Harman Kardon DVD 27 (serv.man12) EMC - CB Certificate ▷ View online
- IEC 60065 6
th
edition (1998)
- Page 22 of 36 -
Order No.
48750
14.6.7 Endurance
test
N
14.6.8
Temperature rise in mains switch
N
14.6.9
Dielectric strength test
N
14.6.10
Surge current for mains switches
also controlling mains socket-outlets
also controlling mains socket-outlets
N
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to
be changed accidentally
be changed accidentally
No voltage selector
N
14.9 Motors
N
14.9.1
Endurance test on motors
Only secondary DC low voltage motors for DVD player.
No special testing is considered necessary for these
motors.
No special testing is considered necessary for these
motors.
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of
accumulation of flammable gases
accumulation of flammable gases
No battery
N
14.10.2
No possibility of recharging non-
rechargeable batteries
rechargeable batteries
N
14.10.3
Recharging currents and times
within manufacturers limits
within manufacturers limits
N
Lithium batteries discharge and
reverse currents within the
manufacturers limits
reverse currents within the
manufacturers limits
N
14.11 Optocouplers
P
Optocouplers comply with Cl. 8
Insulation thickness: > 0,4 mm
P
Internal and external dimensions to
13.1.1
13.1.1
Internal / external creepage and clearance distance
are >4mm / > 8 mm.
are >4mm / > 8 mm.
P
- IEC 60065 6
th
edition (1998)
- Page 23 of 36 -
Order No.
48750
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer
Type
Standard Certified
Remarks
sheet
by
(colour
etc.)
Mains plug
Kenic Electric Mfg
KE-21
IEC60884-1
VDE
2.5A 250V~, black
Mains sockets and interconnection
couplers
couplers
No socket outlets
N
Overload protection for
socket-outlets
socket-outlets
N
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Standard connectors provided for S-Video, SCART,
Optical and RCA terminals.
Optical and RCA terminals.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
15.2
Provision for protective earthing
Class II apparatus
N
Accessible conductive parts of
Class I equipment reliably
connected to earth terminal, within
equipment
Class I equipment reliably
connected to earth terminal, within
equipment
N
Switches or fuses in protective
earth circuits
earth circuits
N
Class I supply equipment with non-
hazardous live output voltage:
output circuit not connected to earth
hazardous live output voltage:
output circuit not connected to earth
N
Protective earth conductors correctly
coloured
coloured
N
Permanently connected apparatus
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
N
Protective earth connection of a
part removable by hand.
part removable by hand.
N
- IEC 60065 6
th
edition (1998)
- Page 24 of 36 -
Order No.
48750
Protective earth terminal resistant to
corrosion
corrosion
N
Earth resistance (
Ω) test: ≤ 0,1 Ω at
25 A
N
15.3
Terminals for external flexible cords
and for permanent connection to the
mains supply
and for permanent connection to the
mains supply
P
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
Apparatus is not for permanent connection.
N
15.3.2
Reliable connection of non-
detachable cords:
detachable cords:
P
Connection of the non-detachable
cord
cord
Connected with a two-pole connector.
P
Soldered to conductors of a printed
circuit board
circuit board
No
P
Adequate clearances and creepage
distances between connections
should a wire break away
distances between connections
should a wire break away
Wires are clamped two times to the contact terminal and
provided with a two-pole connector
provided with a two-pole connector
P
Wire secured by additional means to
the conductor
the conductor
Adequately anchored. Tested with 5 N.
P
15.3.3
Screws and nuts clamping
conductors have adequate threads:
ISO 261, ISO 262 or similar
conductors have adequate threads:
ISO 261, ISO 262 or similar
No screws and nuts clamping
N
15.3.4
Soldered conductors wrapped
around terminal prior to soldering or
held in place by additional means
around terminal prior to soldering or
held in place by additional means
No soldered conductors
N
Clamping of conductor and
insulation if not soldered or held by
screws
insulation if not soldered or held by
screws
Clamped insulators and conductors
P
15.3.5
Terminals allow connection of
appropriate cross-sectional area of
conductors, for the rated current of
the equipment
appropriate cross-sectional area of
conductors, for the rated current of
the equipment
Terminals have adequate connection capacity.
P
15.3.6
Terminals to 15.3.3 have sizes
required by Table 8
required by Table 8
N
15.3.7
Terminals clamp conductors
between metal surfaces
between metal surfaces
Terminals have adequate pressure without damage the
conductor.
conductor.
P
Terminals designed to avoid
conductor slipping out when
tightened or loosened
conductor slipping out when
tightened or loosened
Adequate construction
P
Terminals adequately fixed to avoid
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
Terminals adequately fixed and clearances and
creepage are not reduced blow required values.
No stress on internal wiring.
creepage are not reduced blow required values.
No stress on internal wiring.
P
- IEC 60065 6
th
edition (1998)
- Page 25 of 36 -
Order No.
48750
15.3.8
Terminals carrying a current more
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
The current is less than 0,2A
N
15.3.9
Termination of non-detachable
cords: wires terminated near to each
other
cords: wires terminated near to each
other
The termination of the contacts are in adequate
proximity to each other.
proximity to each other.
P
Terminals located and shielded: test
with 8 mm strand
with 8 mm strand
Clamped contacts within connector
N
15.4
Devices forming a part of the mains
plug
plug
N
15.4.1
No undue strain on mains socket-
outlets
outlets
The apparatus is not a device forming a part of the
mains plug.
mains plug.
N
15.4.2
Device complies with standard for
dimensions of mains plugs
dimensions of mains plugs
N
15.4.3
Device has adequate mechanical
strength (tests a,b,c)
strength (tests a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type,
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
Sheathed PVC cord complying with IEC 60227
P
Mains cord
Manufacturer
Marking
Cross-
Certified by
(type)
sectional
area
(mm2)
H03VVH2-F
Kenic Electric Mfg
227 IEC52, KELF-75
0.75 mm
2
x 2
VDE
Non-detachable cords for Class I
have green/yellow core for
protective earth
have green/yellow core for
protective earth
Class II apparatus
N
16.2
Mains cords conductors have
adequate cross-sectional area for
rated current consumption of the
equipment
adequate cross-sectional area for
rated current consumption of the
equipment
The cord is 0,75mm², within the current rating
P
16.3
a) Flexible cords not complying with
16.1, used for interconnections
between separate units of
equipment used in combination and
carrying hazardous live voltages,
have adequate dielectric strength
16.1, used for interconnections
between separate units of
equipment used in combination and
carrying hazardous live voltages,
have adequate dielectric strength
No interconnecting cables comprising hazardous live
conductors.
conductors.
N