DOWNLOAD Harman Kardon GO AND PLAY (serv.man2) Service Manual ↓ Size: 2.53 MB | Pages: 115 in PDF or view online for FREE

Model
GO AND PLAY (serv.man2)
Pages
115
Size
2.53 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm2.pdf
Date

Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 19 of 102 
 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
Output ratings (DC) 
Model Designation 
mA 
Transformer 
Model No. 
Fuse (F2) 
Current Rating 
S60-290160-WZL 
29 
1600 
46.4 
T51969E 
3.15 A 
S60-290170-WZL 
29 
1700 
49.3 
T51969E 
3.15 A 
S60-290180-WZL 
29 
1800 
52.2 
T51969E 
3.15 A 
S60-290190-WZL 
29 
1900 
55.1 
T51969E 
3.15 A 
S60-290200-WZL 
29 
2000 
58 
T51969E 
3.15 A 
S60-290207-WZL 
29 
2070 
60 
T51969E 
3.15 A 
S60-300133-WZL 
30 
1330 
40 
T51969E 
3.15 A 
S60-300140-WZL 
30 
1400 
42 
T51969E 
3.15 A 
S60-300150-WZL 
30 
1500 
45 
T51969E 
3.15 A 
S60-300160-WZL 
30 
1600 
48 
T51969E 
3.15 A 
S60-300170-WZL 
30 
1700 
51 
T51969E 
3.15 A 
S60-300180-WZL 
30 
1800 
54 
T51969E 
3.15 A 
S60-300190-WZL 
30 
1900 
57 
T51969E 
3.15 A 
S60-300200-WZL 
30 
2000 
60 
T51969E 
3.15 A 
S60-310129-WZL 
31 
1290 
40 
T51969E 
3.15 A 
S60-310130-WZL 
31 
1300 
40.3 
T51969E 
3.15 A 
S60-310140-WZL 
31 
1400 
43.4 
T51969E 
3.15 A 
S60-310150-WZL 
31 
1500 
46.5 
T51969E 
3.15 A 
S60-310160-WZL 
31 
1600 
49.6 
T51969E 
3.15 A 
S60-310170-WZL 
31 
1700 
52.7 
T51969E 
3.15 A 
S60-310180-WZL 
31 
1800 
55.8 
T51969E 
3.15 A 
S60-310190-WZL 
31 
1900 
58.9 
T51969E 
3.15 A 
S60-310193-WZL 
31 
1930 
60 
T51969E 
3.15 A 
S60-320125-WZL 
32 
1250 
40 
T51969E 
3 A 
S60-320130-WZL 
32 
1300 
41.6 
T51969E 
3 A 
S60-320140-WZL 
32 
1400 
44.8 
T51969E 
3 A 
S60-320150-WZL 
32 
1500 
48 
T51969E 
3 A 
S60-320160-WZL 
32 
1600 
51.2 
T51969E 
3 A 
S60-320170-WZL 
32 
1700 
54.4 
T51969E 
3 A 
S60-320180-WZL 
32 
1800 
57.6 
T51969E 
3 A 
S60-320187-WZL 
32 
1870 
60 
T51969E 
3 A 
 
 
 
<12007721 001> 
 
 
Page 20 of 102 
 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
Copy of marking plate(s): 
 
 
 
 
 
 
 
 
<12007721 001> 
 
 
Page 21 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
GENERAL 
1.5 
Components 
1.5.1 
Comply with IEC 60950 or relevant component 
standard 
Components which were 
found to affect safety aspects 
comply with the requirements 
of this standard or within the 
safety aspects of the relevant 
IEC component standards. 
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
Components which are 
certified to IEC and /or 
national standards are used 
correctly within their ratings. 
Components not covered by 
IEC standards are tested 
under the conditions present 
in the equipment. 
 
Dimensions (mm) of mains plug for direct plug-in :  Not direct plug in type. 
 
Torque and pull test of mains plug for direct 
plug-in; torque (Nm); pull (N) ................................: 
 
1.5.3 
Thermal controls 
 
1.5.4 
Transformers 
Transformer used is suitable 
for its intended application and 
comply with the relevant 
requirements of the standard 
and particularly Annex C. 
1.5.5 
Interconnecting cables 
Interconnection o/p cable to 
other device is carrying only 
SELV on an energy level 
below 240VA. 
 Except the insulation 
material, there are no further 
requirements to the o/p 
interconnection cable. 
1.5.6 
Capacitors in primary circuits ............................... :  Between lines: X2 capacitor 
according to IEC 60384-
14:1993 with 21 days damp 
heat test. 
1.5.7 
Double or reinforced insulation bridged by 
components 
See below. 
1.5.7.1 
Bridging capacitors 
Primary and secondary 
bridged by one capacitor 
(CY2), which used was 
certified as Y1 capacitor 
according to IEC 60384-
14/1993. 
 
 
<12007721 001> 
 
 
Page 22 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.5.7.2 
Bridging resistors 
No bridging resistors. 
1.5.7.3 
Accessible parts 
See 2.4. 
1.5.8 
Components in equipment for IT power systems 
Class II equipment.  
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
TN power system. IT power 
system for Norway. 
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
the operation with the max. 
specified DC-load.  
Results see appended table 
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not a hand-
held equipment. 
1.6.4 
Neutral conductor  
Class II equipment. Phase 
conductors separated to body 
by reinforced insulation. 
 
1.7 
Marking and instructions 
1.7.1 
Power rating  
See below. 
 
Rated voltage(s) or voltage range(s) (V)  .............:  AC 100-240V~ 
 
Symbol for nature of supply for d.c.  .....................:  Mains from AC source 
 
Rated frequency or frequency range (Hz) ............:  47-63Hz 
 
Rated current (A)  .................................................:  2A MAX. 
 
Manufacturer’s name/Trademark  ........................:  SPEC LIN 
 
Type/model  ..........................................................:  S60-XXXYYY-WZ, S60-
XXXYYY-WZL 
(XXX= 090-320, YYY=125-
500, Z = H01-H99) 
 
Symbol of Class II ................................................:  Double square symbol 
provided. 
 
Other symbols ......................................................:  Additional symbols or marking 
does not give rise to 
misunderstanding. 
 
Certification marks ...............................................:  See the copy of marking 
plate. 
1.7.2 
Safety instructions 
User’s manual provided.  
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
Page of 115
Display