Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 31 of 39 -
Order
No.
200245266
20.2.2
Internal fire enclosures with
openings not exceeding 1 mm in
width and with openings for wires
completely filled
openings not exceeding 1 mm in
width and with openings for wires
completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2
met by an internal fire enclosure
met by an internal fire enclosure
N
A
ANNEX A, ADDITIONAL
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
REQUIREMENTS FOR
APPARATUS WITH PROTECTION
AGAINST SPLASHING WATER
Not intended for outdoor use.
N
A.5.1
j) Marked with IPX4 (IEC 60 529),
5.4.1 a) does not apply
5.4.1 a) does not apply
N
A.10.2.1
Enclosure provides protection
against splashing water
against splashing water
N
A.10.2.2
Humidity treatment carried out for
7 days
7 days
N
B
ANNEX B, APPARATUS TO BE
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
CONNECTED TO THE
TELECOMMUNICATION
NETWORKS
Not intended for telecommunication networks
N
B.5.4.1
e) Where the separation of TNV
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
circuits from other circuits relies on
protective earthing the instructions
make it clear that protective earthing
is essential
N
B.8.1
TNV circuits separated from the
mains circuit and from hazardous
live parts by either:
mains circuit and from hazardous
live parts by either:
N
a) double or reinforced insulation
N
b) basic insulation with earthed
protective screening
protective screening
N
B.8.2
TNV circuits separated from circuits
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
other than those in B.8.1 and from
accessible conductive parts by basic
insulation meeting the requirements
for clearances and creepage
distances for the voltages concerned
N
B.9.1.1
TNV circuit terminals contacts which
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
cannot be touched by probe B.1,
exempt from the requirements
inaccessible terminal contacts in
9.1.1
N
-
IEC 60065, 6th edition : 1998
-
- Page 32 of 39 -
Order
No.
200245266
B.10.1
Insulation between TNV terminals
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
and antenna terminals (including
interconnection terminals which may
be connected to equipment with
antenna terminals) withstands the
50 discharges of 10.1
N
B.14.12
Surge suppressors between TNV
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
circuits and other parts of the
equipment have breakdown voltage
at least 1,8 times the mains voltage
N
-
IEC 60065, 6th edition : 1998
-
- Page 33 of 39 -
Order
No.
200245266
LIST OF CRITICAL COMPONENTS
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
Main
transformer
Bobbin Mtl.
Thermal fuse
Bobbin Mtl.
Thermal fuse
Seoul Electronics &
Telecom Co., Ltd.
Various
NEC SHOTT Comp.
Telecom Co., Ltd.
Various
NEC SHOTT Comp.
55589450NR
PBT
PBT
or equiv.
SF169E-1
230V, Class E
UL94V-0.
10A/250V,
UL94V-0.
10A/250V,
172C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL
VDE
UL
VDE
TP11 Sub
transformer
Bobbin Mtl.
Bobbin Mtl.
ORIENTECH Co., Ltd.
Various
Various
55643480NR
PETP
PETP
or equiv.
230V, Class E
UL94V-0
UL94V-0
IEC60065
clause 14.3
UL94
clause 14.3
UL94
1.)
UL
UL
NS22 A
ppliance inlet
I-SHENG
7014
10A / 250V~
IEC60320
VDE
Mains
plug
with cord
Not evaluated, ref.
Summary of testing
Summary of testing
Mains switch
Alps Electric
Co., Ltd.
Co., Ltd.
SDL1P-D
5A/80A 250V
IEC 61058
IEC 60065
IEC 60065
VDE
SK11 Mains
relay
Original
Electromech.
SDT-S-112DMR
8A/120A 250V
IEC61058-1
IEC 60065
IEC 60065
SEMKO
Mains
socket-
outlet
Dae Ryung Electronic
A3-04-D007
2.5A/250V
IEC 60884-1
NEMKO
F101 Mains
fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Samjoo Fuse Co. Ltd.
Schurter AG.
Littelfuse Triad Inc.
Sun Electric Co. Ltd.
Littelfuse Ltd.
Littlefuse B.V.
Schurter AG.
Littelfuse Triad Inc.
Sun Electric Co. Ltd.
Littelfuse Ltd.
Littlefuse B.V.
50T
FST
50T
5T
218 xxx
218 xxx
FST
50T
5T
218 xxx
218 xxx
T5A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F102 Mains
fuse
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Samjoo Fuse Co. Ltd.
Schurter AG.
Littelfuse Triad Inc.
Sun Electric Co. Ltd.
Littelfuse Ltd.
Littlefuse B.V.
Schurter AG.
Littelfuse Triad Inc.
Sun Electric Co. Ltd.
Littelfuse Ltd.
Littlefuse B.V.
50T
FST
50T
5T
218 xxx
218 xxx
FST
50T
5T
218 xxx
218 xxx
T3.15A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F501,F502
F503,F504
F503,F504
Sec. fuse
Save Fusetech Inc.
SS-5
T2A 250V
UL198
UL
F505,F506
Sec. fuse
Save Fusetech Inc.
SS-5
T1A 250V
UL198
UL
Brushless
DC Fan
DC Fan
X
INRUILIAN
E
lectronics
(Shenzhen) Co., Ltd.
RMD8025S 0.11A/12V
DC.
CFM: 26.97
EN60950 TUV
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 39 -
Order
No.
200245266
LIST OF CRITICAL COMPONENTS (continued)
P
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
CA11 X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
Ultra Tech Xiphi.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
Ultra Tech Xiphi.
PCX2 335M
PCX2 335
KNB1530
RE104
WBU1942
HQX
PCX2 335
KNB1530
RE104
WBU1942
HQX
0.10uF 275V
X2
X2
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
C118 X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Korea Electronics
Netron Tech.
Sam Wha Capacitor.
JYH CHUNG
Murata Mfg.
Dongguan South Hong-
ming
Netron Tech.
Sam Wha Capacitor.
JYH CHUNG
Murata Mfg.
Dongguan South Hong-
ming
Electronic Ceramic.
NU
AA
SC
JY
KH
F
AA
SC
JY
KH
F
0.0047uF/250V
X1/Y2
X1/Y2
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
PCB base mtl.
Various
Various
Min 94V-1
UL 796
UL
Comments
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998