17.7
50 (85-35)
PCB near IC3
11.9
10.0
75
PCB near D15
22.8
19.7
75
EC19 (electrolytic capacitor)
15.2
13.3
70 (105-35)
Power cord
10.3
8.8
50
Enclosure (metallic)
9.9
7.5
30
Enclosure (non-metallic)
4.9
3.8
50
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Between parts separated by double or reinforced insulation
100
4
Between parts of TR1 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown