Harman Kardon DVD 27 (serv.man15) EMC - CB Certificate ▷ View online
- Page 16 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14 COMPONENTS
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes,
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
C930, C932 and C933 are Y
capacitors; Certified acc. to
IEC 384-14, 2nd edition.
capacitors; Certified acc. to
IEC 384-14, 2nd edition.
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
C901 and C902 are X
capacitors; Certified acc. to
IEC 384-14, 2nd edition.
capacitors; Certified acc. to
IEC 384-14, 2nd edition.
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
C903 E. cap. Volume
exceeding 1750 mm
exceeding 1750 mm
3
,
but metal cases.
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
C903 E. cap. Volume
exceeding 1750 mm
exceeding 1750 mm
3
,
but metal cases.
N
Shielded by a barrier to V-0 or metal ..................... :
N
14.3
Inductors and windings
See below.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Adequate marking applied.
Mfr. ID and type no.
Mfr. ID and type no.
P
Transformers and inductors separately approved . :
No
N
14.3.2 General
Isolating transformer
P
14.3.3 Constructional
requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
- Page 17 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.3.3.2
Transformers meet the constructional
requirements
requirements
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between primary and secondary
windings according to clause 8.8.
between primary and secondary
windings according to clause 8.8.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the requireme
nt
of reinforced insulation; bobbin t
hickness > 0,4 mm.
nt
of reinforced insulation; bobbin t
hickness > 0,4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II apparatus. No such
transformer used.
transformer used.
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the requireme
nt
of reinforced insulation; bobbin t
hickness > 0,4 mm.
nt
of reinforced insulation; bobbin t
hickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of Class II
construction used.
construction used.
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
No high voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
P
Protective devices used within their ratings
Fuse, F901
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified fuse used.
See appended table, list of criti
cal components.
See appended table, list of criti
cal components.
P
- Page 18 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.5.1.1
a) Thermal cut-outs separately approved
None
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
None
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are certified according
to IEC60127
to IEC60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... :
Correct marking applied close
to the fuse;
”F901, 250V, T2AL”
to the fuse;
”F901, 250V, T2AL”
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that
fuse-links can be connected in
parallel
fuse-links can be connected in
parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N
PTC-S devices (15 W) category V-1 or better
None
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No such components
N
14.6 Switches
No mains switch
N
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
V-0 compliance with annex G, G.1.1
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3, and
V-0 compliance with annex G, G.1.1
N
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N
- Page 19 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
additional tests to IEC 61058-1
N
Socket outlet current marking correct
N
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
No voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
Only sec. DC low voltage
motors for DVD player.
No special test is necessary.
motors for DVD player.
No special test is necessary.
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10 Batteries
No batteries
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within manufacture
rs limits
rs limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
Click on the first or last page to see other DVD 27 (serv.man15) service manuals if exist.