Harman Kardon AVR 340 (serv.man12) EMC - CB Certificate ▷ View online
- Page 3 of 8 -
www.nemko.com
Report No. 65681
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse (A)
fuse (A)
Mains power/temperatures/results
C119
S - c
253
-
15min
F907
2,46
FL display off immediately.
Input current stabilised at 2,25A.
R101 opened.
D101, D102, Q104 damaged.
No hazard.
Input current stabilised at 2,25A.
R101 opened.
D101, D102, Q104 damaged.
No hazard.
C117
S - c
253
-
20min
F907
2,25
Normal operated.
Input current stabilised at 2,25A.
No component damaged.
No hazard.
Input current stabilised at 2,25A.
No component damaged.
No hazard.
C951
S - c
253
-
10min
F907
2,24
Normal operated.
Input current stabilised at 2,24A.
R950 opened.
No hazard.
Input current stabilised at 2,24A.
R950 opened.
No hazard.
Q803
S - c
253
C - E
10min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,02A.
F905, F906 opened.
Q804 damaged.
No hazard.
Input current stabilised at 0,02A.
F905, F906 opened.
Q804 damaged.
No hazard.
Q803
S - c
253
C - B
10min
F907
F905
F906
F905
F906
3,04
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C607
S - c
253
-
30min
F907
F905
F906
F905
F906
2,64
Surr. L ch. output voltage dropped
to 2,3V ac immediately.
Input current stabilised at 2,07A.
R821 opened.
No hazard.
to 2,3V ac immediately.
Input current stabilised at 2,07A.
R821 opened.
No hazard.
Q804
S - c
253
C - E
10min
F907
F905
F906
F905
F906
8,21
Unit shut down immediately.
Input current stabilised at 0,02A.
F905, F906 opened.
Q803 damaged.
No hazard.
Input current stabilised at 0,02A.
F905, F906 opened.
Q803 damaged.
No hazard.
Q804
S - c
253
C - B
10min
F907
F905
F906
F905
F906
2,94
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard
Input current stabilised at 0,02A.
No component damaged.
No hazard
C813
S - c
253
-
10min
F907
F905
F906
F905
F906
2,20
Surr. L ch output off immediately.
Input current stabilised at 1,99A.
No component damaged.
No hazard.
Input current stabilised at 1,99A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 4 of 8 -
www.nemko.com
Report No. 65681
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse (A)
fuse (A)
Mains power/temperatures/results
Q659
S - c
253
C - E
10min
F907
F903
F904
F903
F904
-
Unit shut down immediately.
Input current stabilised at 0,02A.
R658, F903, F904 opened.
Q653 damaged.
No hazard.
(Repeated test three times with the
same result)
Input current stabilised at 0,02A.
R658, F903, F904 opened.
Q653 damaged.
No hazard.
(Repeated test three times with the
same result)
Q659
S - c
253
C - B
10min
F907
F903
F904
F903
F904
2,98
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C633
S - c
253
-
10min
F907
F903
F904
F903
F904
2,59
Front L ch. output voltage dropped
to 2,4V ac immediately.
Input current stabilised at 2,06A.
R633 opened.
No hazard.
to 2,4V ac immediately.
Input current stabilised at 2,06A.
R633 opened.
No hazard.
Q653
S - c
253
C - E
10min
F907
F903
F904
F903
F904
-
Unit shut down immediately.
Input current stabilised at 0,02A.
F903, F904 opened.
Q659 damaged.
No hazard.
(Repeated test three times with the
same result)
Input current stabilised at 0,02A.
F903, F904 opened.
Q659 damaged.
No hazard.
(Repeated test three times with the
same result)
Q653
S - c
253
C - B
10min
F907
F903
F904
F903
F904
2,45
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C568
S - c
253
-
15min
F907
F903
F904
F903
F904
2,10
Front L ch output off immediately.
Input current stabilised at 2,02A.
No component damaged.
No hazard.
Input current stabilised at 2,02A.
No component damaged.
No hazard.
C902
S - c
253
-
10min
F907
F905
F906
F905
F906
6,40
Surround and Center output off
immediately.
Input current stabilised at 1,49A.
F905, F906 opened.
No hazard.
immediately.
Input current stabilised at 1,49A.
F905, F906 opened.
No hazard.
C902
S - c
207
-
10min
F907
F905
F906
F905
F906
6,10
Surround and Center output off
immediately.
Input current stabilised at 1,40A.
F905, F906 opened.
No hazard.
immediately.
Input current stabilised at 1,40A.
F905, F906 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 5 of 8 -
www.nemko.com
Report No. 65681
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse (A)
fuse (A)
Mains power/temperatures/results
C915
S - c
253
-
10min
F907
F903
F904
F903
F904
3,90
Front and S/B Multi output off
immediately.
Input current stabilised at 1,17A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
immediately.
Input current stabilised at 1,17A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
C915
S - c
207
-
10min
F907
F903
F904
F903
F904
-
Front and S/B Multi output off
immediately.
Input current stabilised at 1,10A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
immediately.
Input current stabilised at 1,10A.
F903, F904 opened.
No hazard.
(Repeated test three times with the
same result)
IC94
S - c
253
Pin 1 - 2 10min
F907
2,23
Normal operated.
Input current stabilised at 2,23A.
R950, R948 opened.
No hazard.
Input current stabilised at 2,23A.
R950, R948 opened.
No hazard.
IC94
S - c
253
Pin 1 - 3 10min
F907
2,31
Normal operated.
Input current stabilised at 2,31A.
No component damaged.
No hazard.
Input current stabilised at 2,31A.
No component damaged.
No hazard.
D962
S - c
253
-
7min
24sec
24sec
F907
2,30
Sub transformer primary winding he
ated up to 103.8K and thermal fuse
open after 7min 24sec.
Dielectric strength test ok.
No hazard.
ated up to 103.8K and thermal fuse
open after 7min 24sec.
Dielectric strength test ok.
No hazard.
C906
S - c
253
-
5min
8sec
8sec
F907
0,08
Unit shut down immediately.
Sub transformer primary winding
heated up to 101.9K and thermal fu
se open after 5min 8sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding
heated up to 101.9K and thermal fu
se open after 5min 8sec.
Dielectric strength test ok.
No hazard.
C911
S - c
253
-
7min
6sec
6sec
F907
0,08
Unit shut down immediately.
Sub transformer primary winding he
ated up to 102,8K and thermal fuse
open after 7min 6sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding he
ated up to 102,8K and thermal fuse
open after 7min 6sec.
Dielectric strength test ok.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- Page 6 of 8 -
www.nemko.com
Report No. 65681
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse (A)
fuse (A)
Mains power/temperatures/results
C907
S - c
253
-
19min
50sec
50sec
F907
0,05
Unit shut down immediately.
Sub transformer primary winding he
ated up to 101,3K and thermal fuse
open after 19min 50sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding he
ated up to 101,3K and thermal fuse
open after 19min 50sec.
Dielectric strength test ok.
No hazard.
FAN
(built-in
rear
panel)
(built-in
rear
panel)
Locked 253
-
3hr
F907
2,24
Normal
operated.
The components are heated up to :
-Main transf. pr. Winging :82,4K
-Main transformer core
-Main transf. pr. Winging :82,4K
-Main transformer core
:68,1K
-Sub transf. pr. Winging :61,0K
-Sub transformer core
-Sub transformer core
:57,9K
-PWB near Q803
:60,0K
-PWB near D991
:88,3K
and stabilised.
Dielectric strength test ok.
No hazard.
Dielectric strength test ok.
No hazard.
FAN
(built-in
main
(built-in
main
heat-sink
)
Locked 253
-
2hr
45min
45min
F907 2,24 Normal
operated.
The components are heated up to :
-Main transf. pr. Winging :72,6K
-Main transformer core
-Main transf. pr. Winging :72,6K
-Main transformer core
:48,1K
-Sub transf. pr. Winging :46,0K
-Sub transformer core
-Sub transformer core
:39,6K
-PWB near Q803
:53,3K
-PWB near D991
:66,5K
and stabilised.
Dielectric strength test ok.
No hazard.
Dielectric strength test ok.
No hazard.
Top
cover
opening
cover
opening
Block 253 -
18min
55sec
55sec
F907
2,24
Unit shut down after 18min 55sec.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Speaker
terminal
terminal
S – c
253
-
10min
F907
-
Unit shut down immediately.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Pmax
operating
operating
Maximun
non-
clipped o
utput sig
nal
non-
clipped o
utput sig
nal
253 -
1hr
40min
40min
F907
4,97
Front and S/B Mult output signal off
after 18min.
Rear and Center output signal off
after 1hr 25min.
Input current stabilised at 0,31A.
F903, F904, F905, F906 opened.
No hazard.
after 18min.
Rear and Center output signal off
after 1hr 25min.
Input current stabilised at 0,31A.
F903, F904, F905, F906 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection