<12007721 001>
Page 43 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
Separate test report
Certified triple insulation wire
used.
P
<12007721 001>
Page 44 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
SPECIAL NATIONAL CONDITIONS AND NATIONAL DEVIATIONS
S =
S =
Special National Condition,
A =
National Deviation (A-deviation),
C =
CENELEC Common
Modification,
F =
other information
P
C: delete all the "country" notes that appear on the
following pages of the reference document
(IEC 60950:1999): 85, 91, 99, 103, 117, 119, 123,
125, 149, 171, 213, 215, 219, 251, 283, 325, 327,
331, 333 and 407
Class II equipment.
N
1.2.4.1
S (DK): certain types of Class I appliances (see
subclause 3.2.1) may be provided with a plug not
establishing earthing continuity when inserted into
Danish socket-outlets
Class II equipment.
N
1.5.1
A (CH, SE): add the following:
NOTE: Switches containing mercury such as
NOTE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed
No such switch.
N
1.5.8
S (NO): due to the IT power system used (see
annex V, figure V.7), capacitors are required to be
rated for the applicable phase-to phase voltage
(230 V)
Considered, see report IEC
60950.
N
1.7.2
S (NO): class I pluggable equipment type A
intended for connection to other equipment or a
communication network shall, if safety relies on
connection to protective earth, require a marking
stating that the equipment must be connected to
an earthed mains socket outlet
Class II equipment.
N
S (SE): if the separation between the mains and
SELV terminal relies upon connection to the
safety earth, the apparatus shall have a marking
stating that it must be connected to an earthed
mains socket-outlet.
The marking text shall be in Swedish and as
The marking text shall be in Swedish and as
follows: "Apparaten skall anslutas till jordat uttag
när den ansluts till ett nätverk."
Class II equipment.
N
A (DK): supply cords of Class I equipment, which
are delivered without a plug must be provided with
a visible tag with the following text:
"Vigtigt! Lederen med grøn/gul isolation må kun
"Vigtigt! Lederen med grøn/gul isolation må kun
tilsluttes en klemme mærket
(IEC 417, No. 5019 eller IEC 417, No. 5017)."
If essential for the safety of the equipment, the tag
must in addition be provided with a diagram,
which shows the connection of the other
conductors, or be provided with the following text:
"For tilslutning af de øvrige ledere, se
"For tilslutning af de øvrige ledere, se
medfølgende installationsvejledning."
Class II equipment.
N
<12007721 001>
Page 45 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
1.7.5
S (DK): socket-outlets for providing power to other
equipment shall be in accordance with the Heavy
Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used
on Class I equipment
No socket-outlet.
N
A (DK): Class II equipment shall not be fitted with
socket-outlets for providing power to other
equipment
No socket-outlet.
N
1.7.12
A (DE): (Gesetz über techische Arbeitsmittel
(Gerätesicherheitsgesetz) [Law on technical
labour equipment {Equipment safety law}], of 23
rd
October 1992, Article 3, 3
rd
paragraph, 2
nd
sentence, together with the "Allgemeine
Verwaltungsvorschrift zur Durchführung des
Zweiten Abschnitts des
Gerätesicherheitsgesetzes" [General
administrative regulation on the execution of the
Second Section of the Equipment safety law], of
10
th
January 1996, article 2, 4
th
paragraph item 2)
Directions for use with rules to prevent certain
hazards for (among others) maintenance of the
technical labour equipment, also for imported
technical labour equipment shall be written in the
German language.
NOTE: Of this requirement, rules for use even
NOTE: Of this requirement, rules for use even
only by service personnel are not exempted
German users manual will be
provided when introducted for
german market.
N
1.7.15
A (CH): (Ordinance on environmentally hazardous
substances SR 814.013) Annex 4.10 of
SR 814.013 applies for batteries
No batteries.
N
F (ALL): warning texts for lithium batteries
Ditto.
N
Languages .......................................................... :
2.2.4
S (NO): requirements according to this annex,
sub-clauses 1.7.2 and 6.1.2.1 apply
No TNV.
N
2.3.2
S (NO): requirements according to this annex,
sub-clause 6.1.2.1 apply
No TNV.
N
2.3.3
S (NO): requirements according to this annex,
sub-clause 6.1.2.1 apply
No TNV.
N
2.3.4
S (NO): requirements according to this annex,
sub-clauses 1.7.2 and 6.1.2.1 apply
No TNV.
N
2.7.1
C: replace the subclause as follows:
Basic requirements
To protect against excessive current, short circuits
Basic requirements
To protect against excessive current, short circuits
and earth faults in primary circuits, protective
devices shall be included either as integral parts
of the equipment or as parts of the building
installation, subject to the following, a), b), and c):
a) Except as detailed in b) and c), protective
a) Except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as integral
Replaced.
P
<12007721 001>
Page 46 of 102
IEC 60950 / EN 60950
Clause
Requirement
−
Test
Result – Remark
Verdict
TRF No.: IECEN60950A
TRF originator: SGS FIMKO
parts of the equipment.
b) For components in series with the mains input
b) For components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short
circuit and earth fault protection may be provided
by protective devices in the building installation.
c) It is permitted for pluggable equipment type B
c) It is permitted for pluggable equipment type B
or permanently connected equipment, to rely on
dedicated overcurrent and short circuit protection
in the building installation, provided that the
means of protection, e.g. fuses or circuit breakers,
is fully specified in the installation instruction.
If reliance is placed on protection in the building
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for pluggable equipment type A
the building installation shall be regarded as
providing protection in accordance with the rating
of the wall socket outlet
2.7.2
C: This subclause has been declared 'void'
Declared.
N
2.10.3.1
S (NO): due to the IT power distribution system
used (see annex V, figure V.7), the a.c. mains
supply voltage is considered to be equal to the
line-to-line voltage, and will remain at 230 V in
case of a single earth fault
Considered.
P
3.2.1
S (CH): supply cords of equipment having a rated
current not exceeding 10 A shall be provided with
a plug complying with SEV 1011 or IEC 884-1 and
one of the following dimensions sheets:
- SEV 6532-2:1991: plug type 15, 3P+N+PE
- SEV 6532-2:1991: plug type 15, 3P+N+PE
250/400 V, 10 A
- SEV 6533-2:1991: plug type 11, L+N 250 V, 10 A
- SEV 6534-2:1991: plug type 12, L+N+PE 250 V,
- SEV 6533-2:1991: plug type 11, L+N 250 V, 10 A
- SEV 6534-2:1991: plug type 12, L+N+PE 250 V,
10 A
In general, EN 60 309 applies for plugs for
In general, EN 60 309 applies for plugs for
currents exceeding 10 A. However, a 16 A plug
and socket-outlet system is being introduced in
Switzerland, the plugs of which are according to
the following dimension sheets, published in
February 1998: - SEV 5932-2:1998: plug type 25,
3L+N+PE 230/400 V,
16 A - SEV 5933-2:1998: plug type 21, L+N 250 V,
16 A
- SEV 5934-2:1998: plug type 23, L+N+PE 250 V,
- SEV 5934-2:1998: plug type 23, L+N+PE 250 V,
16 A
No supply cord provided.
N
S (DK): supply cords of single-phase equipment
having a rated current not exceeding 10 A shall be
provided with a plug according to the Heavy
Current Regulations Section 107-2-D1.
Class I equipment provided with socket-outlets
Class I equipment provided with socket-outlets
with earth contacts or which are intended to be
No supply cord provided.
N