DOWNLOAD Harman Kardon HD 950 (serv.man3) Service Manual ↓ Size: 5.44 MB | Pages: 60 in PDF or view online for FREE

Model
HD 950 (serv.man3)
Pages
60
Size
5.44 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hd-950-sm3.pdf
Date

Harman Kardon HD 950 (serv.man3) EMC - CB Certificate ▷ View online

 
                                                                                Page 11 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
TR1 basic insulation minimum 
5.0 mm between TR1 core 
and primary, Supplementary 
insulation minimum 5.0mm 
between TR1 core and 
secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
TR1 bobbin: 0.8mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
TR1 basic insulation minimum 
5.0 mm between TR1 core 
and primary, Supplementary 
insulation minimum 5.0mm 
between TR1 core and 
secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
TR1 bobbin: 0.8mm min.
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
Pass 
 
Protective devices used within their ratings 
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse FU1: 3.4mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
N/A 
 
                                                                                Page 12 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
FU1 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : FU1: T1A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Only one fuse holder 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
 
 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 Switches 
No 
switch 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
         
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
         
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
         
 N/A 
 
                                                                                Page 13 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
         
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
         
 N/A 
 
Socket outlet current marking correct 
         
 N/A 
14.7 
Safety interlocks 
No such parts 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
         
 N/A 
14.8 
Voltage setting devices 
No such parts 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
         
 N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors 
Only low voltage DC servo 
motor in DVD loader 
N/A 
 
Motor start test 
         
 N/A 
 
Dielectric strength test 
         
 N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
         
 N/A 
14.9.3 
Protection against moving parts 
         
 N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
         
 N/A 
14.10 Batteries 
 Pass 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
Only non-rechargeable alkali 
batteries in IR remote 
controller. 
Pass 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
No recharging circuit in 
apparatus 
N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
No recharging circuit in 
apparatus 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
No lithium battery 
N/A 
14.10.4 
Battery mould stress relief 
No such battery 
N/A 
14.10.5 
Battery drop test 
No such battery 
N/A 
14.11 
Optocouplers 
Separately approved, see 
appended table 
Pass 
 
                                                                                Page 14 of 58                        Report No. JSH006100256-002 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Optocouplers comply with Cl. 8 
Internal DTI >0.40mm
  
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
int./ext. Cl. &Cr. >4mm / 
≥6.0mm 
Pass 
14.12 
Surge suppression varistors 
VDE approved 
Pass 
 
Comply with IEC 61051-2 
 
Pass 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 Pass 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Mains plug approved 
Pass 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets 
 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
         
 N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II 
N/A 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A ................... :  
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 Pass 
Page of 60
Display