Harman Kardon DVD 27 (serv.man15) EMC - CB Certificate ▷ View online
- Page 8 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No CRT
N
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... :
Measured wavelength
(CD/DVD): 791nm / 658nm
(CD/DVD): 791nm / 658nm
Measured power (CD/DVD): 4
3,0uW / 54,4uW
3,0uW / 54,4uW
AEL of Class 1 (CD/DVD): 59
3uW / 390uW
3uW / 390uW
Within AEL of Class 1 /
Class 1 Laser Product.
Class 1 Laser Product.
(Measured by JQA, Report No
. 384-30310-1)
. 384-30310-1)
P
Emission limits under fault conditions .................... :
Measured wavelength (CD/DV
D): 791nm / 658nm
D): 791nm / 658nm
Measured power (CD/DVD): 2
92uW / 311uW
92uW / 311uW
AEL of Class 1 (CD/DVD): 59
3uW / 390uW
3uW / 390uW
Within AEL of Class 1 / Class
1 Laser Product (inside)
1 Laser Product (inside)
(Measured by JQA, Report No
. 384-30310-1)
. 384-30310-1)
P
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
(see appended table)
P
7.1.4
Temperature rise of windings
(see appended table)
P
- Page 9 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
< 0,2A
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible
not possible
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by hand
N
8.5
Class I equipment
Class II equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II apparatus.
P
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The apparatus has isolating
transformer.
transformer.
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
C930, C932, and C933
capacitors; inside the
enclosure
capacitors; inside the
enclosure
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components
N
- Page 10 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35V to 71V (peak)
a.c. or 60V to 120V d.c.
a.c. or 60V to 120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c. or
60-120V d.c.
60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer according to
14.3.2. (Class II)
14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
a. Transformer bobbin thick.:
>0,4mm, ref. 14.3.
b. Sheet of insulation in
bottom side of the SMPS
between primary and metal
chassis.
Tested at 3KV, 1 min. acc.
to clause 10.3 - OK
c. Distance through insulation
in
>0,4mm, ref. 14.3.
b. Sheet of insulation in
bottom side of the SMPS
between primary and metal
chassis.
Tested at 3KV, 1 min. acc.
to clause 10.3 - OK
c. Distance through insulation
in
optocoupler
≥0.4 mm.
ref.
14.11.
P
Thin sheet insulation
P
Basic or supplementary insulation, at least two lay
ers, each meeting 10.3
ers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Transformer with thin sheet
insulation, ref. 14.3.
insulation, ref. 14.3.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
DVD 27/230:
External supply cord only,
double insulated.
DVD 47/230:
Internal wires for appliance
inlet, double insulated.
External supply cord only,
double insulated.
DVD 47/230:
Internal wires for appliance
inlet, double insulated.
P
- Page 11 of 36 -
www.nemko.com
Report No. 65335
TRF No: IEC/EN 60065F
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Double insulated, tested
according to 8.9. and 10.3.
according to 8.9. and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
DVD 27/230:
Primary wires in external cord
s connected with multi-
contact-housing.
DVD 47/230:
Conductors of internal primary
wires for appliance inlet hook-
in befor soldered, other end
of inlet wires are connected wi
th multi-contact-housing.
Primary wires in external cord
s connected with multi-
contact-housing.
DVD 47/230:
Conductors of internal primary
wires for appliance inlet hook-
in befor soldered, other end
of inlet wires are connected wi
th multi-contact-housing.
P
Vibration
test carried out ........................................ :
See 12.1.2
N
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlets
N
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
NO TIW used
N
8.18
Endurance test as required by 8.17
N
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
DVD 27/230:
Mains plug is used as
disconnect device
DVD 47/230:
Appliance coupler is used as
disconnect device
Mains plug is used as
disconnect device
DVD 47/230:
Appliance coupler is used as
disconnect device
P