Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 31 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
3.1.10 
Sleeving on wiring 
No sleeves used as 
supplementary insulation. 
 
3.2 
Connection to a.c. mains supplies 
 
3.2.1 
Means of connection  
Appliance inlet. 
3.2.2 
Multiple supply connections  
Only one supply connector. 
3.2.3 
Permanently connected equipment 
Appliance inlet provided, not a 
permanently connected 
equipment. 
 
Number of conductors, diameter (mm) of cable 
and conduits  ........................................................: 
 
 
3.2.4 
Appliance inlets 
The appliance inlet complies 
with IEC 60320-1. The power 
cord can be inserted without 
difficulties and does not 
support the unit. 
3.2.5 
Power supply cords  
No power cord provided. 
Statement in the user’s 
manual that a certified power 
cord with gauge of 0.75mm
2
 
shall be used. 
 
Type......................................................................:   
 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG .....................................................................: 
 
 
3.2.6 
Cord anchorages and strain relief 
 
 
Mass of equipment (kg), pull (N)   ........................:   
 
 
Longitudinal displacement (mm) ..........................:   
 
3.2.7 
Protection against mechanical damage 
No parts under this unit likely 
to damage the power supply 
cord. No sharp edge. 
3.2.8 
Cord guards 
No cord guard. 
 
D (mm); test mass (g) ..........................................:  Ditto 
 
 
Radius of curvature of cord (mm).........................:  Ditto 
 
3.2.9 
Supply wiring space 
Equipment not for permanent 
connection or for connection of 
ordinary non-detachable 
power supply cord. 
 
3.3 
Wiring terminals for connection of external conductors 
Appliance inlet provided, no wiring terminal for connection of external conductors.
 
 
 
<12007721 001> 
 
 
Page 32 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
3.3.1 
Wiring terminals 
 
3.3.2 
Connection of non-detachable power supply cords   
3.3.3 
Screw terminals 
 
3.3.4 
Rated current (A), cord/cable type, cross-
sectional area (mm
2
)............................................. : 
 
3.3.5 
Rated current (A), type and nominal thread 
diameter (mm) ...................................................... : 
 
3.3.6 
Wiring terminals design 
 
3.3.7 
Grouping of wiring terminals 
 
3.3.8 
Stranded wire 
 
 
3.4 
Disconnection from the a.c. mains supply 
3.4.1 
General requirement 
Disconnect device provided. 
3.4.2 
Disconnect devices 
Appliance inlet. 
3.4.3 
Permanently connected equipment 
Not a permanently connected 
equipment. 
3.4.4 
Parts which remain energized 
When plug or inlet is 
disconnected no remaining 
parts with hazardous voltage 
in the equipment 
3.4.5 
Switches in flexible cords 
No switch used. 
3.4.6 
Single-phase equipment 
The power cord plug or inlet 
disconnects both poles 
simultaneously. 
3.4.7 
Three-phase equipment 
Single phase. 
3.4.8 
Switches as disconnect devices 
No switch used. 
3.4.9 
Plugs as disconnect devices 
Appliance inlet used. 
3.4.10 
Interconnected equipment 
Interconnection to other 
devices by secondary output 
cable only. 
3.4.11 
Multiple power sources 
Only one supply connection 
provided. 
 
3.5 
Interconnection of equipment
 
3.5.1 
General requirements 
See below. 
3.5.2 
Types of interconnection circuits ..........................:  Interconnection circuits of 
SELV through sec o/p cable. 
No ELV interconnection 
circuits.  
 
 
<12007721 001> 
 
 
Page 33 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnection. 
 
PHYSICAL REQUIREMENTS 
4.1 
Stability 
 
Angle of 10
°
 
No overbalancing due to 
equipment design (length and 
width exceed the height by 
far). 
 
Test: force (N).......................................................:   
 
4.2 
Mechanical strength 
4.2.1 
General 
See below. After tests, unit 
comply with 2.1.1 and 2.10. 
4.2.2 
Steady force test, 10 N 
10N applied to components 
other than parts serving as an 
enclosure. 
4.2.3 
Steady force test, 30 N 
 
4.2.4 
Steady force test, 250 N 
 
 
         250N applied to outer 
enclosure. No energy or other 
hazards. 
4.2.5 
Impact test 
No hazard as result from steel 
sphere ball impact test. 
4.2.6 
Drop test 
 
4.2.7 
Stress relief 
After 7 hours at 82.0
°
C and 
cooling down to room 
temperature, no shrinkage , 
distortion or loosening any 
enclosure part was noticeable 
on the equipment.  
4.2.8 
Cathode ray tubes 
No cathode ray tube. 
 
Picture tube separately certified ........................... :   
4.2.9 
High pressure lamps 
No high pressure lamps. 
4.2.10 
Wall or ceiling mounted equipment; force (N)  ... :   
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
Edges and corners of the 
enclosure are rounded. 
4.3.2 
Handles and manual controls; force (N)...............:  No handles or controls 
provided. 
 
 
<12007721 001> 
 
 
Page 34 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
4.3.3 
Adjustable controls  
No adjustable controls. 
4.3.4 
Securing of parts 
No connection likely to be 
exposed to mechanical stress 
are provided in unit. 
4.3.5 
Connection of plugs and sockets 
No mismatching of connector, 
plug or socket possible. IEC 
60083 and IEC 60320 
connectors are not used in 
SELV. 
4.3.6 
Direct plug-in equipment 
Not direct plug-in type. 
 
Torque (Nm) .........................................................:  Ditto 
 
4.3.7 
Heating elements in earthed equipment 
No heating element. 
4.3.8 
Batteries 
No battery. 
4.3.9 
Oil and grease 
Equipment in intended use not 
considered to be exposed to 
these. 
4.3.10 
Dust, powders, liquids and gases 
The equipment in intended 
use not considered to be 
exposed to dust, powers, 
liquids and gases. 
4.3.11 
Containers for liquids or gases 
No container for liquid or gas. 
4.3.12 
Flammable liquids.................................................:  No flammable liquid. 
 
Quantity of liquid (l)...............................................:  Ditto 
 
Flash point (
°
C).....................................................:  Ditto 
4.3.13 
Radiation; type of radiation  ..................................:  The LED energy is far below 
the limit of LED class 1. 
 
Equipment using lasers 
 
 
4.4 
Protection against hazardous moving parts
 
4.4.1 
General 
No moving parts used. 
4.4.2 
Protection in operator access areas 
 
4.4.3 
Protection in restricted access locations  
 
4.4.4 
Protection in service access areas 
 
 
4.5 
Thermal requirements 
4.5.1 
Temperature rises 
See appended table 4.5.1. 
 
Normal load condition per Annex L......................:  See 1.6.2. 
Page of 115