- Page 9 of 42 - 
 
 
 
 
Report No.  98388 
 
 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) 
No such capacitors. 
N/A 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
No such capacitors. 
N/A 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
No such capacitors. 
N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components. 
N/A 
8.7 
This clause is void 
 
— 
8.8 
Basic or supplementary insulation > 0,4 mm (mm)  : 
 
N/A 
 Reinforced 
insulation > 0,4 mm (mm)  .................... : 
Bobbin of main and sub  
transformer. 
See appended table and 
attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
No thin sheet insulation 
N/A 
 
Basic or supplementary insulation, at least two layers, 
each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 
N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts 
Double insulated 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
Single insulation but safely 
anchored 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
Double insulation between internal  hazardous live 
parts and conductors connected to accessible parts. 
Double insulated, tested  
according to 8.9 and 10.3. 
 
 
 
- Page 10 of 42 - 
 
 
 
 
Report No.  98388 
 
 
8.11 
Detaching of wires 
 
 
No undue reduction of creepages or clearance  
distances if wires become detached 
One end of inlet and switch 
connected wires are hooked- 
in before soldered. 
Other ends of inlet and switch 
connected wires are  
connected with multi-contact 
housing. 
 Vibration 
test carried out  ......................................... : 
See 12.1.2 
8.12 
This clause is void 
 
— 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
Adequately fastened. 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s) 
Covers adequately fastened 
with screws. 
8.15 
No risk of damage to the insulation of internal wiring  
due to hot parts or sharp edges 
Wires safely anchored 
away from parts with high 
temperature and sharp edges 
8.16 
Only special supply equipment can be used 
No supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
No such components. 
N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
Appliance coupler is  
disconnection device 
 
All-pole switch or circuit breaker with >3mm contact se
paration 
No all-pole switch and circuit 
breaker. 
N/A 
8.19.2 
Mains switch ON indication 
Indicator lamp or FL display 
lit-on for mains switch ON  
indication, but switch is single 
pole only. 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
Yes, relay across the capacitor 
is certified component. 
See appended table, list of  
critical components. 
8.22 
Non-separable thin sheet material 
No non-separable thin  
sheet material. 
N/A 
 
 
 
- Page 11 of 42 - 
 
 
 
 
Report No.  98388 
 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltages exceeding  
1000V ac or 1500V dc 
N/A 
9.1.1.1 
a) Open circuit voltages 
Mains input voltage >35V 
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
See attachment, Table to 
EN/IEC 60065 7
th
 Edition. 
 
c) Discharge not exceeding 45 μC 
No part or contact of a 
terminal with stored  
voltages between 60V-15kV 
N/A 
 
d) Energy of discharge not exceeding 350 mJ 
No part or contact of 
a terminal with stored 
Voltages exceeding 15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe 
No access to hazardous 
live parts. 
9.1.2 
No hazardous live shafts of knobs, handles or levers 
No live shaft handles or 
levers. 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin 
No access for the test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts. 
 
Terminal devices tested with 1 mm x 100 mm straight 
wire (1 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts. 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test pin 
(10 N); test probe C of IEC 61032 
No preset controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  ................... : 
See below 
N/A 
 
If C is not greater than 0,1 μF no test needed 
< 0,1uF 
N/A 
9.1.7 
a) Enclosure sufficiently resistant to external force 
 
 
 Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger result 
in no hazard. 
 
 
 
- Page 12 of 42 - 
 
 
 
 
Report No.  98388 
 
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook result 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  : 
Tested with 100N result 
in no damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by 
hand. 
N/A 
 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
> 100MΩ, after surge test 
10.2 Humidity 
treatment 48 h or 120 h  ........................... : 
Performed for 120h at  
temp. 40°C and relative  
humidity 93%. 
10.3 
Insulation resistance and dielectric strength between 
mains teminals 
See appended table 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
Class II apparatus. 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
See appended table 
 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
No electric shock hazard 
under fault conditions. 
11.2 
Heating under fault condition 
See attachment, Tables to 
EN/IEC 60065 7
th
 edition. 
 
No hazard from softening solder 
No softening of solder. 
 
Flames extinguish within 10 seconds 
No flames. 
 
Soldered terminations not used  as protective 
mechanism 
No soldered terminations. 
11.2.1 
Measurement of temperature rises 
See appended table. 
11.2.2 
Temperature rise of accessible parts 
See appended table. 
 