Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online
- Page 17 of 42 -
Report No. 98388
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the
requirement of reinforced
insulation;
bobbin thickness > 0.4 mm
requirement of reinforced
insulation;
bobbin thickness > 0.4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer provided.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Approved fuses and thermal
links.
links.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Adequate external clearance
and creepage distance.
and creepage distance.
P
14.5.1.1
a) Thermal cut-outs separately approved
None.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal links in main and
sub transformer are separately
approved component.
See list of critical components.
sub transformer are separately
approved component.
See list of critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable by soldering.
re-settable by soldering.
P
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127
Fuses are approved
components according to
IEC 60127.
See list critical components.
components according to
IEC 60127.
See list critical components.
P
- Page 18 of 42 -
Report No. 98388
14.5.2.2
Correct marking of fuse-links adjacent to holder .... :
The following marking applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T2.5A L 250V
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T2.5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ :
No possible to connect
fuses in parallel.
fuses in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N/A
PTC-S devices (15 W) category V-1 or better
None
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No other protective devices.
N/A
14.6 Switches
P
14.6.1 a) Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Yes,
Mains switch and relay
provided. Certified according
to IEC61058-1.
- Mains switch, certified by
FIMKO
- Mains relay certified by
SEMKO
See list of critical components.
Mains switch and relay
provided. Certified according
to IEC61058-1.
- Mains switch, certified by
FIMKO
- Mains relay certified by
SEMKO
See list of critical components.
P
14.6.1 b) Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
subclause 13.1 and has making/breaking action
independent of speed of actuation
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N/A
- Page 19 of 42 -
Report No. 98388
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay =
= 37A + 20 A *
*) Added current for socket
outlet marked “0.5 A”.
The measured inrush current
value is less than rated inrush
current rating of the mains
relay (120A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay =
= 37A + 20 A *
*) Added current for socket
outlet marked “0.5 A”.
The measured inrush current
value is less than rated inrush
current rating of the mains
relay (120A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
P
Socket outlet current marking correct
Socket outlet marking:
SWITCHED (50W, 0.5A MAX)
SWITCHED (50W, 0.5A MAX)
N/A
14.7 Safety
interlocks
No safety interlock
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage selector
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
DC brush-less fan motor
P
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
Only DC supplied
N/A
14.9.2
Not adversely affected by oil or grease etc.
The fans are not adversely
affected by oil, grease or
other substances.
affected by oil, grease or
other substances.
P
14.9.3
Protection against moving parts
The fan is placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
- Page 20 of 42 -
Report No. 98388
14.10 Batteries
No batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Approved appliance inlet
coupler and main socket-outlet
provided, See list of critical
components.
coupler and main socket-outlet
provided, See list of critical
components.
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
Prevented by the fuse;
F902 (T2.5A L 50V)
F902 (T2.5A L 50V)
P
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
Prevented by the fuse;
F902 (T2.5A L 50V)
F902 (T2.5A L 50V)
P
Click on the first or last page to see other AVR 355 (serv.man6) service manuals if exist.