Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 15 of 39 -
Order
No.
200245266
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (M
Ω
) at least
2 M
Ω
min. after surge test for basic
and 4 M
Ω
min. for reinforced
insulation
>4 M
Ω
P
10.2
Humidity treatment 48 h or 120 h
120 h (40
°
C). No impairment
P
10.3
Insulation resistance and dielectric
strength
strength
P
Tested insulation
Insulation
Test voltage
Voltage test
Remarks
resistance
based on the
(r.m.s.value)
(M Ohm)
Operating
Meas-
Min.
Voltage
ured
required
(V)
(V)
Between the poles
For rated mains
of the circuit
:
> 2
2
voltages
≤
150V
directly connected
r.m.s, 1410V pk
to the supply
mains
2
For rated mains
1500 V
Pass
voltages
≥
150V
r.m.s, 2120V pk
Basic insulation
:
2
Curve A,
V
Fig.
7
Supplementary
insulation
:
2
Curve A,
V
Fig.
7
Reinforced
insulation
:
> 100
4
Curve B,
3000 V
Pass
Fig.
7
11 FAULT
CONDITIONS
P
11.1
Electric shock hazard under fault
conditions
conditions
No electric shock hazard under fault conditions
P
11.2
Heating under fault condition
P
No hazard from softening solder
Neither danger of fire to surroundings nor abnormal
heat developed
heat developed
P
No flaming more than 10s
No flaming
P
11.2.1
Measurement of temperature rises
See appended table, fault condition tests
P
11.2.2
Temperature rise of accessible parts
See appended table, fault condition tests
P
11.2.3
Temperature rise of parts, other than
windings, providing electrical insulation
windings, providing electrical insulation
See appended table, fault condition tests
P
Temperature rise of printed circuit
boards (PCB) exceeding the limits of
Table 2 by max. 100 K for max. 5 min
boards (PCB) exceeding the limits of
Table 2 by max. 100 K for max. 5 min
No area where temperature exceeds 100K above
limits
limits
P
-
IEC 60065, 6th edition : 1998
-
- Page 16 of 39 -
Order
No.
200245266
a) Temperature rise of printed circuit
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
No area where temperature exceeds 100K above
limits
limits
P
b) Temperature rise of printed circuit
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
No area where temperature exceeds 300K above
limits
limits
P
Meets all the special conditions if
conductors on printed circuit boards are
interrupted
conductors on printed circuit boards are
interrupted
No conductors are interrupted/peeled/loosened during
fault conditions
fault conditions
N
11.2.4
Temperature rise of parts acting as a
support or mechanical barrier
support or mechanical barrier
Temperature rises are within the limits.
P
11.2.5
Temperature rise of windings
See Fault Condition tests
P
11.2.6
Temperature rise of parts not subject to
the limits of 11.2.1 to 11.2.5,
table 2 item e).
the limits of 11.2.1 to 11.2.5,
table 2 item e).
No excessive temperature observed/measured on
other parts.
other parts.
P
12 MECHANICAL
STRENGTH
P
12.1.1
Bump test (>7kg)
No damage in the sense of this standard
P
12.1.2
Vibration test (portable, musical
amplifiers, metal enclosure)
amplifiers, metal enclosure)
Assessed to be satisfactory constructed.
N
12.1.3
Impact test (0.5J)
No damage in the sense of this standard
P
12.2
Fixing of knobs, push buttons, keys and
levers
levers
Normal use will not impair the protection against
electric shock.
electric shock.
P
12.3
Remote controls with hazardous live
parts
parts
No remote control containing hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing
isolation
isolation
No antenna socket which insolate hazardous live parts
from accessible parts.
from accessible parts.
N
13
CLEARANCES AND CREEPAGE
DISTANCES
DISTANCES
P
13.1.1
Clearances and creepage distances in
accordance with 13.2 (fig. 9); minimum
distance
accordance with 13.2 (fig. 9); minimum
distance
See 13.2
P
Reduction applied if the 3 conditions are
met
met
No reduction applied
N
Reduction applied for Grade 2 winding
wire
wire
No
N
13.1.2
Use of cemented joints
No cemented joints
N
Tests to confirm cemented joints
N
-
IEC 60065, 6th edition : 1998
-
- Page 17 of 39 -
Order
No.
200245266
13.2
Class I apparatus
Class II apparatus
N
Creepage distances and clearances
between live parts and safety earthed
parts (basic insulation)
between live parts and safety earthed
parts (basic insulation)
N
Creepage distances and clearances
between live parts and not safety earthed
accessible parts (reinforced or double
insulation)
between live parts and not safety earthed
accessible parts (reinforced or double
insulation)
N
Class II apparatus
P
Creepage distances and clearances
between live parts and not accessible
parts (basic insulation)
between live parts and not accessible
parts (basic insulation)
N
Creepage distances and clearances
between not accessible parts and
accessible parts (supplementary
insulation)
between not accessible parts and
accessible parts (supplementary
insulation)
N
Creepage distances and clearances
between live parts and accessible parts
(reinforced or double insulation)
between live parts and accessible parts
(reinforced or double insulation)
Measured minimum distances:
6,6 mm (pr-sec)
6,3 mm (pr-accessible parts)
6,6 mm (pr-sec)
6,3 mm (pr-accessible parts)
P
Creepage distances and clearances
measured whilst forces of 2N and 30N
are applied
measured whilst forces of 2N and 30N
are applied
No reduction of clearance/creepage distances when
2N is applied on internal parts and 30N at the
enclosure.
2N is applied on internal parts and 30N at the
enclosure.
P
Clearances and creepage distances of
parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
parts of different polarity directly
connected to the mains, as in fig. 9;
minimum distance
Measured minimum distances: > 4,3 mm
P
Clearances and creepage distances
between conductors on printed circuit
boards, one of which may be
conductively connected to the mains, as
in fig. 10 (overheating only)
between conductors on printed circuit
boards, one of which may be
conductively connected to the mains, as
in fig. 10 (overheating only)
No overheating of conductors on PWB.
P
13.3
Enclosed, enveloped or hermetically
sealed parts: clearances and creepage
distances to Table 4
sealed parts: clearances and creepage
distances to Table 4
No such parts in the apparatus
N
13.4
Parts filled with insulating compound,
meeting the requirements of 8.8
meeting the requirements of 8.8
No components or subassemblies filled with
compound.
compound.
N
13.5
Type B coated printed circuit boards
complying with IEC 60 664-3 (basic
insulation only)
complying with IEC 60 664-3 (basic
insulation only)
No type B coated PWB
N
-
IEC 60065, 6th edition : 1998
-
- Page 18 of 39 -
Order
No.
200245266
14 COMPONENTS
P
14.1 Resistors
N
a) Resistors between hazardous live
parts and accessible metal parts, or
bridging contact gaps on mains switch.
parts and accessible metal parts, or
bridging contact gaps on mains switch.
No resistors
N
b) Resistors, other than between
hazardous live parts and accessible
parts
hazardous live parts and accessible
parts
No resistors
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes, see below
P
14.2.1
Y capacitors tested to IEC 384-14, 2nd
edition
edition
N
14.2.2
X capacitors tested to IEC 384-14, 2nd
edition
edition
CA11 is X2, and
C118 is X1 capacitor.
C118 is X1 capacitor.
P
Part No
Manufacturer
Value
Type
Marking
Approved by
CA11
Pilkor Elect.
0.10 uF 275V
PCX2 335M
100nM 275V~X2
FIMKO
C118
Korea Electronics.
0.0047 uF 250V
NU
472M, X1/Y2
FIMKO
14.2.3
Capacitors operating at mains
frequency but not connected to the
mains: tests for X2
frequency but not connected to the
mains: tests for X2
No such capacitors
N
14.2.5
Capacitors with volume exceeding
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
No such capacitors
N
Capacitors with volume exceeding
1750 mm³, mounted closer to a
potential ignition source than Table 5
permits: compliance with
IEC 60 384-1, 4.38 category B or
better
1750 mm³, mounted closer to a
potential ignition source than Table 5
permits: compliance with
IEC 60 384-1, 4.38 category B or
better
No such capacitors
N
Shielded by a barrier to FV 0 or
metal
metal
No barrier required. See above.
N
14.3
Inductors and windings
P
14.3.1
Transformers and inductors marked
with manufacturer's name and type
with manufacturer's name and type
Type:
“55589450NR” for Main transformer,
“55643480NR” for Sub transformer.
Manufacturer’s name identification:
”SET” for Main transformer,
”DY” and “T” mark in circle for Sub transformer.
“55589450NR” for Main transformer,
“55643480NR” for Sub transformer.
Manufacturer’s name identification:
”SET” for Main transformer,
”DY” and “T” mark in circle for Sub transformer.
P
14.3.2. Transformer
category
Isolating transformer
P