DOWNLOAD Harman Kardon DVD 27 (serv.man15) Service Manual ↓ Size: 1.43 MB | Pages: 56 in PDF or view online for FREE

Model
DVD 27 (serv.man15)
Pages
56
Size
1.43 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-27-sm15.pdf
Date

Harman Kardon DVD 27 (serv.man15) EMC - CB Certificate ▷ View online

 
 
- Page 24 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals. 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No cover fixing devices other 
than screws 
17.8 
Fixing devices for detachable legs or stands 
provided 
No detachable provided 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Connections complies, 
checked by inspection 
 
 
 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965: 
No CRT in the equipment 
 
Picture tube separately approved to 18.1 ...............
 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 7 kg  ................. :
Weight:  2,6 kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions 
 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
19.2 
100 N force applied vertically downwards 
 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
< 25 kg, < 1M 
 
 
- Page 25 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
19.4 
Edges or corners not hazardous 
There is no hazardous edges 
or corners when the 
apparatus is operating in 
normal position 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
19.6 
Wall or ceiling mountings adequate 
Not intended for wall or ceiling 
mounting 
 
 
 
 
20 
RESISTANCE TO FIRE 
 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 
 
b) Exemption for small components as defined in 
20.1 
PCB is of flammability class  
V-1 and exception is made for 
small componets. 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
Electrical components comply 
with flammability requirements 
in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No wires working at voltages 
> 4kV or leaving an internal 
fire enclosure 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
All PCB is of base material 
with flammability category V-1 
or better. See appended table
 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
No voltage exceeding 400V 
(peak) a.c. or d.c. 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
No such components 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
No such components 
 
 
- Page 26 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
20.2 Fire 
enclosure 
 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
No voltages exceeding 4kV, 
no fire enclosure requirement 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
No internal fire enclosure. 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
No internal fire enclosure. 
 
 
- Page 27 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 
A.10.2.1 
Enclosure provides protection against splashing water
 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No connection to TNV circuits 
 
Complies with IEC 62151 clause 2 
 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard 
 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard
 
 
Complies with IEC 62151 clause 6  
 
 
Complies with IEC 62151 clause 7  
 
 
Complies with IEC 62151 annex A, B and C 
 
 
IEC 62151 clause 4.1.1: 
Add after the first paragraph: 
NOTE- In Finland, Norway and Sweden, class I 
equipment which is intended for connection to the 
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that the 
equipment must be connected to an earthed mains 
socket-outlet. 
The marking text in the applicable countries shall be 
as follow: 
In Finland,  
"Laite on liitettävä suojamaadoituskoskettimilla va 
rustettuunpistorasiaan” 
 
In Norway, 
"Apparatet må tilkoples jordet stikkontakt" 
 
In Sweden, 
"Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
Page of 56
Display

Click on the first or last page to see other DVD 27 (serv.man15) service manuals if exist.