DOWNLOAD Harman Kardon AVR 355 (serv.man6) Service Manual ↓ Size: 1.76 MB | Pages: 58 in PDF or view online for FREE

Model
AVR 355 (serv.man6)
Pages
58
Size
1.76 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-355-sm6.pdf
Date

Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online

 
 
- Page 25 of 42 - 
 
 
 
 
Report No.  98388 
 
 
19 STABILITY 
AND 
MECHANICAL HAZARDS
 
 
Mass of the equipment exceeding 7 kg  .................. : 
Weight: 14,3 kg 
— 
 
Apparatus intended to be fastened in place – suitable 
instructions 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
Tested on a plane  inclined at 
angel of 10° 
19.2 
100 N force applied vertically downwards 
100N force have no influence  
on the stability 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability. 
< 25 kg and < 1 M 
N/A 
19.4 
Edges or corners not hazardous 
There are no hazardous edges 
or corners when the 
apparatus is operating in 
normal position. 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1 
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate 
No wall or ceiling mountings 
N/A 
 
 
 
 
20 
RESISTANCE TO FIRE
 
20.1 
Electrical components and mechanical parts 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 
60695-11-10
 with 
openings not exceeding 1 mm in width 
 
N/A 
 
b) Exemption for small components as defined in 20.1
PCB is of flammability class 
FV 0, and exception is  
made for small components 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
Electrical components 
comply with flammability 
requirements in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages > 4 Kv 
or leaving an internal fire enclosure,
 or located within 
the areas mentioned in Table 21,
 not contributing to 
the spread of fire 
No wires working at 
voltages> 4kV or leaving 
an internal fire enclosure 
N/A 
 
 
 
- Page 26 of 42 - 
 
 
 
 
Report No.  98388 
 
 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better 
to IEC60707, unless used in a fire enclosure 
All PCB are of base 
material with flammability 
category V-0 (UL approved) 
See list of critical  
components 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
No voltage exceeding 400V 
(peak) a.c. or d.c. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the distances 
in Table 21 comply with the relevant flammability 
category in Table 21 
No such components 
N/A 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
No such components 
N/A 
 
Apparatus with voltages >4kV under normal operating 
conditions and distances to the enclosure exceed 
those specified Table 21, flammability classification 
HB40 or better is required for the enclosure. 
Normal operating voltage 
< 4kV 
N/A 
20.2 Fire 
enclosure 
No fire enclosure 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure 
to V-1 
No voltages exceeding 4kV, 
no fire enclosure  
requirement 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires completely 
filled 
No internal fire enclosure 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an internal 
fire enclosure 
No internal fire enclosure 
N/A 
 
 
 
- Page 27 of 42 - 
 
 
 
 
Report No.  98388 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
Not intended for outdoor  
use. 
N/A 
A.10.2.1  Enclosure provides protection against splashing water
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
See clause above. 
N/A 
 
 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex B 
of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
IEC 62151 clause 4.1.1:  
Add after the first paragraph: 
 
NOTE-
In Finland, Norway and Sweden, class I equipment  
which is intended for connection to the building  
installation via a non-industrial plug or a non-industrial 
appliance coupler or both and in addition is intended  
for connection to other equipment or a network shall, 
if safety relies on connection to protective earth or if  
surge suppressors are connected between the  
network terminals and ACCESSIBLE parts, have a  
marking stating that the equipment must be connected
 to an earthed mains socket-outlet. 
 
The marking text in the applicable countries shall 
be as follow: 
 
In Finland;  
”Laite on liitettävä suojamaadoituskoskettimilla 
va rustettuumpistorasiaan” 
 
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt” 
 
In Sweden; ”Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
N/A 
 
 
 
- Page 28 of 42 - 
 
 
 
 
Report No.  98388 
 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES. 
 
L5.4 
Marking and Instructions 
 
N/A 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in Table  
3 , unless comply with 6.3.2 of IEC 60086-4 
 
N/A 
L14.6.6 
Mains switch characteristics   appropriate to its 
function under normal conditions 
 
N/A 
 
Page of 58