Harman Kardon HD 950 (serv.man3) EMC - CB Certificate ▷ View online

 
                                                                                Page 23 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
         
 N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
         
 N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
 Pass 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
         
 Pass 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
         
 N/A 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
         
 N/A 
 
- protecting rim also tested 
         
 N/A 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
         
 N/A 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 N/A 
 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT used. 
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
         
 N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
         
 N/A 
 
                                                                                Page 24 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
         
 N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
         
 N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
         
 N/A 
 
IT: certification number on the back cover 
         
 N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No such switch used. 
N/A 
 
 
Amendment 1 to EN60065, 7th edition 
 
5.4.1 
A warning that batteries (battery pack or batteries 
installed) shall not be exposed to excessive heat 
such as sunshine, fire or the like. 
 N/A 
 
Special stability warning for the apparatus with 
CRT 
Warning: the CRT in this product employs a 
protective film on the face. This film must not be 
removed as it serves a safety function and removal 
will increase the risk of serious injury. 
 N/A 
8.7 Void 
 
N/A 
8.8 
For requirements for non-separable thin sheet 
insulation in two or more layers, see 8.22. 
 N/A 
8.22 
Requirements for non-separable thin sheet 
insulation in two or more layers 
 N/A 
15.2 
Delete the paragraph:  In supply apparatus of 
Class I with non-hazardous live output voltage: 
output circuit shall not be connected to the 
protective earthing conductor. 
 N/A 
18.1 
Protective film as part of the implosion protection 
system:  all edges covered by the enclosure of the 
apparatus 
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 
20.1 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 Pass 
 
b) Exemption for small components as defined in 
20.1 excluding metal, glass and ceramic. 
 Pass 
 
                                                                                Page 25 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
5.1 
TABLE: rated current/power consumption 
Pass 
 
Model  
Input voltage 
(V) 
Rated 
current 
(mA) 
Measured 
current 
(mA) 
Rated 
power (W) 
Measured 
power (W) 
condition/status 
240 -  104 20  11.6 
HD 950 
100 -  181 20  10.8 
Normal CD playing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by 
0W/0.3W 
— 
 
Position of the functional switch (W) ...................... :
On 
— 
 
Room temperature t1 (°C)  ...................................:
24.0 
 
 
Room temperature t2 (°C)  ...................................:
24.0 
 
 
Operating conditions 
Normal CD playing, with 1/8 non-clipped pink noise output power to the speaker, operates 4 hours until steady 
condition reached. Ambient 24
o
C. 
Un (V) 
In (mA)  
Pn (W)  
Pout (V / mA) 
264 98 
11.8 
N.A. 
90 201 
11.0 
N.A. 
 
         
 
Loudspeaker impedance (Ω) ................................. : 8 Ω X 2 
— 
         
 
Several loudspeaker systems 
Internal speakers 
-- 
         
 
Marking of loudspeaker terminals 
-- 
-- 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
Connector  
11.9 
10.6 
Fuse holder 
11.4 
10.2 
RV1 16.7 
18.7 
CX1 (X2 capacitor ) 
17.7 
16.0 
50 (85-35) 
Winding of LF1 
17.4 
20.9 
65* 
PCB near D2 
20.8 
19.6 
75 
 
                                                                                Page 26 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
PCB near IC1 
52.3 
33.5 
75 
EC1 (electrolytic capacitor) 
18.5 
14.6 
70 (105-35) 
Winding of TR1 
23.9 
16.7 
65* 
Bobbin of TR1 
21.7 
16.1 
65 
PCB near TR1 
20.7 
16.5 
75 
CY1 (Y1 capacitor)  
15.0 
13.6 
50 (85-35) 
CY3 (Y1 capacitor)  
21.4 
17.7 
50 (85-35) 
PCB near IC3 
11.9 
10.0 
75 
PCB near D15 
22.8 
19.7 
75 
EC19 (electrolytic capacitor) 
15.2 
13.3 
70 (105-35) 
Power cord 
10.3 
8.8 
50  
Enclosure (metallic)  
9.9 
7.5 
30  
Enclosure (non-metallic) 
4.9 
3.8 
50 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
100 
Between parts separated by double or reinforced insulation 
100 
Between parts of TR1 separated by basic or supplementary 
insulation 
100 2 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Page of 60