Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 44 -
Order No.
200211174
FAULT CONDITION TESTS
P
Ambient temperature
24,8 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D452
S-c
254,4
~ - +
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
D452
S-c
207
~ - +
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
C457
S-c
254,4
-
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
C457
S-c
207
-
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
D455
S-c
254,4
A - C
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C466
S-c
254,4
-
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C466
S-c
207
-
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C468
S-c
254,4
-
30 min
F453
0,07
Output signal off immediately.
FL display off.
F453 opened after 10 sec.
No hazard.
FL display off.
F453 opened after 10 sec.
No hazard.
C468
S-c
207
-
30 min
F453
0,05
Output signal off immediately.
FL display off.
F453 opened after 20 min.
R453 damaged.
No hazard.
FL display off.
F453 opened after 20 min.
R453 damaged.
No hazard.
D469
S-c
254,4
A - C
30 min
F454,
F455
F455
2,80 A
FL display off after 9 sec.
F454, F455 opened.
Input current stabilised at 2,50A.
No hazard.
F454, F455 opened.
Input current stabilised at 2,50A.
No hazard.
C480
S-c
254,4
-
30 min
F454,
F455
F455
2,80 A
FL display off immediately.
F454, F455 opened.
Input current stabilised at 2,46A.
No hazard.
F454, F455 opened.
Input current stabilised at 2,46A.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 38 of 44 -
Order No.
200211174
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C480
S-c
207
-
30 min
F454,
F455
F455
2,43 A
FL display off immediately.
F454, F455 opened.
Input current stabilised at 2,22A.
No hazard.
F454, F455 opened.
Input current stabilised at 2,22A.
No hazard.
C481
S-c
254,4
-
3 hr
F454,
F455
F455
2,55 A
FL display off immediately.
Input current stabilised at 2,52A.
Sub transformer primary winding
heated-up to 59K and stabilised.
No hazard.
Input current stabilised at 2,52A.
Sub transformer primary winding
heated-up to 59K and stabilised.
No hazard.
D473
S-c
254,4
A - C
30 min
-
2,46 A
Normal operating.
No component damaged.
No hazard.
No component damaged.
No hazard.
C484
S-c
254,4
-
3 hr
F454,
F455
F455
2,56 A
FL display off immediately.
R455 opened.
Input current stabilised at 2,54A.
Sub transformer primary winding
heated-up to 69K and stabilised.
No hazard.
R455 opened.
Input current stabilised at 2,54A.
Sub transformer primary winding
heated-up to 69K and stabilised.
No hazard.
Q460
S-c
254,4
C - E
30 min
-
2,46 A
Normal operating.
No component damaged.
No hazard.
No component damaged.
No hazard.
Q460
S-c
254,4
B - C
30 min
-
2,46 A
Normal operating.
No component damaged.
No hazard.
No component damaged.
No hazard.
D476
S-c
254,4
A - C
30 min
-
2,46 A
Normal operating.
No component damaged.
No hazard.
No component damaged.
No hazard.
D506
S-c
254,4
AC - +
30 min
F452,
F501,
F502
F501,
F502
-
Normal operating.
F501 opened immediately.
Input current stabilised at 2,46A.
No hazard.
F501 opened immediately.
Input current stabilised at 2,46A.
No hazard.
C704
S-c
254,4
-
30 min
F452,
F501,
F502
F501,
F502
-
Protection circuit operated
immediately (
immediately (
RLY452, RLY453
off).
F501, F502 opened.
Input current stabilised at 0,02A.
No hazard.
Input current stabilised at 0,02A.
No hazard.
C704
S-c
207
-
30 min
F452,
F501,
F502
F501,
F502
-
Protection circuit operated
immediately (
immediately (
RLY452, RLY453
off).
F501, F502 opened.
Input current stabilised at 0,02A.
No hazard.
Input current stabilised at 0,02A.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 39 of 44 -
Order No.
200211174
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D514
S-c
254,4
A - C
30 min
F452,
F501,
F502
F501,
F502
2,46 A
Normal operating.
Input current stabilised at 2,46 A.
No component damaged.
No hazard.
Input current stabilised at 2,46 A.
No component damaged.
No hazard.
D507
S-c
254,4
AC - +
30 min
F452,
F503,
F504
F503,
F504
-
Normal operating.
F503 opened immediately.
Input current stabilised at 2,48A.
No hazard.
F503 opened immediately.
Input current stabilised at 2,48A.
No hazard.
C711
S-c
254,4
-
30 min
F452,
F503,
F504
F503,
F504
-
Output signal off immediately.
F503, F504 opened.
Input current stabilised at 0,83A.
No hazard.
F503, F504 opened.
Input current stabilised at 0,83A.
No hazard.
IC537
S-c
254,4
In - Out
30 min
F452,
F503,
F504
F503,
F504
2,50 A
Normal operating.
Input current stabilised at 2,50 A.
No component damaged.
No hazard.
Input current stabilised at 2,50 A.
No component damaged.
No hazard.
IC537
S-c
254,4
In - G
30 min
F452,
F503,
F504
F503,
F504
-
Protection circuit operated
immediately (
immediately (
RLY452, RLY453
off).
Input current stabilised at 0,02A.
No component damaged.
No hazard.
No component damaged.
No hazard.
C721
S-c
254,4
-
30 min
F452,
F503,
F504
F503,
F504
-
Protection circuit operated
immediately (
immediately (
RLY452, RLY453
off).
R792 opened.
Input current stabilised at 0,02A.
No hazard.
Input current stabilised at 0,02A.
No hazard.
C721
S-c
207
-
30 min
F452,
F503,
F504
F503,
F504
-
Protection circuit operated
immediately (
immediately (
RLY452, RLY453
off).
R792 opened.
Input current stabilised at 0,02A.
No hazard.
Input current stabilised at 0,02A.
No hazard.
D511
S-c
254,4
A - C
30 min
F452,
F505,
F506
F505,
F506
-
Normal operating.
F505 opened immediately.
Input current stabilised at 2,50A.
No hazard.
F505 opened immediately.
Input current stabilised at 2,50A.
No hazard.
C710
S-c
254,4
-
30 min
F452,
F505,
F506
F505,
F506
-
Normal operating.
F505, F506 opened immediately.
Input current stabilised at 2,47A.
No hazard.
F505, F506 opened immediately.
Input current stabilised at 2,47A.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 40 of 44 -
Order No.
200211174
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C710
S-c
207
-
30 min
F452,
F505,
F506
F505,
F506
-
Normal operating.
F505, F506 opened immediately.
Input current stabilised at 2,30A.
No hazard.
F505, F506 opened immediately.
Input current stabilised at 2,30A.
No hazard.
IC534
S-c
254,4
In - Out
30 min
F452,
F505,
F506
F505,
F506
2,48 A
Normal operating.
Input current stabilised at 2,48 A.
No component damaged.
No hazard.
Input current stabilised at 2,48 A.
No component damaged.
No hazard.
IC534
S-c
254,4
In - G
30 min
F452,
F505,
F506
F505,
F506
2,56 A
Normal operating.
Input current stabilised at 2,46 A.
R785 damaged.
No hazard.
Input current stabilised at 2,46 A.
R785 damaged.
No hazard.
C722
S-c
254,4
-
30 min
F452,
F505,
F506
F505,
F506
2,48 A
Normal operating.
Input current stabilised at 2,48 A.
No component damaged.
No hazard.
Input current stabilised at 2,48 A.
No component damaged.
No hazard.
D508
S-c
254,4
AC - +
30 min
F452,
F507,
F508
F507,
F508
-
Normal operating.
F507 opened immediately.
Input current stabilised at 2,44A.
No hazard.
F507 opened immediately.
Input current stabilised at 2,44A.
No hazard.
C709
S-c
254,4
-
30 min
F452,
F507,
F508
F507,
F508
-
Normal operating.
F507, F508 opened immediately.
Input current stabilised at 2,47A.
No hazard.
F507, F508 opened immediately.
Input current stabilised at 2,47A.
No hazard.
C709
S-c
207
-
30 min
F452,
F507,
F508
F507,
F508
-
Normal operating.
F507, F508 opened immediately.
Input current stabilised at 2,25A.
No hazard.
F507, F508 opened immediately.
Input current stabilised at 2,25A.
No hazard.
IC536
S-c
254,4
In - Out
30 min
F452,
F507,
F508
F507,
F508
2,47 A
Normal operating.
Input current stabilised at 2,47 A.
No component damaged.
No hazard.
Input current stabilised at 2,47 A.
No component damaged.
No hazard.
IC536
S-c
254,4
In - G
30 min
F452,
F507,
F508
F507,
F508
2,54 A
Normal operating.
Input current stabilised at 2,43 A.
R789 opened.
No hazard.
Input current stabilised at 2,43 A.
R789 opened.
No hazard.
C720
S-c
254,4
-
30 min
F452,
F507,
F508
F507,
F508
2,47 A
Normal operating.
Input current stabilised at 2,45 A.
R786 damaged.
No hazard.
Input current stabilised at 2,45 A.
R786 damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.