DOWNLOAD Harman Kardon AVR 8500 (serv.man2) Service Manual ↓ Size: 2.25 MB | Pages: 55 in PDF or view online for FREE

Model
AVR 8500 (serv.man2)
Pages
55
Size
2.25 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-8500-sm2.pdf
Date

Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate ▷ View online

 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 1 of 3 - 
 
 
   
 
Order No. 
200211174
 
 
 
APPENDIX   
CENELEC EN 60065:1998 
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL 
DEVIATIONS AND OTHER INFORMATION     
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
 DE 
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden. 
P = Pass, F = Fail, = Not applicable.   
1.1.1 C 
Replace text in Note 1 by : This 
standard can be used as a guide for 
the testing of battery operated 
apparatus.   
 
2.6.1 S 
(DK)  Class I apparatus provided with 
a plug not establishing earthing 
continuity when inserted in Danish 
socket-outlets, see 15.1.1. 
 
Class II apparatus 
3.1 C 
Delete the note. Add the following 
indent : exposure to excessive sound 
pressures from headphones or 
earphones.   
 
 
D 
(DE) Marking in case of intrinsically 
ionizing radiation, cathode-ray tubes 
 
D 
(IT) Marking and instruction 
requirements   
- power consumption (W) for TV 
receivers   
 
6.1 D 
(DE) Limits for ionizing radiation, TV 
receivers (max. 1
µ
Sv/h) 
 
15.1.1 C 
Delete notes 1 and 2. 
Add to note 4: Attention is drawn to 
the fact that a standard is under 
preparation (presently prEN 50074) for 
socket-outlets which allow connection 
of Class II appliances only.   
 
15.1.1 S 
(DK) Mains plug according to Heavy 
Current Regulations, Section 107-2-
D1 
(DK) Mains socket outlets Cl.I 
(DK) Mains socket outlets Cl.II 
The power cord is not provided with the equipment.   
Ref. Summary of Testing. 
15.1.1 S 
(IE) Mains plug, flexible cord, 
according to statutory Instrument 525: 
1997 
The power cord is not provided with the equipment.   
Ref. Summary of Testing. 
15.1.1 S 
(NO) Mains socket outlets CI.II 
 
15.1.1 S 
(GB) Mains plug, flexible cord, 
according to statutory Instrument 
1768: 1994 
The power cord is not provided with the equipment.   
Ref. Summary of Testing. 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 2 of 3 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
15.2 C 
Delete note 2
 
 
 
16.1 C 
Delete note 1
 
 
 
16.2 C 
Delete the note 
 
 
 
20 C 
Delete note 2
 
 
 
 
APPENDIX 
ANNEX B (normative) 
 
 
Annex B C 
Delete note 2 
 
 
B.5.4.1  S 
(NO) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
Applicable text is: 
"Apparatet må kun tilkoples jordet 
stikkontakt" or   
"Jordet stikkontakt skal benyttes når 
apparatet tilkoples datanett" 
Swedish text can also be accepted. 
 
B.5.4.1  S 
(SE) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag när den ansluts till ett nätverk"   
 
B.5.4.1 e) C 
Delete notes 1 and 2 
 
 
B.8.1 C 
Delete notes 1, 2 and 3 
 
 
B.8.1 S 
(DK) Method b) is permitted only for 
PERMANENTLY CONNECTED 
APPARATUS 
 
B.8.1 S 
(NO) Method b) is not permitted 
 
B.8.2 C 
Delete the note 
 
 
B.14.12 C 
Delete notes 1 and 2 
 
 
B.14.12 S 
(DK) The following note is added: 
NOTE in Denmark the use of surge 
suppressors between the 
TELECOMMUNICATION NETWORK 
and conductive ACCESSIBLE parts or 
TERMINALS which are considered to 
be ACCESSIBLE, is allowed only for 
PERMANENTLY CONNECTED 
APPARATUS. 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 3 of 3 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
B.14.12 S 
(NO) The following note is added: 
NOTE in Norway, for Class I 
apparatus intended to be connected 
to the MAINS by means of a plug, 
surge suppressors may only be 
connected between TNV circuits and 
ACCESSIBLE parts if the apparatus 
has a marking stating that it must be 
connected to an earthed MAINS 
socket outlet. 
 
B.14.12 S 
(SE) The following note is added: 
NOTE in Sweden, for Class I 
apparatus intended to be connected 
to the MAINS by means of a plug, 
surge suppressors may only be 
connected between TNV circuits and 
ACCESSIBLE parts if the apparatus 
has a marking stating that it must be 
connected to an earthed MAINS 
socket outlet. 
 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag." 
 
APPENDIX 
ANNEX G (normative) 
 
 
 
Annex G C 
Delete the note 
 
 
APPENDIX 
ANNEX P (informative) 
 
 
 
Annex P C 
Add the following notes for the 
standards indicated : 
IEC 60130 : 
NOTE: IEC 60130-9:1989 + A1:1993 
are harmonized as EN 60130-9 (not 
modified). 
IEC 60169 : 
NOTE: Parts 23, 24 and 25 are 
harmonized as Ens (not modified). 
IEC 60173 :   
NOTE: Harmonized as HD 27 
S1:1983 (not modified). 
IEC 60260 :   
NOTE: Harmonized as HD 98 
S1:1977 (not modified). 
IEC 60335-2-56 : 
NOTE: Harmonized as EN 60335-2-
56: 1997 (not modified). 
IEC 61040 : 
NOTE: Harmonized as EN 61040: 
1992 (not modified). 
IEC 60695 : 
NOTE: Harmonized as EN 60695 
series (not modified). 
 
 
 
 
- Page 1 of 4 - 
 
 
PHOTOS 
 
 
 
Order No.
 200211174
 
 
 
 
 
 
 
 
Page of 55
Display

Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.