Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online
- Page 5 of 42 -
Report No. 98388
Test item particulars .................................................. :
A/V Surround Receiver
Classification of installation and use ...................... :
Class II
Supply connection .................................................... :
Detachable
...................................................................................... :
See Summary of testing for details
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ........... :
N/A
- test object does meet the requirement .................. :
Pass (P)
- test object does not meet the requirement ........... :
Fail (F)
Testing:
Date of receipt of test items ..…….………………….:
December 12, 2007
Date(s) of performance of tests ................................ :
December 12, 2007 - January 22, 2008
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The sample(s) tested complies with the requirements of IEC 60065: 2001 + Amd 1: 2005 /
EN 60065: 2002 + A1: 2006. Compliance with European Special National Conditions, Annex ZB, and
A – Deviations, Annex ZC and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065:2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
EN 60065: 2002 + A1: 2006. Compliance with European Special National Conditions, Annex ZB, and
A – Deviations, Annex ZC and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065:2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
- Page 6 of 42 -
Report No. 98388
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test box
No test box required.
Tested according to
manufactures instructions.
Tested according to
manufactures instructions.
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit.
P
5.1 Identification,
maker, model .................................... :
Brand: Harman Kardon
Model: AVR 355/230
See copy of marking plate.
Model: AVR 355/230
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol ........................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60Hz” or “60Hz”
P
Rated current or power consumption ..................... :
400W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
40Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
The output signal will rise to
40Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
P
Supply output terminals (other than mains)
“W’ and “A” with rated supply
voltage/frequency marked
closed to the socket-outlet;
voltage/frequency marked
closed to the socket-outlet;
SWITCHED (50W, 0.5A MAX)
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
printed on rear side in connectio
n with CAUTION of
opening. Further; no incorrect us
e of this symbol is found.
printed on rear side in connectio
n with CAUTION of
opening. Further; no incorrect us
e of this symbol is found.
P
- Page 7 of 42 -
Report No. 98388
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
Mains powered equipment not exposed to dripping or
splashing. Warning concerning objects filled with
liquid, etc.
splashing. Warning concerning objects filled with
liquid, etc.
The user manual includes
information about danger
concerning dripping or
splashing and objects filled
with liquids.
information about danger
concerning dripping or
splashing and objects filled
with liquids.
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
Instructions for replacing lithium battery
No lithium battery in the
equipment.
equipment.
N/A
Instructions for modem if fitted
No modem.
N/A
Class I earth connection warning
Class II apparatus.
N/A
Instructions for multimedia system connection
Not applicable
N/A
Special stability warning for fixed installation
Not for fixed installation.
N/A
Warning: battery exposure to heat
No battery
N/A
Warning: protective film on CRT face
No CRT
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Appliance coupler defined as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected equipment
Not permanently connected
equipment.
equipment.
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No lionizing radiation
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13 May
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
1996 10cm from outer surface of apparatus <1µSv/h
(0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ..... :
No laser radiation
N/A
Emission limits under fault conditions ..................... :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values, no
operation of fuse links
operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
- Page 8 of 42 -
Report No. 98388
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible.
not possible.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by
hand.
hand.
N/A
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus have
isolating transformers
isolating transformers
P