Harman Kardon DVD 27 (serv.man12) EMC - CB Certificate ▷ View online
- IEC 60065 6
th
edition (1998)
- Page 6 of 36 -
Order No.
48750
Rated current or power
consumption
consumption
12W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
No socket outlet for providing power to other apparatus
N
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening.
connection with CAUTION of opening.
P
5.4
Instructions for use
English. Also should be in a language acceptable for the
countries where the apparatus is to be sold.
countries where the apparatus is to be sold.
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Described in the instruction manual
P
Hazardous live terminals,
instructions for wiring
instructions for wiring
No hazardous live terminals
P
Instructions for replacing lithium
battery
battery
No lithium battery
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No MOMS
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF
from the mains, info required
connected equipment
If not completely switched OFF
from the mains, info required
The apparatus is not for permanent connection
N
6
HAZARDOUS RADIATION
Laser radiation
P
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
Class 1 Laser Product.
Laser radiation classification according to IEC 60825-1
based on measurements by JQA, Ref. No. 384-30310-1
Laser radiation classification according to IEC 60825-1
based on measurements by JQA, Ref. No. 384-30310-1
P
6.2.1
Opening of any cover by hand
No opening of covers by hands
P
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
Radiation power: 54,4
µW for DVD
Radiation power: 43,0
µW for CD
Within AEL of Class 1 Laser Product
See JQA, test report (Ref. No. 384-30310-1)
See JQA, test report (Ref. No. 384-30310-1)
P
Labelling
Class 1 Laser Product
P
- IEC 60065 6
th
edition (1998)
- Page 7 of 36 -
Order No.
48750
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
Radiation power: 311
µW for DVD (inside)
Radiation power: 292
µW for CD (inside)
Within AEL of Class 1
See JQA, test report (Ref. No 384-30310-1)
See JQA, test report (Ref. No 384-30310-1)
P
Warning label requirement
No requirement
N
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
In OFF/Stand-by position, the power consumption is
less than 1W.
less than 1W.
P
Surge current needed in clause
14.6 when testing mains switches
or functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
14.6 when testing mains switches
or functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
No mains switch
N
- IEC 60065 6
th
edition (1998)
- Page 8 of 36 -
Order No.
48750
7.1
Standby mode,
U
=
207,0
V, I
=
0,02
A, P
=
0,8
W,
Pout =
W
U
=
230,0
V, I
=
0,02
A, P
=
0,9
W,
Pout =
W
U
=
254,4
V, I
=
0,02
A, P
=
0,9
W,
Pout =
W
Measured at DVD play mode,
U
=
207,0
V, I
=
0,12
A, P
=
11,4
W,
Pout =
W
U
=
230,0
V, I
=
0,11
A, P
=
11,4
W,
Pout =
W
U
=
254,4
V, I
=
0,11
A, P
=
11,4
W,
Pout =
W
Operating conditions:
DVD player operating mode.
U
=
207,0
V, I
=
0,12
A, P
=
11,4
W,
Pout =
W
U
=
254,4
V, I
=
0,11
A, P
=
11,4
W,
Pout =
W
Loudspeaker system(s)
No loudspeaker system(s)
Marking of loudspeaker terminals
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible
parts
parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as
a support or as a mechanical
barrier
a support or as a mechanical
barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
- IEC 60065 6
th
edition (1998)
- Page 9 of 36 -
Order No.
48750
HEATING
∆t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
R1
P
t1 =
24,5 °C
24,5 °C
t2 =
23,5 °C
22,2 °C
Test voltage
207 V
254,4 V
Winding
R1/
Ω R2/Ω
∆t measured
∆t allowed *) Insulation
class
Transformer, T901 winding
- - -
70 Class
A
(See table below)
Other measured parts
∆t measured
at 207,0 V
at 207,0 V
∆t measured
at 254,4 V
at 254,4 V
∆t allowed *)
DVD Spindle motor case
10,0
9,9
-
Diode, D904 body
11,0
10,9
-
E. Capacitor, C903 body
9,6
9,7
-
Q801 body
18,7
20,0
-
Line filter, LF91 coil
9,0
8,7
70
PWB near D904
10,8
10,7
85
PWB near Q801
18,4
19,9
85
Transformer, T901 coil
19,5
19,9
70
Transformer, T901 core
19,0
19,2
70
PWB near D902
26,5
27,0
85
Power cord bushing
6,2
6,1
60
Top enclosure above SMPS power
5,5
5,2
40
Comments
No other parts were observed to create any hazard due to temperature rise.
P
*) Temperature rise limits for Singapore is 10K less. Comply
P
**) Tested in a test box under blocked opening condition of the apparatus.
P
Click on the first or last page to see other DVD 27 (serv.man12) service manuals if exist.