Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online
<12007721 001>
Page 35 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
4.5.2
Resistance to abnormal heat
Phenolic bobbin material is
used in transformer (T1) which
accepted without test.
P
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No top and side opening.
P
Dimensions (mm) ................................................:
4.6.2
Bottoms of fire enclosures
No bottom openings.
P
Construction of the bottom ...................................:
4.6.3
Doors or covers in fire enclosures
No door or cover.
N
4.6.4
Openings in transportable equipment
N
4.6.5
Adhesives for constructional purposes
N
Conditioning temperature/time ................................
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame Use of materials with the
required flammability classes.
P
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
With having the following
parts:
·
·
components in primary
·
components in secondary
(not supplied by LPS)
·
components having
unenclosed arcing parts at
hazardous voltage or
energy level
·
insulated wiring
the fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
N
4.7.3
Materials
P
4.7.3.1
General
See appended tabel 1.5.1 for
PCB.
P
4.7.3.2
Materials for fire enclosures
See appended tabel 1.5.1 for
enclosure material.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
No components outside fire
enclosure.
N
<12007721 001>
Page 36 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
4.7.3.4
Materials for components and other parts inside
fire enclosures
Internal components except
small parts are V-2 or better.
P
4.7.3.5
Materials for air filter assemblies
No air filter assemblies.
N
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
N
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
See sub-clauses 5.1.2 to
5.1.6.
P
5.1.2
Equipment under test (EUT)
EUT has only one mains
connection.
P
5.1.3
Test circuit
Using figure 5A.
P
5.1.4
Application of measuring instrument
Using measuring instrument
in annex D.
P
5.1.5
Test procedure
The touch current was
measured from primary to
conductive parts (secondary
o/p) and plastic enclosure with
metal foil (dimension: 10cm X
20cm)
P
5.1.6
Test measurements
See below.
P
Test voltage (V) ...................................................: See appended table 5.1.6.
Measured current (mA) ........................................: See appended table 5.1.6.
Max. allowed current (mA) ...................................: See appended table 5.1.6.
5.1.7
Equipment with touch current exceeding 3.5 mA
..............................................................................:
N
5.1.8
Touch currents to and from telecommunication
networks
No TNV.
N
5.1.8.1
Limitation of the touch current to a
telecommunication network
Ditto
N
Test voltage (V) ...................................................: Ditto
Measured current (mA) ........................................: Ditto
Max. allowed current (mA) ...................................: Ditto
5.1.8.2
Summation of touch currents from
telecommunication networks ................................:
No TNV.
N
5.2
Electric strength
P
5.2.1
General
See appended table 5.2.
P
<12007721 001>
Page 37 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
5.2.2
Test procedure
Ditto.
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
Result see appended table
5.3.
P
5.3.2
Motors
No motor used.
N
5.3.3
Transformers
With the shorted output of the
transformers, no high temp. of
the transformer are to be
observed or to be expected.
Result of the short tests see
Result of the short tests see
5.3 appended table and Annex
C.
P
5.3.4
Functional insulation .............................................: By short-circuited, test results
see appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component.
N
5.3.6
Simulation of faults
Results see appended table.
P
5.3.7
Unattended equipment
None of the listed components
was provided.
N
5.3.8
Compliance criteria for abnormal operating and
fault conditions
No molten metal was emitted.
Electric strength test primary
to outside enclosure and
primary to SELV were passed.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N
6.1
Protection of telecommunication network service personnel, and users of other
equipment connected to the network, from hazards in the equipment
N
6.1.1
Protection from hazardous voltages
N
6.1.2
Separation of the telecommunication network from earth
N
6.1.2.1
Requirements
N
Test voltage (V) ...................................................:
Current in the test circuit (mA) ...........................:
6.1.2.2
Exclusions.............................................................:
N
6.2
Protection of equipment users from overvoltages on telecommunication networks
N
6.2.1
Separation requirements
N
6.2.2
Electric strength test procedure
N
<12007721 001>
Page 38 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
6.2.2.1
Impulse test
N
6.2.2.2
Steady-state test
N
6.2.2.3
Compliance criteria
N
6.3
Protection of telecommunication wiring system from overheating
N
Max. output current (A).........................................:
Current limiting method ........................................:
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
P
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N
A.1.1
Samples
Wall thickness (mm) ............................................:
A.1.2
Conditioning of samples; temperature (
°
C)..........:
N
A.1.3
Mounting of samples ............................................:
N
A.1.4
Test flame
N
A.1.5
Test procedure
N
A.1.6
Compliance criteria
N
Sample 1 burning time (s)....................................:
Sample 2 burning time (s)....................................:
Sample 3 burning time (s)....................................:
A.2
Flammability test for fire enclosures of movable equipment having a total mass
not exceeding 18 kg, and for material and components located inside fire
enclosures (see 4.7.3.2 and 4.7.3.4)
UL approved material used. No further tests were considered.
P
A.2.1
Samples
Wall thickness (mm) ............................................:
A.2.6
Compliance criteria
N
Sample 1 burning time (s)....................................:
Sample 2 burning time (s)....................................:
Sample 3 burning time (s)....................................:
A.2.7
Alternative test acc. to IEC 60695-2-2, cl. 4, 8
N
Sample 1 burning time (s)....................................:
Sample 2 burning time (s)....................................: