Harman Kardon HD 950 (serv.man3) EMC - CB Certificate ▷ View online
Page 35 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Tube of TR1
GREAT
HOLDING
INDUSTRIAL CO
LTD
PTFE tube:TFL 200℃, VW-1
IEC 60065
UL: E156256
and tested
with appliance
and tested
with appliance
(alternative) CHANGYUAN
ELECTRONICS(
SHENZHEN)
PTFE CB-TT
200℃, VW-1
IEC 60065
UL: E180908
and tested
with appliance
Plastic shell
CHI MEI
CORPORATION.
PA-764(+) Thickness
min.
1.5mm, V-0,
75℃
IEC60695-11-10 UL:
E56070
and tested
with appliance
with appliance
Fuse holder
CHI MEI
CORPORATION
PA-764(+)
Thickness min.
1.5mm, V-0,
75℃
IEC60695-11-10 UL:
E56070
and tested
with appliance
with appliance
Varistor Lien
Shun
Technical Co.
Ltd.
10D471K -
IEC 61051-2
VDE:
40005858
and tested
with appliance
40005858
and tested
with appliance
(alternative) Xianhua
Advanced
Sensitive
Components Co.,
Ltd
FNR-10K471 -
IEC 61051-2
VDE:
40008242
and tested
with appliance
40008242
and tested
with appliance
Laser pickup unit SANYO Electric
Co., Ltd
SF-HD65
CD mode:
134μW,
DVD mode:
173μW
IEC60825-1 Tested
with
appliance
Laser diodes
TOSHIBA
CORPORATION
TOLD2000FDA
TOLD2000MDA
650nm(DVD)
790nm(CD)
IEC60825-1 Tested
with
appliance
Page 36 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
PCB
FUJIAN ERLING
ELECTRONICS
CO LTD
FB1A
FB-4
FV0, 105℃
1.4mm min,
IEC60695-11-10 UL:
E148234
and tested
with appliance
with appliance
(alternative) China
Circuit
Technology
(Shantou) Corp.
4
3
2
FV0, 105℃
1.4mm min,
IEC60695-11-10 UL:
E99006
and tested
with appliance
with appliance
(alternative) SHENZHEN
HUAFA CIRCUIT
FACTORY
HF-1
HF-D
FV0, 130℃
1.4mm min
IEC60695-11-10 UL:
E221166
and tested
with appliance
with appliance
(alternative) CALI-TECH
ELECTRONICS
CO LTD
CT-101
CT-102
FV0, 130℃
1.4mm min
IEC60695-11-10 UL:
E216635
and tested
with appliance
with appliance
(alternative) SHENZHEN
TONGXIN
CIRCUIT
ELECTRONICS
CO LTD
TY-01
TY-11
FV0, 130℃
1.4mm min
IEC60695-11-10 UL:
E201362
and tested
with appliance
with appliance
(alternative) LUKS
ELECTRICAL
APPLIANCE
MFY LTD
LK-D-26-V0
FV0, 130℃
1.4mm min
IEC60695-11-10 UL:
E78613
and tested
with appliance
with appliance
(alternative)
E CITY P C B CO
LTD
EC-2
EC-3
FV-0, 130
°C
IEC60695-11-10 UL:
E188100
and tested
with appliance
with appliance
(alternative) SUN
HUNG
(ZHUHAI)
ELECTRONICS
TECHNOLOGY
CO LTD
SHDS01
FV-0, 130
°C
IEC60695-11-10 UL:
E228944
and tested
with appliance
with appliance
Page 37 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
(alternative) XING
DA
PRINTED
CIRCUIT BOARD
MFR CO LTD
XD-102
FV-0, 130
°C
IEC60695-11-10 UL:
E193079
and tested
with appliance
with appliance
(alternative) MILLION
SOURCES CO
LTD HK
MS-1
FV-0, 130
°C
IEC60695-11-10 UL:
E198407
and tested
with appliance
with appliance
(alternative) BRAIN
POWER
CO
ML
FV-0, 105
°C
IEC60695-11-10 UL:
E186014
and tested
with appliance
with appliance
Insulation Sheet
GENERAL
ELECTRIC CO
FR1(E)(GG) Thickness:
0.51mm
FV0, 120℃
IEC 60065
UL: E61257
and tested
with appliance
and tested
with appliance
Connector
MOLEX INC
35977
35979
--
IEC 60065
UL: E29179
and tested
with appliance
and tested
with appliance
National differences for CHINA
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
4.2.1 first sentence replaced by:
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
Pass
5.1f
)
Second paragraph replaced by:
………When single rated voltage is given, it
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
Pass
5.4 replaced by
:
When information with regard to safety is
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
Pass
Page 38 of 58 Report No. JSH006100256-002
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
15.1.1 first sentence replaced by:
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Pass
National differences for KOREA
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
5.101
Other marking ; Wording "____ “ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
Pass
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
Pass
National differences for SINGAPORE
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 110A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
Throughout the standard
, whenever the words “white pine board” appear, insert
the words “or plywood board” to it.
Pass
SS 143 Amendment No.1 and No. 2
4.1.3
Delete “45 % to 75 %” and insert “65 _ 5 %”.
75% maximum in IEC
60065:2001
60065:2001
Pass
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
conditions.
Adopt the temperature specified for the tropical
conditions.
Pass
9.3.4
Delete the note “A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
This is not in IEC 60065:2001.
Pass
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
Pass
16
External flexible cords
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Pass