Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 6 of 39 -
Order
No.
200245266
Hazardous live terminals,
instructions for wiring
instructions for wiring
No live terminal.
N
Instructions for replacing lithium
battery
battery
No lithium battery
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No explanation required (indication in the form of
illumination)
illumination)
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF from
the mains, info required
connected equipment
If not completely switched OFF from
the mains, info required
The apparatus is not for permanent connection
N
6 HAZARDOUS
RADIATION
No radiation
N
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
N
6.2.1
Opening of any cover by hand
N
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
N
Labelling
N
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
N
Warning label requirement
N
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
In OFF/Stand-by position, the power consumption is less
than 15W.
than 15W.
P
Surge current needed in clause 14.6
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
when testing mains switches or
functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
Ref. clause 14.6.
P
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 39 -
Order
No.
200245266
7.1
Standby mode:
U
=
207,0
V, I
=
0,029
A, P
=
5,7
W
Pout =
W
U
=
230,0
V, I
=
0,032
A, P
=
6,9
W
Pout =
W
U
=
254,4
V, I
=
0,042
A, P
=
8,7
W
Pout =
W
Measured at maximum non-clipped output:
U
=
207,0
V, I
=
4,53
A, P
=
800
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
U
=
230,0
V, I
=
4,75
A, P
=
931
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
U
=
254,4
V, I
=
4,80
A, P
=
1027
W
Pout =
2 x 67,6
W
(F)
1 x 66,8
W
(C)
2 x 66,4
W
(S)
2 x 66,1
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Measured at 1/8 of maximum non-clipped output:
U
=
207,0
V, I
=
2,16
A, P
=
349
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
U
=
230,0
V, I
=
2,21
A, P
=
392
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
U
=
254,4
V, I
=
2,25
A, P
=
439
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 39 -
Order
No.
200245266
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output):
U
=
254,4
V, I
=
2,25
A, P
=
439
W
Pout =
2 x 8,45
W
(F)
1 x 8,35
W
(C)
2 x 8,30
W
(S)
2 x 8,26
W
(S/W)
LSL =
5 x 8
Ω
Ω
Ω
Ω
Marking of loudspeaker terminals
“
SPEAKERS (8
Ω)
:
SR, SL, FR, FL”
”SPEAKERS (8
Ω)
:
CTR, SBR/MILTI R, SBL/MILTI L”
U =
254,4
V
4 Ohm
8 Ohm
16 Ohm
Ohm
Left
right
left
right
left
right
left
right
Measured max. output voltage in Vp
F)
32,9
C) 32,7
S) 32,6
S/W) 32,5
S) 32,6
S/W) 32,5
F) 32,9
C) -
S) 32,6
S/W) 32,5
C) -
S) 32,6
S/W) 32,5
Measured max. output power in W
F)
67,6
C) 66,8
S) 66,4
S/W) 66,1
S) 66,4
S/W) 66,1
F) 67,6
C) -
S) 66,4
S/W) 66,1
C) -
S) 66,4
S/W) 66,1
Measured max. mains power in W
1027
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible parts
(see table next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table next page)
P
7.1.3
Temperature rise of parts acting as a
support or as a mechanical barrier
support or as a mechanical barrier
(see table next page)
P
7.1.4
Temperature rise of windings
(see table next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table next page)
P
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 39 -
Order
No.
200245266
HEATING
∆
t = ( R2 - R1) x (234,5 + t1) - (t2 - t1)
R1
P
t1 =
24,9 °C
24,9 °C
t2 =
24,3 °C
24,9 °C
Test voltage
207 V
254,4 V
Winding
R1/
Ω
R2/
Ω
∆
t measured
∆
t allowed *)
Insulation
class
class
Main transf. pr. winding (207V)
2,048
2,569
66,6
85
Class E
Main transf. pr. winding (254,4V)
2,048
2,636
74,5
85
Class E
Sub transf. pr. winding (207V)
728
835
38,7
85
Class E
Sub transf. pr. winding (254,4V)
728
896
59,9
85
Class E
Other measured parts
∆
t measured
at 207V
∆
t measured
at 254,4V
∆
t allowed *)
Main transformer core
45,0
49,1
85
Sub transformer core
27,2
39,1
85
Diode, D201 body
50,2
55,9
-
PWB near D201
28,2
32,3
85
Diode, D501 body
48,1
50,6
-
PWB near D501
42,8
44,8
85
Diode, D502 body
19,7
20,8
-
Diode, D503 body
22,1
24,0
-
E. Capacitor, C202 body
21,4
25,1
-
E. Capacitor, C505 body
24,6
26,6
-
Regulator, IC55 body
35,4
47,3
-
Regulator, IC55 heat-sink
32,6
46,3
-
Bias TR, Q314 body
45,1
50,0
-
Power TR, Q317 body
46,3
51,5
-
Power TR, Q318 body
48,2
54,4
-
Power TR, Q319 body
48,1
54,1
-
PWB near Q319
27,4
30,5
85
Power TR, Q329 body
53,7
60,6
-
Click on the first or last page to see other AVR 4550 service manuals if exist.