DOWNLOAD Harman Kardon DVD 27 (serv.man15) Service Manual ↓ Size: 1.43 MB | Pages: 56 in PDF or view online for FREE

Model
DVD 27 (serv.man15)
Pages
56
Size
1.43 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dvd-27-sm15.pdf
Date

Harman Kardon DVD 27 (serv.man15) EMC - CB Certificate ▷ View online

 
 
- Page 16 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14 COMPONENTS 
 
14.1 Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Not used 
 
b) Resistors separately approved .......................... :
 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes, 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
C930, C932 and C933 are Y 
capacitors;  Certified acc. to 
IEC 384-14, 2nd edition. 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
C901 and C902 are X 
capacitors;  Certified acc. to 
IEC 384-14, 2nd edition. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... :
No such capacitors 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
C903 E. cap. Volume 
exceeding 1750 mm
3
but metal cases. 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
C903 E. cap. Volume 
exceeding 1750 mm
3
but metal cases. 
 
Shielded by a barrier to V-0 or metal  ..................... :
 
14.3 
Inductors and windings 
See below. 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Transformers evaluated  
according to 14.3.3, 14.3.4  
and 14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
Adequate marking applied. 
Mfr. ID and type no. 
 
Transformers and inductors separately approved . :
No 
14.3.2 General 
Isolating transformer 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
See attachment, Table to  
EN/IEC 60065 7
th
 edition 
 
 
- Page 17 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.3.3.2 
Transformers meet the constructional 
requirements 
See attachment, Table to  
EN/IEC 60065 7
th
 edition 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation  
between primary and secondary  
windings according to clause 8.8. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the requireme
nt 
of reinforced insulation; bobbin t
hickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II apparatus. No such 
transformer used. 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the requireme
nt 
of reinforced insulation; bobbin t
hickness > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II 
construction used. 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
14.4 
High voltage components 
No high voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Fuse, F901 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Certified fuse used. 
See appended table, list of criti
cal components. 
 
 
- Page 18 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.5.1.1 
a) Thermal cut-outs separately approved 
None 
 
b) Thermal cut-outs tested as part of the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
None 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are certified according 
to IEC60127 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :
Correct marking applied close 
to the fuse; 
”F901, 250V, T2AL”  
14.5.2.3 
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that 
fuse-links can be connected in 
parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
No replacement of fuse  
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
None 
 
PTC-S devices (15 W) category V-1 or better 
None 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
No such components 
14.6 Switches 
No mains switch 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3, and 
V-0 compliance with annex G, G.1.1 
 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
 
 
- Page 19 of 36 - 
 
 
www.nemko.com
 
Report No.  65335 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
 
 
Socket outlet current marking correct 
 
14.7 Safety 
interlocks 
 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 
14.9 Motors 
Only sec. DC low voltage  
motors for DVD player. 
No special test is necessary.  
14.9.1 
Endurance test on motors 
 
 
Motor start test 
 
 
Dielectric strength test 
 
14.9.2 
Not adversely affected by oil or grease etc. 
 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
14.10 Batteries 
No batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
14.10.3 
Recharging currents and times within manufacture
rs limits 
 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
Page of 56