Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 43 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
Separate test report 
Certified triple insulation wire 
used. 
 
 
<12007721 001> 
 
 
Page 44 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
 
SPECIAL NATIONAL CONDITIONS AND NATIONAL DEVIATIONS 
S = 
Special National Condition, 
A = 
National Deviation (A-deviation), 
C = 
CENELEC Common 
Modification, 
F = 
other information
 
 
C: delete all the "country" notes that appear on the 
following pages of the reference document 
(IEC 60950:1999): 85, 91, 99, 103, 117, 119, 123, 
125, 149, 171, 213, 215, 219, 251, 283, 325, 327, 
331, 333 and 407 
Class II equipment. 
1.2.4.1 
S (DK): certain types of Class I appliances (see 
subclause 3.2.1) may be provided with a plug not 
establishing earthing continuity when inserted into 
Danish socket-outlets 
Class II equipment. 
1.5.1 
A (CH, SE): add the following: 
NOTE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed 
No such switch. 
1.5.8 
S (NO): due to the IT power system used (see 
annex V, figure V.7), capacitors are required to be 
rated for the applicable phase-to phase voltage 
(230 V) 
Considered, see report IEC 
60950. 
1.7.2 
S (NO): class I pluggable equipment type A 
intended for connection to other equipment or a 
communication network shall, if safety relies on 
connection to protective earth, require a marking 
stating that the equipment must be connected to 
an earthed mains socket outlet 
Class II equipment. 
 
S (SE): if the separation between the mains and  
SELV terminal relies upon connection to the 
safety earth, the apparatus shall have a marking 
stating that it must be connected to an earthed 
mains socket-outlet.  
The marking text shall be in Swedish and as 
follows: "Apparaten skall anslutas till jordat uttag 
när den ansluts till ett nätverk." 
Class II equipment. 
 
A (DK): supply cords of Class I equipment, which 
are delivered without a plug must be provided with 
a visible tag with the following text: 
"Vigtigt! Lederen med grøn/gul isolation må kun 
tilsluttes en klemme mærket  
 
 
(IEC 417, No. 5019 eller IEC 417, No. 5017)." 
If essential for the safety of the equipment, the tag 
must in addition be provided with a diagram, 
which shows the connection of the other 
conductors, or be provided with the following text: 
"For tilslutning af de øvrige ledere, se 
medfølgende installationsvejledning." 
Class II equipment. 
 
 
<12007721 001> 
 
 
Page 45 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
1.7.5 
S (DK): socket-outlets for providing power to other 
equipment shall be in accordance with the Heavy 
Current Regulations, Section 107-2-D1, Standard 
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used 
on Class I equipment 
No socket-outlet. 
 
A (DK): Class II equipment shall not be fitted with 
socket-outlets for providing power to other 
equipment 
No socket-outlet. 
1.7.12 
A (DE): (Gesetz über techische Arbeitsmittel 
(Gerätesicherheitsgesetz) [Law on technical 
labour equipment {Equipment safety law}], of 23
rd
 
October 1992, Article 3, 3
rd
 paragraph, 2
nd
 
sentence, together with the "Allgemeine 
Verwaltungsvorschrift zur Durchführung des 
Zweiten Abschnitts des 
Gerätesicherheitsgesetzes" [General 
administrative regulation on the execution of the 
Second Section of the Equipment safety law], of 
10
th
 January 1996, article 2, 4
th
 paragraph item 2) 
Directions for use with rules to prevent certain 
hazards for (among others) maintenance of the 
technical labour equipment, also for imported 
technical labour equipment shall be written in the 
German language. 
NOTE: Of this requirement, rules for use even 
only by service personnel are not exempted 
German users manual will be 
provided when introducted for 
german market. 
1.7.15 
A (CH): (Ordinance on environmentally hazardous 
substances SR 814.013) Annex 4.10 of 
SR 814.013 applies for batteries 
No batteries. 
 
F (ALL): warning texts for lithium batteries 
Ditto. 
 
Languages .......................................................... :   
 
2.2.4 
S (NO): requirements according to this annex, 
sub-clauses 1.7.2 and 6.1.2.1 apply  
No TNV. 
2.3.2 
S (NO): requirements according to this annex, 
sub-clause 6.1.2.1 apply 
No TNV. 
2.3.3 
S (NO): requirements according to this annex, 
sub-clause 6.1.2.1 apply 
No TNV. 
2.3.4 
S (NO): requirements according to this annex, 
sub-clauses 1.7.2 and 6.1.2.1 apply 
No TNV. 
2.7.1 
C: replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short circuits 
and earth faults in primary circuits, protective 
devices shall be included either as integral parts 
of the equipment or as parts of the building 
installation, subject to the following, a), b), and c): 
a) Except as detailed in b) and c), protective 
devices necessary to comply with the 
requirements of 5.3 shall be included as integral 
Replaced. 
 
 
<12007721 001> 
 
 
Page 46 of 102 
 
IEC 60950 / EN 60950 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
TRF No.: IECEN60950A 
 
TRF originator: SGS FIMKO 
parts of the equipment. 
b) For components in series with the mains input 
to the equipment such as the supply cord, 
appliance coupler, r.f.i.  filter and switch, short 
circuit and earth fault protection may be provided 
by protective devices in the building installation. 
c) It is permitted for pluggable equipment type B 
or permanently connected equipment, to rely on 
dedicated overcurrent and short circuit protection 
in the building installation, provided that the 
means of protection, e.g. fuses or circuit breakers, 
is fully specified in the installation instruction. 
If reliance is placed on protection in the building 
installation, the installation instructions shall  so 
state, except that for pluggable equipment type A 
the building installation shall be regarded as 
providing protection in accordance with the rating 
of the wall socket outlet 
2.7.2 
C: This subclause has been declared 'void' 
Declared. 
2.10.3.1 
S (NO): due to the IT power distribution system 
used (see annex V, figure V.7), the a.c. mains 
supply voltage is considered to be equal to the 
line-to-line voltage, and will remain at 230 V in 
case of a single earth fault 
Considered. 
3.2.1 
S (CH): supply cords of equipment having a rated 
current not exceeding 10 A shall be provided with 
a plug complying with SEV 1011 or IEC 884-1 and 
one of the following dimensions sheets: 
- SEV 6532-2:1991: plug type 15, 3P+N+PE 
250/400 V, 10 A 
- SEV 6533-2:1991: plug type 11, L+N 250 V, 10 A 
- SEV 6534-2:1991: plug type 12, L+N+PE 250 V, 
10 A 
In general, EN 60 309 applies for plugs for 
currents exceeding 10 A. However, a 16 A plug 
and socket-outlet system is being introduced in 
Switzerland, the plugs of which are according to 
the following dimension sheets, published in 
February 1998: - SEV 5932-2:1998: plug type 25, 
3L+N+PE 230/400 V, 
16 A - SEV 5933-2:1998: plug type 21, L+N 250 V, 
16 A 
- SEV 5934-2:1998: plug type 23, L+N+PE 250 V, 
16 A 
No supply cord provided. 
 
S (DK): supply cords of single-phase equipment 
having a rated current not exceeding 10 A shall be 
provided with a plug according to the Heavy 
Current Regulations Section 107-2-D1. 
Class I equipment provided with socket-outlets 
with earth contacts or which are intended to be 
No supply cord provided. 