IEC 60065, 6th edition : 1998
 - 
- Page 3 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
SUMMARY OF TESTING:
 
 
The apparatus complies with the requirements in IEC 60065:1998 and EN 60065:1998 
 
 
 
 
Clause Information/Remarks 
Comments 
7.1 
Heating 
Additional testing for tropical climate is performed for 
Singapore 
10.2 
Humidity treatment 
Additional testing for tropical climate is performed for 
Singapore 
14.5.2 
Fuse-links 
F501, F502, F503, F504, F505 and F506 are US 
approved type fuses that differ dimension with 
IEC60127, and positioned in secondary side of the 
apparatus. 
 
The mentioned above fuses shall be replaced by 
only with same rating and type of fuses as original 
fuses, when replacing it. 
15 and 16 
Plug / External flexible cord 
The equipment shall be provided with an approved 
mains plug and cord complying with the national 
regulations of the countries in which the appliance is 
to be sold. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 4 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
TEST REPORT INFORMATION 
It should be taken into account that this test report does not replace the text in the test specification. 
Only general tests have been mentioned in the pre-printed text. For complete tests and requirements we refer to the 
actual specification mentioned. 
IEC 60065, 6th edition:1998 
The meaning of certain marks and abbreviations (Voltages and currents are r.m.s. values unless otherwise specified) 
 
OK        = no remarks                 
pr       
= primary 
 
 
?      = unclear, borderline case  
sec   
= secondary 
 
 
t     = temperature rise      
pr-sec  
= primary-secondary 
 
 
tpr     = thermal paper       
pr-ss  
= primary-static screen 
 
 
h, m, s   = hour, minute, second       
pr-ic   
= primary-iron core 
 
 
U, I, P    = voltage, current, power   
pr-tra   
= primary-transformer encl. 
 
 
û,î     = peak value         
F    
= fuse   
 
 
n    
= rated   
PWB  
= printed wiring board 
 
 
     = issue considered 
LSL  
= loudspeaker load 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 5 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
Standardized approval marks   
 
 
1  
SCOPE   
According to the standard 
 
2  
DEFINITIONS 
According to the standard 
 
3  
GENERAL REQUIREMENTS  
According to the standard 
 
 
Safety class of the apparatus 
Class II 
 
4   
GENERAL CONDITIONS FOR 
TESTS  
According to the standard 
 
4.1.4 - 
4.2.12. 
Normal operating 
conditions/position/adjustments 
With all users controls set to obtain maximum power from 
the mains and at 1/8 of max. audio output power. 
Positioned according to users manual 
 
MARKING AND INSTRUCTIONS 
 
 
Copy of the markings :
 
 
 
 
SEE ATTACHED PHOTOS 
 
 
 
Comprehensible and easily 
discernible  
On front and rear side of the enclosure 
 
Permanent durability against water 
and petroleum spirit   
Tested with water / spirit 
 
5.1 
Identification, maker, model      
 
 
Class II symbol   
 
 
Rated supply voltage and symbol      
AC-symbol ( 
~
 ) 
230V 
 
Rated mains frequency 
50Hz 
 
Rated current or power consumption 
930W 
5.2 
Earth terminal   
Class II apparatus 
 
Hazardous live terminals   
No live parts accessible 
 
Supply output terminals (other than 
mains)  
The power is marked close to the socket outlet 
”AC OUTLETS, 230V~50Hz”   
”SWITCHED, 50W MAX” 
”UNSWITCHED, 100W MAX” 
5.3 
Use of triangle with exclamation 
mark         
         
(Symbol ISO 7000-0434)   
Correct symbol applied: Imprinted on rear side in 
connection with CAUTION of opening. Further; no 
incorrect use of this symbol is found. 
5.4 
Instructions for use   
 
5.4.1 
Mains powered equipment not 
exposed to dripping or splashing   
Adequate instructions supplied. 
   
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 6 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
 
Hazardous live terminals, 
instructions for wiring   
No live terminal. 
 
 
Instructions for replacing lithium 
battery  
No lithium battery 
 
 
Explanation of marking of the 
manually operated mechanical 
switch (MOMS)   
No explanation required (indication in the form of 
illumination) 
 
5.4.2 
Instructions for permanently 
connected equipment   
If not completely switched OFF from 
the mains, info required 
The apparatus is not for permanent connection 
 
6 HAZARDOUS 
RADIATION 
 
 
No radiation 
6.1 
High voltage (kV).   
 
 
Focus voltage (kV)   
 
 
Amount of radiation   
 
6.2 
Non-ionizing radiation (laser 
radiation)  
 
6.2.1 
Opening of any cover by hand   
 
 
Mechanical interlocking device   
 
 
Accessible emission normal 
operation / classification   
 
 Labelling 
 
 
6.2.2 
Accessible emission fault condition 
outside / inside 
 
 
Warning label requirement   
 
 
HEATING UNDER NORMAL 
OPERATING CONDITIONS   
 
 
Power consumption in the 
OFF/Stand-by mode (ref. 14.6.2) 
Position of the functional switch (W) 
In OFF/Stand-by position, the power consumption is less 
than 15W. 
 
Surge current needed in clause 14.6 
when testing mains switches or 
functional switches conductively 
connected to the supply mains. 
(Note! Mains socket-outlet Clause 
14.6.10.) 
Ref. clause 14.6. 