<12007721 001> 
 
 
Page 35 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
4.5.2 
Resistance to abnormal heat 
Phenolic bobbin material is 
used in transformer (T1) which 
accepted without test. 
 
4.6 
Openings in enclosures
 
4.6.1 
Top and side openings 
No top and side opening. 
 
Dimensions (mm)  ................................................:   
 
4.6.2 
Bottoms of fire enclosures 
No bottom openings. 
 
Construction of the bottom ...................................:   
 
4.6.3 
Doors or covers in fire enclosures 
No door or cover. 
4.6.4 
Openings in transportable equipment 
 
4.6.5 
Adhesives for constructional purposes 
 
 
Conditioning temperature/time ................................  
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame  Use of materials with the 
required flammability classes. 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
With having the following 
parts: 
· 
components in primary 
· 
components in secondary 
(not supplied by LPS) 
· 
components having 
unenclosed arcing parts at 
hazardous voltage or 
energy level 
· 
insulated wiring  
the fire enclosure is required. 
4.7.2.2 
Parts not requiring a fire enclosure 
 
4.7.3 
Materials 
4.7.3.1 
General 
See appended tabel 1.5.1 for 
PCB. 
4.7.3.2 
Materials for fire enclosures 
See appended tabel 1.5.1 for 
enclosure material. 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
No components outside fire 
enclosure. 
 
 
<12007721 001> 
 
 
Page 36 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
4.7.3.4 
Materials for components and other parts inside 
fire enclosures 
Internal components except 
small parts are V-2 or better. 
4.7.3.5 
Materials for air filter assemblies 
No air filter assemblies. 
4.7.3.6 
Materials used in high-voltage components 
No high voltage components 
provided. 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
5.1 
Touch current and protective conductor current 
5.1.1 
General 
See sub-clauses 5.1.2 to 
5.1.6. 
5.1.2 
Equipment under test (EUT) 
EUT has only one mains 
connection. 
5.1.3 
Test circuit 
Using figure 5A. 
5.1.4 
Application of measuring instrument 
Using measuring instrument 
in annex D. 
5.1.5 
Test procedure 
The touch current was 
measured from primary to 
conductive parts (secondary 
o/p) and plastic enclosure with 
metal foil (dimension: 10cm X 
20cm) 
5.1.6 
Test measurements 
See below. 
 
Test voltage (V)  ...................................................:  See appended table 5.1.6. 
 
 
Measured current (mA) ........................................:  See appended table 5.1.6. 
 
 
Max. allowed current (mA) ...................................:  See appended table 5.1.6. 
 
5.1.7 
Equipment with touch current exceeding 3.5 mA   
..............................................................................: 
 
5.1.8 
Touch currents to and from telecommunication 
networks 
No TNV. 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network 
Ditto 
 
Test voltage (V)  ...................................................:  Ditto 
 
 
Measured current (mA) ........................................:  Ditto 
 
 
Max. allowed current (mA) ...................................:  Ditto 
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks ................................: 
No TNV. 
 
5.2 
Electric strength 
5.2.1 
General 
See appended table 5.2. 
 
 
<12007721 001> 
 
 
Page 37 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
5.2.2 
Test procedure  
Ditto. 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
Result see appended table 
5.3. 
5.3.2 
Motors 
No motor used. 
5.3.3 
Transformers 
With the shorted output of the 
transformers, no high temp. of 
the transformer are to be 
observed or to be expected. 
Result of the short tests see 
5.3 appended table and Annex 
C. 
5.3.4 
Functional insulation .............................................:  By short-circuited, test results 
see appended table 5.3. 
5.3.5 
Electromechanical components 
No electromechanical 
component. 
5.3.6 
Simulation of faults 
Results see appended table. 
5.3.7 
Unattended equipment 
None of the listed components 
was provided. 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
No molten metal was emitted. 
Electric strength test primary 
to outside enclosure and 
primary to SELV were passed. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
 
6.1 
Protection of telecommunication network service personnel, and users of other 
equipment connected to the network, from hazards in the equipment 
6.1.1 
Protection from hazardous voltages 
6.1.2 
Separation of the telecommunication network from earth 
6.1.2.1 
Requirements 
 
 
Test voltage (V)  ...................................................:   
 
 
Current  in the test circuit  (mA) ...........................:   
 
6.1.2.2 
Exclusions.............................................................:   
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
6.2.1 
Separation requirements 
 
6.2.2 
Electric strength test procedure 
 
 
 
<12007721 001> 
 
 
Page 38 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
6.2.2.1 
Impulse test 
 
6.2.2.2 
Steady-state test 
 
6.2.2.3 
Compliance criteria 
 
 
6.3 
Protection of telecommunication wiring system from overheating 
 
Max. output current (A).........................................:   
 
 
Current limiting method ........................................:   
 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
A.1 
Flammability test for fire enclosures of movable equipment having a total mass 
exceeding 18 kg, and of stationary equipment (see 4.7.3.2) 
A.1.1 
Samples 
 
 
 
Wall thickness (mm) ............................................:   
 
A.1.2 
Conditioning of samples; temperature (
°
C)..........:   
A.1.3 
Mounting of samples ............................................:   
A.1.4 
Test flame 
 
A.1.5 
Test procedure 
 
A.1.6 
Compliance criteria 
 
 
Sample 1 burning time (s)....................................:   
 
 
Sample 2 burning time (s)....................................:   
 
 
Sample 3 burning time (s)....................................:   
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass 
not exceeding 18 kg, and for material and components located inside fire 
enclosures (see 4.7.3.2 and 4.7.3.4) 
UL approved material used. No further tests were considered.
 
A.2.1 
Samples 
 
 
 
Wall thickness (mm) ............................................:   
 
A.2.6 
Compliance criteria 
 
 
Sample 1 burning time (s)....................................:   
 
 
Sample 2 burning time (s)....................................:   
 
 
Sample 3 burning time (s)....................................:   
 
A.2.7 
Alternative test acc. to IEC 60695-2-2, cl. 4, 8 
 
 
Sample 1 burning time (s)....................................:   
 
 
Sample 2 burning time (s)....................................:   
 