Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online
- Page 25 of 42 -
Report No. 98388
19 STABILITY
AND
MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg .................. :
Weight: 14,3 kg
—
Apparatus intended to be fastened in place – suitable
instructions
instructions
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested on a plane inclined at
angel of 10°
angel of 10°
P
19.2
100 N force applied vertically downwards
100N force have no influence
on the stability
on the stability
P
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability.
point of least stability.
< 25 kg and < 1 M
N/A
19.4
Edges or corners not hazardous
There are no hazardous edges
or corners when the
apparatus is operating in
normal position.
or corners when the
apparatus is operating in
normal position.
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
No glass surface
N/A
19.6
Wall or ceiling mountings adequate
No wall or ceiling mountings
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC
enclosure of material V-0 to IEC
60695-11-10
with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in 20.1
PCB is of flammability class
FV 0, and exception is
made for small components
FV 0, and exception is
made for small components
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components
comply with flammability
requirements in clause 14.
comply with flammability
requirements in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages > 4 Kv
or leaving an internal fire enclosure,
or leaving an internal fire enclosure,
or located within
the areas mentioned in Table 21,
not contributing to
the spread of fire
No wires working at
voltages> 4kV or leaving
an internal fire enclosure
voltages> 4kV or leaving
an internal fire enclosure
N/A
- Page 26 of 42 -
Report No. 98388
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC60707, unless used in a fire enclosure
All PCB are of base
material with flammability
category V-0 (UL approved)
See list of critical
components
material with flammability
category V-0 (UL approved)
See list of critical
components
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N/A
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
No such components
N/A
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal operating
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
Normal operating voltage
< 4kV
< 4kV
N/A
20.2 Fire
enclosure
No fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure
to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure
to V-1
No voltages exceeding 4kV,
no fire enclosure
requirement
no fire enclosure
requirement
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires completely
filled
1 mm in width and with openings for wires completely
filled
No internal fire enclosure
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an internal
fire enclosure
fire enclosure
No internal fire enclosure
N/A
- Page 27 of 42 -
Report No. 98388
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor
use.
use.
N/A
A.10.2.1 Enclosure provides protection against splashing water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
See clause above.
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex B
of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex B
of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
IEC 62151 clause 4.1.1:
Add after the first paragraph:
Add after the first paragraph:
NOTE-
In Finland, Norway and Sweden, class I equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have a
marking stating that the equipment must be connected
to an earthed mains socket-outlet.
In Finland, Norway and Sweden, class I equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have a
marking stating that the equipment must be connected
to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
be as follow:
In Finland;
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
In Sweden; ”Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
- Page 28 of 42 -
Report No. 98388
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.3.2 of IEC 60086-4
3 , unless comply with 6.3.2 of IEC 60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A