Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online
- Page 9 of 42 -
Report No. 98388
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors.
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
No such capacitors.
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components.
N/A
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced
insulation > 0,4 mm (mm) .................... :
Bobbin of main and sub
transformer.
See appended table and
attachment, Table to
EN/IEC 60065 7
transformer.
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
No thin sheet insulation
N/A
Basic or supplementary insulation, at least two layers,
each meeting 10.3
each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulation but safely
anchored
anchored
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double insulated, tested
according to 8.9 and 10.3.
according to 8.9 and 10.3.
P
- Page 10 of 42 -
Report No. 98388
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
One end of inlet and switch
connected wires are hooked-
in before soldered.
Other ends of inlet and switch
connected wires are
connected with multi-contact
housing.
connected wires are hooked-
in before soldered.
Other ends of inlet and switch
connected wires are
connected with multi-contact
housing.
P
Vibration
test carried out ......................................... :
See 12.1.2
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for 10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temperature and sharp edges
away from parts with high
temperature and sharp edges
P
8.16
Only special supply equipment can be used
No supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such components.
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below
P
8.19.1 Disconnect
device
Appliance coupler is
disconnection device
disconnection device
P
All-pole switch or circuit breaker with >3mm contact se
paration
paration
No all-pole switch and circuit
breaker.
breaker.
N/A
8.19.2
Mains switch ON indication
Indicator lamp or FL display
lit-on for mains switch ON
indication, but switch is single
pole only.
lit-on for mains switch ON
indication, but switch is single
pole only.
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
Yes, relay across the capacitor
is certified component.
See appended table, list of
critical components.
is certified component.
See appended table, list of
critical components.
P
8.22
Non-separable thin sheet material
No non-separable thin
sheet material.
sheet material.
N/A
- Page 11 of 42 -
Report No. 98388
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000V ac or 1500V dc
1000V ac or 1500V dc
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage >35V
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
Edition.
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored
voltages between 60V-15kV
terminal with stored
voltages between 60V-15kV
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of
a terminal with stored
Voltages exceeding 15kV.
a terminal with stored
Voltages exceeding 15kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts.
live parts.
P
9.1.2
No hazardous live shafts of knobs, handles or levers
No live shaft handles or
levers.
levers.
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test pin
(10 N); test probe C of IEC 61032
(10 N); test probe C of IEC 61032
No preset controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ................... :
of the mains plug; voltage (V) after 2 s ................... :
See below
N/A
If C is not greater than 0,1 μF no test needed
< 0,1uF
N/A
9.1.7
a) Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard.
in no hazard.
P
- Page 12 of 42 -
Report No. 98388
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook result
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N result
in no damage.
in no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by
hand.
hand.
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
> 100MΩ, after surge test
P
10.2 Humidity
treatment 48 h or 120 h ........................... :
Performed for 120h at
temp. 40°C and relative
humidity 93%.
temp. 40°C and relative
humidity 93%.
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
See appended table
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus.
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
No hazard from softening solder
No softening of solder.
P
Flames extinguish within 10 seconds
No flames.
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations.
P
11.2.1
Measurement of temperature rises
See appended table.
P
11.2.2
Temperature rise of accessible parts
See appended table.
P