- Page 12 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
No mains switch. 
8.19.2 
Mains switch ON indication 
Display lit-on 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
No mains switch. 
 
 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages >1000 V ac or 
>1500 V dc 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored voltages 
between 60V - 15kV 
 
Energy of discharge not exceeding 350 mJ 
No part or contact of a 
terminal with stored voltages 
exceeding 15kV 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous live 
parts 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No live shafts, handles or 
levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
No ventilation holes in top 
side of the cover. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Does not reach hazardous live 
parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Does not reach hazardous live 
parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set controls 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
Measured discharge voltage a
fter 2 sec.: <1V (peak) 
Discharge resistor provided, R
901 (1M
Ω, 1/2W) 
 
If C is not greater than 0,1 μF no test needed 
> 0,1 uF 
 
 
- Page 13 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger results in 
no hazard. 
 
Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results in 
no hazard. 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... :
Tested with 100N results in  
no damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by hand 
 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
> 4 M
Ω 
10.2 Humidity 
treatment 48 h or 120 h ........................... :
120 h  (40
°C). No impairment 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
 
 
 
11 FAULT 
CONDITIONS 
 
11.1 
No shock hazard under fault condition 
No electric shock hazard under 
fault conditions. 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
No solder soften. 
11.2.1 
Measurement of temperature rises 
See appended table and  
attachment, Table to  
EN/IEC 60065 7
th
 edition 
11.2.2 
Temperature rise of accessible parts 
See appended table and  
attachment, Table to 
EN/IEC 60065 7
th
 edition 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
See appended table and  
attachment, Table to  
EN/IEC 60065 7
th
 edition 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
No area where temperature 
exceeds 100K above limits 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 
 
 
- Page 14 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
No conductors are 
interrupted/peeled/loosened 
during fault conditions 
 
Class I protective earthing maintained 
Class II equipment 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
Temperature rises are within  
the limits.
 
11.2.5 
Temperature rise of windings 
See appended table and  
attachment, Table to  
EN/IEC 60065 7
th
 edition 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
No excessive temperature 
observed/measured on other 
parts 
 
 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
< 7 kg 
12.1.2 Vibration 
test 
Assessed to be satisfactory 
constructed. 
12.1.3 
Impact hammer test 
No damage in the sense of 
this standard 
 
Steel ball test 
No damage in the sense of 
this standard 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Not portable apparatus 
12.1.5 
Thermoplastic enclosures strain relief test 
Tested, 70ºC, 7h 
12.2 
Fixing of knobs, push buttons, keys and levers 
Normal use will not impair the 
protection against electric 
shock. 
12.3 
Remote controls with hazardous live parts 
No remote controllers with 
hazardous live parts. 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers 
12.5 
Antenna coaxial sockets providing isolation 
No antenna socket which 
insolate hazardous live parts from 
accessible parts. 
12.6 
Telescoping or rod antennas construction 
No antenna
 
12.6.1 
Telescoping or rod antennas securement 
 
 
 
- Page 15 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
Creepage distances in accordance with 13.4 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
13.2 
Determination of operating voltage 
Conventional transformer 
used. 
Upper rated supply voltage 
applied in determining the 
operating voltage. 
13.3 Clearances 
2N for internal parts and 30N 
for enclosures are considered 
when determining clearances.
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
Creepage distances greater than table 11 minima 
Not applicable 
13.5 Printed 
boards 
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
No type B coated PWB
 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
Jointed insulation not applied 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
No enclosed, enveloped or 
hermetically sealed parts 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
Approved optocouplers,  
see list of critical components. 