Harman Kardon DVD 27 (serv.man12) EMC - CB Certificate ▷ View online

 
-   IEC 60065   6
th
 edition (1998)
 
- Page 10 of 36 - 
 
 
   
 
Order No. 
 48750
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°C  
< 0,2 A 
Tested parts 
Temperature 
under normal 
operating con- 
ditions (°C) 
Temperature 
under fault 
conditions  
     (°C) 
Softening 
Temperature 
       (°C) 
 
 
 
 
 
 
 
 
 
8 CONSTRUCTIONAL 
REQUIREMENTS WITH REGARD 
TO THE PROTECTION AGAINST 
ELECTRIC SHOCK  
 
8.1 
Conductive parts covered by 
lacquer, paper, untreated textile 
oxide films and beads etc. 
considered to be bare  
Considered 
8.2 
Shock hazard when changing 
voltage setting device, fuse-links or 
handling drawers etc.  
Operation “By hand” not possible 
8.3 
Insulation of hazardous live parts not 
provided by hygroscopic material  
No hygroscopic materials 
8.4 
Risk of electric shock from 
accessible parts, including when 
covers are removed by hand. 
No cover removable by hand. 
8.5 
Class I equipment 
 
Class II equipment 
 
Basic insulation between hazardous 
live parts and earthed accessible 
parts  
 
 
Resistors bridging basic insulation 
complying with 14.1 a)  
 
 
Capacitors bridging basic insulation 
complying with 14.2.1 a)  
 
 
Basic insulation bridged by 
components complying with 14.3.4.3 
 
 
Protective earth contact 
 
8.6 
Class II equipment and Class II  
constructions within Class I  
equipment 
 
 
 
-   IEC 60065   6
th
 edition (1998)
 
- Page 11 of 36 - 
 
 
   
 
Order No. 
 48750
 
 
 
 
 
Reinforced or double insulation 
between hazardous live parts and 
accessible parts  
Reinforced insulation complies with requirements 
specified in clause 10 and 13. 
 
Components bridging reinforced or 
double insulation complying with 
14.1 a) or 14.3  
The apparatus has an isolating transformer. 
 
Basic and supplementary insulation 
each being bridged by a capacitor 
complying with 14.2.1 a)  
No such capacitors
 
 
Reinforced or double insulation 
being bridged by 2 capacitors in 
series complying with 14.2.1 a)  
No such capacitors 
 
Reinforced or double insulation 
being bridged by a single capacitor 
complying with 14.2.1 b)  
C930, C932, and C933 capacitors;  
inside the enclosure 
8.7 
Basic insulation between parts at 
35 V to 71 V (peak) a.c. or 60 V to 
120 V d.c. and accessible parts  
No parts at 35-71V a.c. or 60-120V d.c. 
 
Reinforced or double insulation 
between circuits operating at 
voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 
120 V d.c. and hazardous live parts 
at higher voltage  
No parts at 35-71V a.c. or 60-120V d.c. 
 
Separation by Class II isolating 
transformer  
Isolating transformer according to 14.3.2. (Class II) 
 
Separation by Class I transformer  
 
 
Separation by earthed conductive 
part  
 
8.8 
Basic or supplementary insulation 
≥ 0,4 mm (mm) 
 
 
Reinforced insulation 
≥ 0,4 mm 
(mm) 
a)  Transformer bobbin thickness: > 0,4mm, ref. 14.3.  
 
b)  Sheet of insulation, bottom and top side of the SMPS
 
between metal chassis/cover and pri. components..
 
Tested at 3000V, 1 min. acc. to clause 10.3 - OK. 
 
Thin sheet insulation used inside  
the enclosure
 
Insulation in transformer 
 
Basic or supplementary insulation, 
at least two layers, each meeting 
10.3  
 
 
Basic or supplementary insulation, 
three layers any two of which meet 
10.3  
 
 
-   IEC 60065   6
th
 edition (1998)
 
- Page 12 of 36 - 
 
 
   
 
Order No. 
 48750
 
 
 
 
 
Reinforced insulation, two layers 
each of which meet 10.3  
 
 
Reinforced insulation, three layers 
any two which meet 10.3  
Transformer with thin sheet insulation, ref. 14.3. 
8.9 Primary 
wiring: 
Adequate insulation between 
internal hazardous live conductors 
and accessible parts  
Supply cord only, double insulated. 
 
Secondary wiring : 
Adequate insulation between 
internal hazardous live parts and 
conductors connected to accessible 
parts  
Single insulated but safely anchored 
8.10 
Class II apparatus : 
Double insulation between 
conductors connected to the mains 
and accessible parts  
Double insulated, tested according to 8.9. and 10.3. 
 
Class II apparatus : 
Double insulation between 
conductors connected to accessible 
parts and the mains  
 
8.11 
Detaching of wires 
 
 
 
No undue reduction of creepage or 
clearance distances if wires become 
detached  
Primary wires in external cords connected with multi-
contact-housing. 
 
Vibration test carried out    
Vibration test considered not necessary 
8.12 
Adequate cross-sectional area of 
internal wiring to mains socket-
outlets  
No mains socket outlets 
8.13 
Adequate fastening of windows, 
lenses, lamp covers etc. (push or 
pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push 
or pull test 50 N, for 10 s)  
Covers adequately fastened with screws. 
8.15 
No risk of damage to the insulation 
of internal wiring due to hot parts or 
sharp edges  
Wires safely anchored away from parts with high 
temperature. 
8.16 
Apparatus designed to be supplied 
by special supply apparatus only.  
 
 
-   IEC 60065   6
th
 edition (1998)
 
- Page 13 of 36 - 
 
 
   
 
Order No. 
 48750
 
 
 
 
ELECTRIC SHOCK HAZARD 
UNDER NORMAL OPERATING 
CONDITIONS  
 
9.1.1 
Touch current expressed as 
voltages U1 and U2 in Annex D  
 
Location Measured 
U1 
V (peak) 
Measured U1
V (DC) 
Measured U2 
V (peak) 
Limits : 
U1 Max 35V (peak)
U1 Max 1.0V (DC) 
U2 Max 0.35V 
(peak) 
Mains pole 1 – Video RCA terminal 
0,27 V (peak) 
0,25 V (peak) 
Pass 
Mains pole 2 – Video RCA terminal 
0,29 V (peak) 
0,25 V (peak) 
Pass 
 
 
 
 
 
 
 
 
 
 
 
Discharge not exceeding 45 
µC  
No part or contact of a terminal with stored voltages 
between 60V - 15kV 
 
Energy of discharge not exceeding 
350 mJ 0 
No part or contact of a terminal with stored voltages 
exceeding 15kV 
 
Test with test finger according to test 
probe B of IEC 61 032 (20N) 
No access to hazardous live parts 
 
For class II constructions, test with 
test probe 13 of IEC 61 032 (3N) 
No access to hazardous live parts 
 
Clearances to circuits exceeding 
1000V a.c. or 1500V d.c.  
No voltages exceeding 1000V AC or 1500V DC. 
9.1.2 
No hazardous live shafts of knobs, 
handlers or levers  
No live shafts, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin  
No ventilation holes in top side of the cover. 
9.1.4 
Terminal devices tested with 
1 mm x 20 mm test pin (10 N); test 
probe 16 of IEC 61 032  
Does not reach hazardous live parts 
 
Terminal devices tested with 
1 mm x 100 mm straight wire (1 N); 
test probe D of IEC 61 032  
Does not reach hazardous live parts 
9.1.5 
Pre-set controls tested with 
2.5 mm x 100 mm test pin (10 N); 
test probe C of IEC 61 032  
No preset controls 
9.1.6 
No shock hazard due to stored 
charge on withdrawal of the mains 
plug; voltage (V) after 2 s   
Measured discharge voltage after 2 sec.: < 1V (peak) 
Discharge resistor provided, R901 (1M
Ω, 1/2W) 
 
If C is not greater than 0,1 
µF no test 
needed  
 
Page of 50