Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online
<12007721 001>
Page 31 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
3.1.10
Sleeving on wiring
No sleeves used as
supplementary insulation.
N
3.2
Connection to a.c. mains supplies
P
3.2.1
Means of connection
Appliance inlet.
P
3.2.2
Multiple supply connections
Only one supply connector.
N
3.2.3
Permanently connected equipment
Appliance inlet provided, not a
permanently connected
equipment.
N
Number of conductors, diameter (mm) of cable
and conduits ........................................................:
3.2.4
Appliance inlets
The appliance inlet complies
with IEC 60320-1. The power
cord can be inserted without
difficulties and does not
support the unit.
P
3.2.5
Power supply cords
No power cord provided.
Statement in the user’s
manual that a certified power
cord with gauge of 0.75mm
2
shall be used.
N
Type......................................................................:
Rated current (A), cross-sectional area (mm
2
),
AWG .....................................................................:
3.2.6
Cord anchorages and strain relief
N
Mass of equipment (kg), pull (N) ........................:
Longitudinal displacement (mm) ..........................:
3.2.7
Protection against mechanical damage
No parts under this unit likely
to damage the power supply
cord. No sharp edge.
N
3.2.8
Cord guards
No cord guard.
N
D (mm); test mass (g) ..........................................: Ditto
Radius of curvature of cord (mm).........................: Ditto
3.2.9
Supply wiring space
Equipment not for permanent
connection or for connection of
ordinary non-detachable
power supply cord.
N
3.3
Wiring terminals for connection of external conductors
Appliance inlet provided, no wiring terminal for connection of external conductors.
N
<12007721 001>
Page 32 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
3.3.1
Wiring terminals
N
3.3.2
Connection of non-detachable power supply cords
N
3.3.3
Screw terminals
N
3.3.4
Rated current (A), cord/cable type, cross-
sectional area (mm
2
)............................................. :
N
3.3.5
Rated current (A), type and nominal thread
diameter (mm) ...................................................... :
N
3.3.6
Wiring terminals design
N
3.3.7
Grouping of wiring terminals
N
3.3.8
Stranded wire
N
3.4
Disconnection from the a.c. mains supply
P
3.4.1
General requirement
Disconnect device provided.
P
3.4.2
Disconnect devices
Appliance inlet.
P
3.4.3
Permanently connected equipment
Not a permanently connected
equipment.
N
3.4.4
Parts which remain energized
When plug or inlet is
disconnected no remaining
parts with hazardous voltage
in the equipment
P
3.4.5
Switches in flexible cords
No switch used.
N
3.4.6
Single-phase equipment
The power cord plug or inlet
disconnects both poles
simultaneously.
P
3.4.7
Three-phase equipment
Single phase.
N
3.4.8
Switches as disconnect devices
No switch used.
N
3.4.9
Plugs as disconnect devices
Appliance inlet used.
N
3.4.10
Interconnected equipment
Interconnection to other
devices by secondary output
cable only.
N
3.4.11
Multiple power sources
Only one supply connection
provided.
N
3.5
Interconnection of equipment
P
3.5.1
General requirements
See below.
P
3.5.2
Types of interconnection circuits ..........................: Interconnection circuits of
SELV through sec o/p cable.
No ELV interconnection
circuits.
P
<12007721 001>
Page 33 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection.
N
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
P
Angle of 10
°
No overbalancing due to
equipment design (length and
width exceed the height by
far).
P
Test: force (N).......................................................:
N
4.2
Mechanical strength
P
4.2.1
General
See below. After tests, unit
comply with 2.1.1 and 2.10.
P
4.2.2
Steady force test, 10 N
10N applied to components
other than parts serving as an
enclosure.
P
4.2.3
Steady force test, 30 N
N
4.2.4
Steady force test, 250 N
250N applied to outer
enclosure. No energy or other
hazards.
P
4.2.5
Impact test
No hazard as result from steel
sphere ball impact test.
P
4.2.6
Drop test
N
4.2.7
Stress relief
After 7 hours at 82.0
°
C and
cooling down to room
temperature, no shrinkage ,
distortion or loosening any
enclosure part was noticeable
on the equipment.
P
4.2.8
Cathode ray tubes
No cathode ray tube.
N
Picture tube separately certified ........................... :
N
4.2.9
High pressure lamps
No high pressure lamps.
N
4.2.10
Wall or ceiling mounted equipment; force (N) ... :
N
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N)...............: No handles or controls
provided.
N
<12007721 001>
Page 34 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
4.3.3
Adjustable controls
No adjustable controls.
N
4.3.4
Securing of parts
No connection likely to be
exposed to mechanical stress
are provided in unit.
P
4.3.5
Connection of plugs and sockets
No mismatching of connector,
plug or socket possible. IEC
60083 and IEC 60320
connectors are not used in
SELV.
P
4.3.6
Direct plug-in equipment
Not direct plug-in type.
N
Torque (Nm) .........................................................: Ditto
4.3.7
Heating elements in earthed equipment
No heating element.
N
4.3.8
Batteries
No battery.
N
4.3.9
Oil and grease
Equipment in intended use not
considered to be exposed to
these.
N
4.3.10
Dust, powders, liquids and gases
The equipment in intended
use not considered to be
exposed to dust, powers,
liquids and gases.
N
4.3.11
Containers for liquids or gases
No container for liquid or gas.
N
4.3.12
Flammable liquids.................................................: No flammable liquid.
N
Quantity of liquid (l)...............................................: Ditto
N
Flash point (
°
C).....................................................: Ditto
N
4.3.13
Radiation; type of radiation ..................................: The LED energy is far below
the limit of LED class 1.
P
Equipment using lasers
N
4.4
Protection against hazardous moving parts
N
4.4.1
General
No moving parts used.
N
4.4.2
Protection in operator access areas
N
4.4.3
Protection in restricted access locations
N
4.4.4
Protection in service access areas
N
4.5
Thermal requirements
P
4.5.1
Temperature rises
See appended table 4.5.1.
P
Normal load condition per Annex L......................: See 1.6.2.
P
Click on the first or last page to see other GO AND PLAY (serv.man2) service manuals if exist.