Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 21 of 44 -
Order No.
200211174
14.3
Inductors and windings
P
14.3.1
Transformers and inductors marked
with manufacturer's name and type
with manufacturer's name and type
Type:
“55286170NR” for Main transformer,
“5528634ANR” for Sub transformer,
”55286320NR” for Standby transformer.
Manufacturer’s name identification:
“POWER TECHNICS CO.” for Main transformer,
”KS” for Sub and standby transformers.
“55286170NR” for Main transformer,
“5528634ANR” for Sub transformer,
”55286320NR” for Standby transformer.
Manufacturer’s name identification:
“POWER TECHNICS CO.” for Main transformer,
”KS” for Sub and standby transformers.
P
14.3.2.
Transformer category
Isolating transformer
P
14.3.3-5
Transformer construction
See below.
P
14.3.3.2
Transformers meet the
constructional requirements :
constructional requirements :
See below.
P
Transformer/motor
Insulation
Insulation
Test
Flashover
Creepage distances
Part No/markings
between
resistance
voltage
Breakdown
and clearances
M Ohm
kV(60)s
voltage kV
Measured
Required
55286170NR
Pr - sec
> 100
3KV(rms)
-
> 8,0 mm
> 6 mm
5528634ANR
Pr - ic - sec
> 100
3KV (rms)
-
> 6,0 mm
> 6 mm
55286320NR
Pr - ic - sec
> 100
3KV (rms)
-
> 7,4 mm
> 6 mm
Components / construction
(Main transformer)
Concentric winding on an isolate iron core. At least 3
layers of insulation between primary and secondary
winding.
layers of insulation between primary and secondary
winding.
P
Components / construction
(Sub/Standby transformer)
Windings on two separate bobbins. The bobbins are
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness : > 0,4mm.
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness : > 0,4mm.
P
Transformer/mot
or
or
Insulation
Thickness (mm)
Material
Dielectric strength test
Part
No/markings
No/markings
between
X
for each combination of
Number
two (2) layers
55286170NR
Pr - sec
0,05 mm x 3
Polyester film
Pass *)
Pr - sec
0,5 mm x 1
P.T.F.E. Tube
Pass *)
5528634ANR
Pr - sec
0,80 mm min. x 1
PETP bobbin
Pass *)
Pr - ic
0,80 mm min. x 1
PETP bobbin
Pass *)
55286320NR
Pr - sec
0,80 mm min. x 1
PETP bobbin
Pass *)
Pr - ic
0,80 mm min. x 1
PETP bobbin
Pass *)
*) Test voltage: 3000 Vrms.
-
IEC 60065, 6th edition : 1998
-
- Page 22 of 44 -
Order No.
200211174
14.3.4.1
Class II transformers have adequate
separation between hazardous live
windings and windings intended to
be connected to accessible
conductive parts (double or
reinforced insulation)
separation between hazardous live
windings and windings intended to
be connected to accessible
conductive parts (double or
reinforced insulation)
Double or reinforced insulation between primary and
secondary windings according to clause 8.8.
secondary windings according to clause 8.8.
P
Coil formers and partition walls
≥
0,4 mm
The Sub and Standby transformer bobbin fulfils the
requirement of reinforced insulation, see table above for
bobbin thickness.
requirement of reinforced insulation, see table above for
bobbin thickness.
P
14.3.4.2
Class I transformers, with basic
insulation and protective screening
only if all 7 conditions of 14.3.4.2 are
met
insulation and protective screening
only if all 7 conditions of 14.3.4.2 are
met
N
14.3.4.3
Separating transformers with at least
basic insulation
basic insulation
N
14.3.5.1
Class II transformers have adequate
insulation between hazardous live
parts and accessible parts (double
or reinforced insulation)
insulation between hazardous live
parts and accessible parts (double
or reinforced insulation)
Double or reinforced insulation between hazardous live
windings and accessible conductive parts.
windings and accessible conductive parts.
P
Coil formers and partition walls
≥
0,4 mm
The Sub and Standby transformer bobbin fulfils the
requirement of reinforced insulation, see table above for
bobbin thickness.
requirement of reinforced insulation, see table above for
bobbin thickness.
P
14.3.5.2
Class I transformers have adequate
insulation between hazardous live
parts and accessible conductive
parts or those conductive parts or
protective screens connected to a
protective earth terminal
insulation between hazardous live
parts and accessible conductive
parts or those conductive parts or
protective screens connected to a
protective earth terminal
N
Winding wires connected to
protective earth have adequate
current-carrying capacity
protective earth have adequate
current-carrying capacity
N
14.4
High voltage components
N
High-voltage components and
assemblies: U > 4 kV (peak)
separately approved
assemblies: U > 4 kV (peak)
separately approved
No high voltage components used
N
Component meets category FV 1 of
IEC 60 707
IEC 60 707
N
14.4.1
High voltage transformers and
multipliers tested as part of the
submission
multipliers tested as part of the
submission
N
14.5
Protective devices
P
Protective devices used within their
ratings
ratings
Thermal cut-out, thermal links and fuses
P
-
IEC 60065, 6th edition : 1998
-
- Page 23 of 44 -
Order No.
200211174
External clearance and creepage
distances appropriate for the voltage
across the device when opened
distances appropriate for the voltage
across the device when opened
P
14.5.1.1
a) Thermal cut-outs separately
approved
approved
Automatic:
Manuf.: Seki Controls Co., Ltd.
Type: ST-22
Certified by: VDE
Manuf.: Seki Controls Co., Ltd.
Type: ST-22
Certified by: VDE
P
b) Thermal cut-outs tested as part of
the submission
the submission
N
14.5.1.2
a) Thermal links separately approved
Manuf.: Tamura Kaken (Anzen Dengu Co.)
Type: VS13
Certified by: VDE
According to IEC60691
Type: VS13
Certified by: VDE
According to IEC60691
P
b) Thermal links tested as part of the
apparatus
apparatus
N
14.5.1.3
Thermal devices resettable by
soldering
soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit
according to IEC 60 127
according to IEC 60 127
See list below
P
Circuit
Manufacturer
Dimen-
Approved
Marking of
Marking
Current
diagram
sions
by
rated current,
close to
through
informa-
pre-arcing time
the com-
the fuse
tion
and current
ponent
in normal
Part No
characteristic
operation
F451
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T1,6A L 250V
T1,6A L 250V
< 0,80 A
F452
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T6,3A L 250V
T6,3A L 250V
< 2,46 A
F453
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T500mA L 250V
T500mA L 250V
< 0,48 A
F454, F455
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T1,6A L 250V
T1,6A L 250V
< 0,70 A
F501, F502
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T1,6A L 250V
T1,6A L 250V
< 0,38 A
F503, F504
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T3,15A L 250V
T3,15A L 250V
< 0,94 A
F505, F506
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T1.25A L 250V
T1.25A L 250V
< 0,37 A
F507, F508
Littelfuse Triad Inc.
5
× 20mm, 50T S, VDE
T3,15A L 250V
T3,15A L 250V
< 0,90 A
14.5.2.2
Correct marking of fuse-links
adjacent to holder
adjacent to holder
Correct marking applied close to the fuse, see table
above.
above.
P
14.5.2.3
Not possible to connect fuses in
parallel
parallel
No fuse holder so designed that fuse-links can be
connected in parallel
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live
parts when replacing fuse-links
without the use of a tool
parts when replacing fuse-links
without the use of a tool
No replacement of fuse possible by hand.
P
14.5.3
PTC-S thermistors comply with
IEC 60 738
IEC 60 738
No PTC’s
N
-
IEC 60065, 6th edition : 1998
-
- Page 24 of 44 -
Order No.
200211174
PTC-S devices (>15 W) category
FV 1 or better
FV 1 or better
N
14.5.4
Other protective devises.
Circuit protectors have adequate
breaking capacity and their position
is correctly marked
Circuit protectors have adequate
breaking capacity and their position
is correctly marked
No other protective devices
N
14.6
Switches
P
Manually operated mechanical
switch (MOMS) conductively
connected to the mains
switch (MOMS) conductively
connected to the mains
P
Part No
Function
Manufacturer
Type
Rated
Marking
Marking
All-
One
Name
Trademark
V
A
Surge
pole
pole
current
SW451
x
Matsushita Electronic
M
Y1 (ESB91511A)
250
8
128A
RLY451,
RLY452,
RLY453
RLY452,
RLY453
x
Original Electromecha.
OEG
SDT-S-112DMR
250
8
120A
14.6.1
Permanently connected equipment
provided with an all-pole mains
switch unless 5.4.2 is met
provided with an all-pole mains
switch unless 5.4.2 is met
Apparatus is not permanently connected
N
14.6.2
Manually operated mechanical
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
Yes. MOMS required. See table above.
P
Switch readily accessible and not in
mains cord
mains cord
Switch located on the front and readily accessible
P
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical
switch (MOMS): Switch indication /
On position clearly discernible
switch (MOMS): Switch indication /
On position clearly discernible
The display is illuminated.
P
Indication by marking meets Cl. 5
Yes
P
Indication of the OFF position
Off-position marked with “OFF”
P
14.6.4
Manually operated mechanical
switch (MOMS) fitted. Is there a
Stand-by mode
switch (MOMS) fitted. Is there a
Stand-by mode
Yes
P
Stand-by mode clearly discernible
LED indication
P