Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 23 of 39 -
Order
No.
200245266
14.6.6.b.
Manually operated mechanical
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
Flame test for mains switches
N
14.6.7 Endurance
test
N
14.6.8
Temperature rise in mains switch
N
14.6.9
Dielectric strength test
N
14.6.10
Surge current for mains switches
also controlling mains socket-outlets
also controlling mains socket-outlets
Measured surge current for,
- Mains switch : < 1A peak.
- Mains relay
- Mains switch : < 1A peak.
- Mains relay
: < 37A peak + 20A peak* for 50W
Rated surge current for,
- Mains switch: 80A
: OK
- Mains relay, SK11: 120A.
: OK
*) Calculated surge current for switched socket outlet.
P
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to be
changed accidentally
changed accidentally
No voltage selector
N
14.9 Motors
P
14.9.1
Endurance test on motors
Only DC low voltage secondary connected motors for fan,
no further testing required.
no further testing required.
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
N
14.9.3
Protection against moving parts
No moving parts
N
14.9.4
Motors with phase-shifting
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of
accumulation of flammable gases
accumulation of flammable gases
No batteries
N
14.10.2
No possibility of recharging non-
rechargeable batteries
rechargeable batteries
N
-
IEC 60065, 6th edition : 1998
-
- Page 24 of 39 -
Order
No.
200245266
14.10.3
Recharging currents and times
within manufacturers limits
within manufacturers limits
N
Lithium batteries discharge and
reverse currents within the
manufacturers limits
reverse currents within the
manufacturers limits
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
No optocouplers.
N
Internal and external dimensions to
13.1.1
13.1.1
N
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer
Type Standard
Certified
Remarks
sheet
by
(colour
etc.)
Appliance inlet
I-SHENG
7014
IEC 60320
VDE
Black, 10A 250V
Mains
socket- outlet
socket- outlet
Dae Ryung Electronic
A3-04-D007
IEC 60884-1
NEMKO
Black, 2.5A 250V~
Mains sockets and interconnection
couplers
couplers
The socket outlet on the Class II apparatus does only
permit connection of other Class II apparatus.
permit connection of other Class II apparatus.
P
Overload protection for
socket-outlets
socket-outlets
Overload protection provided with a fuse:
F102, T3.15A L 250V
F102, T3.15A L 250V
P
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Only phono/RCA, Optical, Mini jack, Antenna, S-video,
A-BUS and RS-232 terminal used. Banana plug type
speaker terminal also used, but they are accepted due to
below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
A-BUS and RS-232 terminal used. Banana plug type
speaker terminal also used, but they are accepted due to
below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
-
IEC 60065, 6th edition : 1998
-
- Page 25 of 39 -
Order
No.
200245266
15.2
Provision for protective earthing
N
Accessible conductive parts of
Class I equipment reliably connected
to earth terminal, within equipment.
Class I equipment reliably connected
to earth terminal, within equipment.
N
Switches or fuses in protective earth
circuits
circuits
N
Class I supply apparatus with non-
hazardous live output voltage: output
circuit not connected to earth
hazardous live output voltage: output
circuit not connected to earth
N
Protective earth conductors correctly
coloured
coloured
N
Permanently connected apparatus
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
N
Protective earth connection of a part
removable by hand.
removable by hand.
N
Protective earth terminal resistant to
corrosion
corrosion
N
Earth resistance (
Ω
) test:
≤
0,1
Ω
at
25 A
N
15.3.
Terminals for external flexible cords
and for permanent connection to the
mains supply
and for permanent connection to the
mains supply
P
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
Apparatus is not for permanent connection.
N
15.3.2
Reliable connection of non-
detachable cords:
detachable cords:
Appliance inlet provided
N
Connection of the non-detachable
cord
cord
N
Soldered to conductors of a printed
circuit board
circuit board
N
Adequate clearances and creepage
distances between connections
should a wire break away
distances between connections
should a wire break away
N
Wire secured by additional means
N
15.3.3
Screws and nuts clamping external
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
No screws and nuts clamping
N
-
IEC 60065, 6th edition : 1998
-
- Page 26 of 39 -
Order
No.
200245266
15.3.4
Soldered conductors wrapped
around terminal prior to soldering or
held in place by additional means
around terminal prior to soldering or
held in place by additional means
Appliance inlet provided
N
Clamping of conductor and
insulation if not soldered or held by
screws
insulation if not soldered or held by
screws
N
15.3.5
Terminals for external flexible cords
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the
equipment
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the
equipment
Terminals have adequate connection capacity.
P
15.3.6
Terminals to 15.3.3 have sizes
required by Table 8
required by Table 8
The terminals have adequate size according to table 8
P
15.3.7
Terminals clamp conductors
between metal surfaces
between metal surfaces
Terminals have adequate pressure without damage the
conductor.
conductor.
P
Terminals designed to avoid
conductor slipping out when
tightened or loosened
conductor slipping out when
tightened or loosened
Adequate construction
P
Terminals adequately fixed to avoid
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
Terminals adequately fixed and clearances and creepage
are not reduced blow required values.
No stress on internal wiring.
are not reduced blow required values.
No stress on internal wiring.
P
15.3.8
Terminals carrying a current more
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
No contact pressure transmitted through insulating
material.
material.
P
15.3.9
Termination of non-detachable
cords: wires terminated near to each
other
cords: wires terminated near to each
other
Appliance inlet provided
N
Terminals located and shielded: test
with 8 mm strand
with 8 mm strand
N
15.4
Devices forming a part of the mains
plug
plug
N
15.4.1
No undue strain on mains socket-
outlets
outlets
The apparatus is not a device forming a part of the mains
plug.
plug.
N
15.4.2
Device complies with standard for
dimensions of mains plugs
dimensions of mains plugs
N
15.4.3.
Device has adequate mechanical
strength (tests a,b,c)
strength (tests a,b,c)
N