Harman Kardon DVD 27 (serv.man12) EMC - CB Certificate ▷ View online
- IEC 60065 6
th
edition (1998)
- Page 2 of 36 -
Order No.
48750
Additional test according to:
Common Modifications, Special National Conditions and
National Deviations
National Deviations
CENELEC EN 60065:1998. Common Modifications,
Special National Conditions and National Deviations.
(See Appendix CENELEC EN 60065:1998)
Special National Conditions and National Deviations.
(See Appendix CENELEC EN 60065:1998)
Other requirements
General remarks:
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Possible test case verdicts:
P = Pass, F = Fail, N = Not applicable. Placed in the column to the right (Verdict)
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to a table appended to the report.
The test results presented in this report relate only to the object tested.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
Possible test case verdicts:
P = Pass, F = Fail, N = Not applicable. Placed in the column to the right (Verdict)
ADDITIONAL INFORMATION
DESCRIPTION OF EQUIPMENT UNDER TEST:
9
DVD Player, RCA terminals Optical terminal, S-Video terminal and SCART terminal provided
(see also photos).
(see also photos).
NAME AND ADDRESS OF OTHER PRODUCTION-SITES (FACTORIES):
9
DongGuan LiaoBu Anam Electronics.
Xin Cheng Management Area, LiaoBu Town, DongGuan City, GuangDong Province, China.
Xin Cheng Management Area, LiaoBu Town, DongGuan City, GuangDong Province, China.
INFORMATION ABOUT OTHER STANDARDS / DOCUMENTS CONSIDERED:
9
IEC/EN 60825-1
TESTED ACCORDING TO NATIONAL REQUIREMENTS FOR THE FOLLOWING
COUNTRIES:
COUNTRIES:
9
CENELEC Countries and Singapore
LIST OF APPENDIXES / ENCLOSURES TO THE TEST REPORT:
9
CENELEC EN 60065:1998
National deviations for Singapore
Photos
- IEC 60065 6
th
edition (1998)
- Page 3 of 36 -
Order No.
48750
SUMMARY OF TESTING:
P
The apparatus is complies with the requirements in IEC 60065:1998 and EN 60065:1998
Clause Information/Remarks
Comments
- IEC 60065 6
th
edition (1998)
- Page 4 of 36 -
Order No.
48750
TEST REPORT INFORMATION
It should be taken into account that this test report does not replace the text in the test specification.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the
actual specification mentioned.
IEC 60065, 6th edition:1998
The meaning of certain marks and abbreviations (Voltages and currents are r.m.s. values unless otherwise
specified)
specified)
OK
= no remarks
pr
= primary
?
= unclear, borderline case
sec
= secondary
∆t
= temperature rise
pr-sec
= primary-secondary
tpr
= thermal paper
pr-ss
= primary-static screen
h, m, s = hour, minute, second
pr-ic
= primary-iron core
U, I, P = voltage, current, power
pr-tra
= primary-transformer encl.
û,î
= peak value
F
= fuse
n
= rated
PWB
= printed wiring board
9
= issue checked/inspected
LSL
= loudspeaker load
- IEC 60065 6
th
edition (1998)
- Page 5 of 36 -
Order No.
48750
Standardized approval marks
1
SCOPE
According to standards mentioned.
9
2
DEFINITIONS
According to standards mentioned.
9
3
GENERAL REQUIREMENTS
According to standards mentioned.
9
Safety class of the apparatus
Class II
9
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to standards mentioned.
9
4.1.4 -
4.2.12.
4.2.12.
Normal operating
conditions/position/adjustments
conditions/position/adjustments
With all users controls set to obtain maximum power
from the mains. Positioned in a test box.
from the mains. Positioned in a test box.
9
5
MARKING AND INSTRUCTIONS
P
Copy of the markings :
Comprehensible and easily
discernible
discernible
On front and rear of the enclosure
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
Adequate marking applied
P
Class II symbol
P
Rated supply voltage and symbol
230V with AC-symbol (
~
)
P
Rated mains frequency
50Hz
P
Click on the first or last page to see other DVD 27 (serv.man12) service manuals if exist.