- Page 24 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0,2 A
other than ceramic for connections carrying a
current > 0,2 A
No contact pressure
transmitted through insulating
material.
transmitted through insulating
material.
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminals.
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices other
than screws
than screws
N
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable provided
N
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Connections complies,
checked by inspection
checked by inspection
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No CRT in the equipment
N
Picture tube separately approved to 18.1 ...............
N
18.1
Picture tubes > 16 cm intrinsically protected
N
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N
18.2
Intrinsically protected tubes: tests on 12 samples
N
18.2.1
Samples subject to ageing: 6
N
18.2.2
Samples subject to implosion test: 6
N
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N
18.3
Non-intrinsically protected tubes tested to 18.3
N
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg ................. :
Weight: 2,6 kg
⎯
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
N
19.1
Test on a plane, inclined at 10
o
to the horizontal
N
19.2
100 N force applied vertically downwards
N
19.3
Apparatus mass > 25 kg or height > 1 M or
supplied with cart or stand
supplied with cart or stand
< 25 kg, < 1M
N
- Page 25 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
19.4
Edges or corners not hazardous
There is no hazardous edges
or corners when the
apparatus is operating in
normal position
or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces with an area exceeding 0,1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
maximum dimension > 450 mm, pass the test of
19.5.1
No glass surface
N
19.6
Wall or ceiling mountings adequate
Not intended for wall or ceiling
mounting
mounting
N
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-1 and exception is made for
small componets.
V-1 and exception is made for
small componets.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCB is of base material
with flammability category V-1
or better. See appended table
with flammability category V-1
or better. See appended table
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
No such components
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N
- Page 26 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N
- Page 27 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N
A.10.2.1
Enclosure provides protection against splashing water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connection to TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N