DOWNLOAD Harman Kardon AVR 355 (serv.man6) Service Manual ↓ Size: 1.76 MB | Pages: 58 in PDF or view online for FREE

Model
AVR 355 (serv.man6)
Pages
58
Size
1.76 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-355-sm6.pdf
Date

Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate ▷ View online

 
 
- Page 29 of 42 - 
 
 
 
 
Report No.  98388 
 
 
7.1 
TABLE: temperature rise measurements 
 
 
Power consumption in the OFF/Stand-by 
In OFF/Stand-by position, 
the power consumption is  
less than 4,0W 
 
Position of the functional switch (W)  ...................... :  
— 
Operating conditions 
Standby mode at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 0,015  2,3  — 
220 0,018  2,8  — 
230 0,020  3,1  — 
253 0,028  4,0  — 
Standby mode at 60Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 0,013  2,2  — 
220 0,015  2,6  — 
230 0,015  2,8  — 
242 0,016  3,1  — 
253 0,018  3,4  — 
 
Measured at maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
5,26 
1104 
F) 
2 x 82,4 
SB)  2 x 81,1 
C) 
1 x 85,2 
S) 
2 x 89,8 
Measured at maximum non-clipped output at 60Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
5,19 
1091 
F) 
2 x 82,4 
SB)  2 x 81,1 
C) 
1 x 85,2 
S) 
2 x 89,8 
Tested condition; 1kHz input signal, connected 8 ohm loads for F, SB, C, S channels 
 
 
- Page 30 of 42 - 
 
 
 
 
Report No.  98388 
 
 
Measured at 1/8 of maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
198 
2,33 
#) 2,16 
361 
#) 332 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
220 
2,41 
#) 2,25 
412 
#) 383 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
230 
2,45 
#) 2,30 
435 
#) 407 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
253 
2,54 
#) 2,40 
494 
#) 469 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
Measured at 1/8 of maximum non-clipped output at 60Hz; 
198 
2,31 
#) 2,12 
359 
#) 329 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
220 
2,40 
#) 2,20 
409 
#) 375 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
230 
2,43 
#) 2,25 
431 
#) 399 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
242 
2,48 
#) 2,31 
463 
#) 432 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
253 
2,51 
#) 2,36 
488 
#) 459 
F) 
2 x 10,3 
SB)  2 x 10,1 
C) 
1 x 10,7 
S) 
2 x 11,2 
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected condition, and 
then replaced the input signal to pink noise for heating and fault condition tests. 
The values followed #) in table above are measured “A” or “W” values, when replaced the input signal from 
1 kHz sign wave to pink noise 
 
 
- Page 31 of 42 - 
 
 
 
 
Report No.  98388 
 
 
 
Loudspeaker impedance (Ω) …………:
8 Ohms 
— 
 
Several loudspeaker systems 
Right and Left for Front, 
Right and Left for Surround Back / Zone 2, 
Right and Left for Surround, 
Only one for Center. 
 
Marking of loudspeaker terminals 
SPEAKERS (8Ω): 
FRONT-R, FRONT-L,  
SBR/ ZONE 2 RIGHT, SBL/ZONE 2 LEFT 
SURR-R, SURR-L /, CENTER. 
 
 
 
 
- Page 32 of 42 - 
 
 
 
 
Report No.  98388 
 
Monitored point: 
dT (K) 
198V 50Hz
dT (K) 
253V 50Hz
dT (K) 
198V 60Hz 
dT (K) 
253V 60Hz 
Limit dT (K)
 *) 
E Capacitor, C916 body 
27,4 
39,4 
27,9 
39,6 
85
°C
 
E Capacitor, C909 body 
29,5 
39,2 
30,3 
39,2 
85
°C
 
Sub 
transformer 
core 
34,6 53,9 34,6 48,3 85 
PCB 
near 
Q805 
40,8 60,4 41,0 60,5 95 
TR, 
Q805 
body 
53,3 81,1 53,6 82,1 - 
FAN body (Internal main heat-sink center) 
31,1 
44,0 
31,6 
43,9 
FAN body (Internal main heat-sink side) 
15,5 
20,8 
16,1 
20,8 
E Capacitor, C941 body 
17,7 
24,9 
18,4 
24,9 
85
°C
 
Main 
heat-sink 
43,2 64,5 43,6 65,3 - 
E Capacitor, C129 body 
10,1 
11,6 
11,1 
11,5 
85
°C
 
PCB 
near 
D992 
68,4 80,3 68,7 81,4 95 
D992 
heat-sink 
70,0 81,8 70,2 83,2 - 
PCB 
near 
D991 
60,3 75,5 60,5 75,8 95 
D991 
heat-sink 
79,3 93,5 79,3 93,8 - 
In-let 
body 
21,7 28,8 22,5 28,8 50 
Main 
transformer 
core 
45,1 60,4 45,0 58,2 95 
Main switch button (located on rear 
panel) 
15,2 19,5 15,9 20,1 - 
Stand 
by 
switch 
button 
2,1 2,8 2,1 3,3 50 
Top enclosure above main transformer 
17,6 
23,7 
14,3 
23,3 
40 
Top enclosure above main heat-sink 
17,1 
24,4 
17,1 
28,5 
40 
Front panel (metallic decorative part) 
10,0 15,2 11,7 16,2 40 
 
 
 
 
 
 
*) Temperature rise limits for Singapore is 10K less. 
 
Winding temperature rise  
measurements 
198V50Hz 253V50Hz 198V60Hz 253V60Hz 
 
 
Ambient temperature t1 (
o
C) : 
24,4 
24,4 
24,4 
24,4 
— 
 
Ambient temperature t2 (
o
C) : 
24,0 
24,0 
24,3 
23,0 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)
 *) 
Insulation 
class 
Main trans. Pri. winding (at 1/8Pmax), 198V 50Hz 
1,810 
2,220 
59,1 
95 
Sub trans. Pri. winding (at 1/8Pmax), 198V 50Hz 
1230 
1400 
36,2 
85 
Main trans. Pri. winding (at 1/8Pmax), 253V 50Hz 
1,810 
2,351 
77,8 
95 
Sub trans. Pri. winding (at 1/8Pmax), 253V 50Hz 
1230 
1513 
60,0 
85 
Main trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1,810 
2,231 
60,3 
95 
Sub trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1230 
1406 
37,1 
85 
Main trans. Pri. winding (at 1/8Pmax), 253V 60Hz 
1,810 
2,338 
76,9 
95 
Sub trans. Pri. winding (at 1/8Pmax), 253V 60Hz 
1230 
1471 
52,1 
85 
*) Temperature rise limits for Singapore is 10K less. 
 
Page of 58