Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate ▷ View online

 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
20.2.2 
Internal fire enclosures with openings 
not exceeding 1 mm in width and 
with openings for wires completely 
filled   
No internal fire enclosure. 
20.2.3 
Requirements of 20.2.1 and 20.2.2 
met by an internal fire enclosure   
 
 
ANNEX A, ADDITIONAL 
REQUIREMENTS FOR 
APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER   
Not intended for outdoor use. 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 
5.4.1 a) does not apply   
 
A.10.2.1 
Enclosure provides protection 
against splashing water   
 
A.10.2.2 
Humidity treatment carried out for 
7 days   
 
 
ANNEX B, APPARATUS TO BE 
CONNECTED TO THE 
TELECOMMUNICATION 
NETWORKS   
Not intended for telecommunication networks 
B.5.4.1 
e) Where the separation of TNV 
circuits from other circuits relies on 
protective earthing the instructions 
make it clear that protective earthing 
is essential   
 
B.8.1 
TNV circuits separated from the 
mains circuit and from hazardous 
live parts by either: 
 
 
 
a) double or reinforced insulation   
 
 
b) basic insulation with earthed 
protective screening   
 
B.8.2 
TNV circuits separated from circuits 
other than those in B.8.1 and from 
accessible conductive parts by basic 
insulation meeting the requirements 
for clearances and creepage 
distances for the voltages concerned   
 
B.9.1.1 
TNV circuit terminals contacts which 
cannot be touched by probe B.1, 
exempt from the requirements 
inaccessible terminal contacts in 
9.1.1   
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1   
 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage   
 
 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
 
Main 
transformer 
 
Cross-over 
tubing Mtl. 
 
Thermal fuse 
cut-out 
Power Technics Co. 
 
 
Daikin Industries Co. 
 
 
Seki Controls Co. Ltd. 
55286170NR 
 
 
PTFE tube 
 
 
ST-22 
230V, Class E 
 
 
180C, 94V-0 
Min 0,5mm thick 
 
5A/250V
, 145C
 
IEC60065 
clause 14.3 
 
UL94 
 
 
IEC60730 
1.) 
 
 
UL 
 
 
VDE 
T451 
Standby 
transformer 
 
Bobbin Mtl. 
alt. 
 
Thermal fuse 
Han Young Electronics 
   
 
E.I. Dupont. 
Sam Yang Co., Ltd. 
 
Tamura Kaken Co. 
(Anzen Dengu Co.) 
55286320NR 
 
 
FR-530 
2550GN30 
 
VS13 
230V, Class E 
 
 
Min. 94V-0 
 
 
136C, 250V, 1A 
IEC60065 
clause 14.3 
 
UL94 
 
 
IEC60691 
1.) 
 
 
UL 
 
 
VDE 
T452 
Sub 
transformer 
 
Bobbin Mtl. 
alt. 
 
Thermal fuse 
Han Young Electronics 
   
 
E.I. Dupont. 
Sam Yang Co., Ltd. 
 
Tamura Kaken Co. 
(Anzen Dengu Co.) 
5528634ANR 
 
 
FR-530 
2550GN30 
 
VS13 
230V, Class E 
 
 
Min. 94V-0 
 
 
136C, 250V, 1A 
IEC60065 
clause 14.3 
 
UL94 
 
 
IEC60691 
1.) 
 
 
UL 
 
 
VDE 
IL451 
A
ppliance 
inlet
 
I-SHENG 
7014 
10A / 250V~ 
IEC60320 
N, VDE 
Sec. 
componen
Line filter 
Power Technics Co. 
55411860NR 
500uH x 2, 
Class E 
IEC60065 
clause 14.3 
1.) 
 
Mains plug   
with cord 
Not evaluated, ref. 
Summary of testing 
   
   
   
   
SW451 
Mains switch 
Matsushita Electronic. 
Y1 
(ESB91511A) 
8A/128A 250V 
IEC60065 
IEC61058-1 
N, VED 
RLY451 
RLY452 
RLY453 
Mains relay 
 
Original 
Electromech.
 
SDT-S-112DMR 
8A/120A 250V 
IEC61058-1 
IEC 60065 
F451 
F454, 
F455, 
F501, 
F502 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T1.6A L 250V 
IEC60127 
S, VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued) 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
F452 
Mains fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T6.3A L 250V 
IEC60127 
S, VDE 
F453 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T500mA L 
250V 
IEC60127 
S, VDE 
F503, 
F504, 
F507, 
F508 
Mains fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T3.15A L 250V 
IEC60127 
S, VDE 
F505, 
F506 
Fuse 
alt. 
alt. 
alt. 
Littelfuse Triad Inc. 
Schurter AG. 
Samjoo Enterprise. 
Sun Electric Co. Ltd. 
50T, 5x20mm 
FST, 5x20mm 
50T, 5x20mm 
5T, 5x20mm 
T1.25A L 250V 
IEC60127 
S, VDE 
C450, 
C459 
X-capacitor 
alt. 
alt. 
alt. 
alt. 
alt. 
Pilkor Electronics. 
Pilkor Electronics. 
ISKRA Elect. 
Okaya Electric Inc. 
Yuchang Electronics. 
Ultra Tech Xiphi. 
PCX2 335M 
PCX2 335 
KNB1530 
RE104 
WBU1942 
HXQ 
0.10uF 275V 
X2 
IEC60384-
14, 2
nd
 ed. 
S, VDE 
 
C451, 
C486. 
C487, 
C488, 
C489, 
X-capacitor 
alt. 
alt.   
alt. 
alt. 
Korea Electronics 
Netron Tech. 
Sam Wha Capacitor. 
JYH CHUNG 
Murata Mfg. 
NU 
AA 
SC 
JY 
KH 
0.0047uF/250V 
X1/Y2 
IEC60384-
14, 2
nd
 ed. 
S, VDE 
R451 
Bridging 
resistor for 
mains relay 
D. I. Electronics Co. 
RQD 
10 
 / 30W, 
IEC60065 
clause 14.1 
1.) 
 
Mains 
socket-outlet 
Dae Ryung Electronic 
A3-02-D006 
2.5A/250V 
IEC 60884-1 
 
PCB 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Comments 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
Page of 55
Display

Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.