DOWNLOAD Harman Kardon AVR 4550 Service Manual ↓ Size: 1.85 MB | Pages: 49 in PDF or view online for FREE

Model
AVR 4550
Pages
49
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-4550.pdf
Date

Harman Kardon AVR 4550 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 19 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.3.3-5 Transformer 
construction 
See below. 
14.3.3.2 
Transformers meet the 
constructional requirements : 
See below. 
Transformer/motor Insulation Insulation 
Test  Flashover 
Creepage 
distances 
Part No/markings 
between 
resistance 
voltage 
Breakdown 
and clearances 
 
 
  M Ohm 
kV(60)s 
voltage kV 
Measured 
Required  
55589450NR 
Pr - sec 
> 100 
3KV(rms) 
> 7,0 mm 
≥≥≥≥
 6 mm 
 
Pr - ic 
> 100 
3KV(rms) 
> 7,2 mm 
≥≥≥≥
 6 mm 
 
 
 
 
 
 
 
55643480NR 
Pr - sec 
> 100 
3KV(rms) 
> 6,6 mm 
≥≥≥≥
 6 mm 
 
Pr - ic 
> 100 
3KV(rms) 
> 6,2 mm 
≥≥≥≥
 6 mm 
 
 
 
 
 
 
 
 
Components / construction 
(Main transformer)
   
Windings on two separate bobbins. The bobbins are 
placed in an insulating housing with two compartments, 
one above the other. Bobbin thickness: > 0,4mm. 
 
Components / construction 
(Sub transformer)
   
Windings on single bobbins. A wall (2 layers) is provided 
between primary and secondary windings. Satisfactory 
constructed. Bobbin thickness: > 0,4mm. 
Transformer/mot
or 
Insulation 
Thickness (mm) 
Material 
Dielectric strength test 
Part 
No/markings 
between 
      X 
 
for each combination of 
 
 
    Number 
 
two (2) layers  
55589450NR 
Pr - sec 
0,80 mm min. x 1 
PBT bobbin 
Pass *) 
 
Pr - ic 
0,80 mm min. x 1 
PBT bobbin 
Pass *) 
 
 
 
 
 
55643480NR 
Pr - sec 
0,50 mm min. x 2 
PETP bobbin wall 
Pass    *) 
 
Pr - ic 
0,60 mm min. x 1 
66 Nylon bobbin cap. 
Pass    *) 
 
Pr - ic 
0,70 mm min. x 1 
PETP bobbin 
Pass    *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms. 
14.3.4.1 
Class II transformers have adequate 
separation between hazardous live 
windings and windings intended to 
be connected to accessible 
conductive parts (double or 
reinforced insulation)   
Double or reinforced insulation between primary and 
secondary windings according to clause 8.8. 
 
 
Coil formers and partition walls 
 0,4 mm   
The bobbin(s) fulfils the requirement of reinforced 
insulation, see table above for bobbin thickness. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 20 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.3.4.2 
Class I transformers, with basic 
insulation and protective screening 
only if all 7 conditions of 14.3.4.2 are 
met  
 
14.3.4.3 
Separating transformers with at least 
basic insulation   
 
14.3.5.1 
Class II transformers have adequate 
insulation between hazardous live 
parts and accessible parts (double or 
reinforced insulation)   
Double or reinforced insulation between hazardous live 
windings and accessible conductive parts. 
 
Coil formers and partition walls 
 0,4 mm   
The bobbin(s) fulfils the requirement of reinforced 
insulation, see table above for bobbin thickness. 
14.3.5.2 
Class I transformers have adequate 
insulation between hazardous live 
parts and accessible conductive 
parts or those conductive parts or 
protective screens connected to a 
protective earth terminal   
 
 
Winding wires connected to 
protective earth have adequate 
current-carrying capacity   
 
14.4 
High voltage components 
 
 
 
High-voltage components and 
assemblies: U > 4 kV (peak) 
separately approved   
No high voltage components used 
 
 
Component meets category FV 1 of 
IEC 60 707   
 
14.4.1 
High voltage transformers and 
multipliers tested as part of the 
submission  
 
14.5 Protective 
devices 
 
 
 
Protective devices used within their 
ratings  
Thermal link and fuses 
 
External clearance and creepage 
distances appropriate for the voltage 
across the device when opened   
 
14.5.1.1 
a) Thermal cut-outs separately 
approved  
None 
 
b) Thermal cut-outs tested as part of 
the submission   
 
14.5.1.2 
a) Thermal links separately 
approved  
Manuf.: NEC SHOTT Components Corporation. 
Type: SF169E-1 
Certified by: VDE 
According to IEC60691 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 21 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
 
b) Thermal links tested as part of the 
apparatus  
 
14.5.1.3 
Thermal devices resettable by 
soldering  
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit 
according to IEC 60 127   
See list below 
Circuit 
Manufacturer Dimen- 
Approved 
Marking 
of 
Marking Current 
diagram 
 
sions 
by 
rated current, 
close to 
through 
informa- 
 
 
 
pre-arcing time 
the com- 
the fuse   
tion 
 
 
 and 
current 
ponent in 
normal 
Part No 
 
 
 
characteristic 
 
operation 
F101 (pr.) 
S
amjoo 
F
use 
C
L
td.
 5 
××××
 20mm,   
VDE 
T5A L 250V 
T5A L 250V 
< 2,25 A 
F102 (pr.) 
S
amjoo 
F
use 
C
L
td.
 
5
××××
20mm,   
VDE 
T3.15A L 250V 
T3.15A L 250V 
< 0,70 A 
F501, F502 
SAVE FUSETECH INC. 
8,4 
××××
 8,4mm 
UL 
T2A 250V 
T2A L 250V 
< 0,66 A 
F503, F504 
SAVE FUSETECH INC. 
8,4 
××××
 8,4mm 
UL 
T2A 250V 
T2A L 250V 
< 1,01 A 
F505, F506 
SAVE FUSETECH INC. 
8,4 
××××
 8,4mm 
UL 
T1A 250V 
T1A L 250V 
< 0,10 A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.5.2.2 
Correct marking of fuse-links 
adjacent to holder      
Correct marking applied close to the fuse, see table 
above. 
14.5.2.3 
Not possible to connect fuses in 
parallel    
No fuse holder so designed that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous live 
parts when replacing fuse-links 
without the use of a tool     
No replacement of fuse possible by hand. 
 
14.5.3 
PTC-S thermistors comply with 
IEC 60 738   
No PTC’s 
 
PTC-S devices (>15 W) category 
FV 1 or better   
 
14.5.4 
Other protective devises. 
Circuit protectors have adequate 
breaking capacity and their position 
is correctly marked   
No other protective devices 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 39 - 
 
 
   
 Order 
No. 
200245266
 
 
 
 
14.6 Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
 
Part No 
Function 
Manufacturer 
Type 
Rated 
Marking 
 
All- 
One 
Name 
Trademark 
 
V A Surge 
 
pole 
pole 
 
 
 
  current
 
 
 
 
 
 
 
 
 
 
Alps Electric Co., Ltd. 
SDL1P-D 
250 
80A 
SK11 
 x 
Original 
Electromecha. 
OEG 
SDT-S-112DMR 250 
8 120A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
 
Exception for automatic switching   
 
 
Exception for continuous operation   
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
 
Indication by marking meets Cl. 5   
Yes 
 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
 
Stand-by mode clearly discernible    
LED indication 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes. See clause 14.2.2. 
 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1   
Yes.  
- Mains switch, certified by VDE, 
- Mains relay, certified by SEMKO. 
Page of 49