Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 17 of 44 -
Order No.
200211174
11.2.1
Measurement of temperature rises
See appended table, fault condition tests
P
11.2.2
Temperature rise of accessible parts
See appended table, fault condition tests
P
11.2.3
Temperature rise of parts, other than
windings, providing electrical insulation
windings, providing electrical insulation
See appended table, fault condition tests
P
Temperature rise of printed circuit boards
(PCB) exceeding the limits of Table 2 by
max. 100 K for max. 5 min
(PCB) exceeding the limits of Table 2 by
max. 100 K for max. 5 min
No area where temperature exceeds 100K above
limits
limits
P
a) Temperature rise of printed circuit
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
No area where temperature exceeds 100K above
limits
limits
P
b) Temperature rise of printed circuit
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
No area where temperature exceeds 300K above
limits
limits
P
Meets all the special conditions if
conductors on printed circuit boards are
interrupted
conductors on printed circuit boards are
interrupted
No conductors are interrupted/peeled/loosened during
fault conditions
fault conditions
N
11.2.4
Temperature rise of parts acting as a
support or mechanical barrier
support or mechanical barrier
Temperature rises are within the limits.
P
11.2.5
Temperature rise of windings
See Fault Condition tests
P
11.2.6
Temperature rise of parts not subject to
the limits of 11.2.1 to 11.2.5,
table 2 item e).
the limits of 11.2.1 to 11.2.5,
table 2 item e).
No excessive temperature observed/measured on
other parts.
other parts.
P
12
MECHANICAL STRENGTH
P
12.1.1
Bump test (>7kg)
No damage in the sense of this standard
P
12.1.2
Vibration test (portable, musical
amplifiers, metal enclosure)
amplifiers, metal enclosure)
Assessed to be satisfactory constructed.
N
12.1.3
Impact test (0.5J)
No damage in the sense of this standard
P
12.2
Fixing of knobs, push buttons, keys and
levers
levers
Normal use will not impair the protection against
electric shock.
electric shock.
P
12.3
Remote controls with hazardous live
parts
parts
No remote control containing hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing
isolation
isolation
No antenna socket which insolate hazardous live
parts from accessible parts.
parts from accessible parts.
N
-
IEC 60065, 6th edition : 1998
-
- Page 18 of 44 -
Order No.
200211174
13
CLEARANCES AND CREEPAGE
DISTANCES
DISTANCES
P
13.1.1
Clearances and creepage distances in
accordance with 13.2 (fig. 9); minimum
distance
accordance with 13.2 (fig. 9); minimum
distance
See 13.2
P
Reduction applied if the 3 conditions are
met
met
Reduction of 1,0mm in clearance/creepage distance
for reinforced between live pcb pattern and RY451
connected secondary pcb pattern
for reinforced between live pcb pattern and RY451
connected secondary pcb pattern
.
P
Reduction applied for Grade 2 winding
wire
wire
No
N
13.1.2
Use of cemented joints
No cemented joints
N
Tests to confirm cemented joints
N
13.2
Class I apparatus
Class II apparatus
N
Creepage distances and clearances
between live parts and safety earthed
parts (basic insulation)
between live parts and safety earthed
parts (basic insulation)
N
Creepage distances and clearances
between live parts and not safety earthed
accessible parts (reinforced or double
insulation)
between live parts and not safety earthed
accessible parts (reinforced or double
insulation)
N
Class II apparatus
P
Creepage distances and clearances
between live parts and not accessible
parts (basic insulation)
between live parts and not accessible
parts (basic insulation)
N
Creepage distances and clearances
between not accessible parts and
accessible parts (supplementary
insulation)
between not accessible parts and
accessible parts (supplementary
insulation)
N
Creepage distances and clearances
between live parts and accessible parts
(reinforced or double insulation)
between live parts and accessible parts
(reinforced or double insulation)
Measured minimum distances:
5,0 mm (pr-sec)
6,0 mm (pr-accessible parts)
5,0 mm (pr-sec)
6,0 mm (pr-accessible parts)
P
Creepage distances and clearances
measured whilst forces of 2N and 30N
are applied
measured whilst forces of 2N and 30N
are applied
No reduction of clearance/creepage distances when
2N is applied on internal parts and 30N at the
enclosure.
2N is applied on internal parts and 30N at the
enclosure.
P
Clearances and creepage distances of
parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
Measured minimum distances: > 3,5 mm
P
Clearances and creepage distances
between conductors on printed circuit
boards, one of which may be
conductively connected to the mains, as
in fig. 10 (overheating only)
between conductors on printed circuit
boards, one of which may be
conductively connected to the mains, as
in fig. 10 (overheating only)
No overheating of conductors on PWB.
P
-
IEC 60065, 6th edition : 1998
-
- Page 19 of 44 -
Order No.
200211174
13.3
Enclosed, enveloped or hermetically
sealed parts: clearances and creepage
distances to Table 4
sealed parts: clearances and creepage
distances to Table 4
No such parts in the apparatus
N
13.4
Parts filled with insulating compound,
meeting the requirements of 8.8
meeting the requirements of 8.8
No components or subassemblies filled with
compound.
compound.
N
13.5
Type B coated printed circuit boards
complying with IEC 60 664-3 (basic
insulation only)
complying with IEC 60 664-3 (basic
insulation only)
No type B coated PWB
N
-
IEC 60065, 6th edition : 1998
-
- Page 20 of 44 -
Order No.
200211174
14
COMPONENTS
P
14.1
Resistors
P
a) Resistors between hazardous live
parts and accessible metal parts, or
bridging contact gaps on mains switch.
parts and accessible metal parts, or
bridging contact gaps on mains switch.
R451, 10 ohms, 30W;
Bridging contact gaps on mains relay RLY453.
After 21 days damp heat/10kV discharge test, the
value of resistance, not differ 2% from the original
value. OK.
See List of Critical Components.
Bridging contact gaps on mains relay RLY453.
After 21 days damp heat/10kV discharge test, the
value of resistance, not differ 2% from the original
value. OK.
See List of Critical Components.
P
b) Resistors, other than between
hazardous live parts and accessible
parts
hazardous live parts and accessible
parts
No such resistors
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes, see below
P
14.2.1
Y capacitors tested to IEC 384-14, 2nd
edition
edition
N
14.2.2
X capacitors tested to IEC 384-14, 2nd
edition
edition
Capacitor C450, C459 is X2, and
Capacitors C451, C486, C487, C488, C489 is X1.
Capacitors C451, C486, C487, C488, C489 is X1.
P
Part No
Manufacturer
Value
Type
Marking
Approved by
C450, C459
Pilkor Elect.
0.10 uF 275V
PCX2 335M
100nM 275V~X2
S, VDE
C451, C486,
C487, C488,
C489
C487, C488,
C489
Korea Electronics.
0.0047 uF 250V
NU
472M, X1/Y2
S, VDE
14.2.3
Capacitors operating at mains
frequency but not connected to the
mains: tests for X2
frequency but not connected to the
mains: tests for X2
No such capacitors
N
14.2.5
Capacitors with volume exceeding
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
No such capacitors
N
Capacitors with volume exceeding
1750 mm³, mounted closer to a
potential ignition source than Table 5
permits: compliance with
IEC 60 384-1, 4.38 category B or
better
1750 mm³, mounted closer to a
potential ignition source than Table 5
permits: compliance with
IEC 60 384-1, 4.38 category B or
better
No such capacitors
N
Shielded by a barrier to FV 0 or
metal
metal
No barrier required. See above.
N