Harman Kardon AVR 340 (serv.man12) EMC - CB Certificate ▷ View online

 
 
- Page 3 of 8 - 
 
 
www.nemko.com
 
Report No.  65681 
 
 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse (A)
Mains power/temperatures/results 
C119 
S - c 
253 
15min 
F907 
2,46 
FL display off immediately. 
Input current stabilised at 2,25A. 
R101 opened. 
D101, D102, Q104 damaged. 
No hazard. 
C117 
S - c 
253 
20min 
F907 
2,25 
Normal operated. 
Input current stabilised at 2,25A. 
No component damaged.  
No hazard. 
C951 
S - c 
253 
10min 
F907 
2,24 
Normal operated. 
Input current stabilised at 2,24A. 
R950 opened. 
No hazard. 
Q803 
S - c 
253 
C - E 
10min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
F905, F906 opened. 
Q804 damaged. 
No hazard. 
Q803 
S - c 
253 
C - B 
10min 
F907 
F905 
F906 
3,04 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C607 
S - c 
253 
30min 
F907 
F905 
F906 
2,64 
Surr. L ch. output voltage dropped 
to 2,3V ac immediately. 
Input current stabilised at 2,07A. 
R821 opened. 
No hazard. 
Q804 
S - c 
253 
C - E 
10min 
F907 
F905 
F906 
8,21 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
F905, F906 opened.  
Q803 damaged. 
No hazard. 
Q804 
S - c 
253 
C - B 
10min 
F907 
F905 
F906 
2,94 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard 
C813 
S - c 
253 
10min 
F907 
F905 
F906 
2,20 
Surr. L ch output off immediately. 
Input current stabilised at 1,99A. 
No component damaged. 
No hazard.  
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 
- Page 4 of 8 - 
 
 
www.nemko.com
 
Report No.  65681 
 
 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse (A)
Mains power/temperatures/results 
Q659 
S - c 
253 
C - E 
10min 
F907 
F903 
F904 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
R658, F903, F904 opened. 
Q653 damaged. 
No hazard. 
(Repeated test three times with the 
same result) 
Q659 
S - c 
253 
C - B 
10min 
F907 
F903 
F904 
2,98 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C633 
S - c 
253 
10min 
F907 
F903 
F904 
2,59 
Front L ch. output voltage dropped 
to 2,4V ac immediately. 
Input current stabilised at 2,06A. 
R633 opened. 
No hazard. 
Q653 
S - c 
253 
C - E 
10min 
F907 
F903 
F904 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
F903, F904 opened. 
Q659 damaged. 
No hazard. 
(Repeated test three times with the 
same result) 
Q653 
S - c 
253 
C - B 
10min 
F907 
F903 
F904 
2,45 
Unit shut down immediately. 
Input current stabilised at 0,02A. 
No component damaged. 
No hazard. 
C568 
S - c 
253 
15min 
F907 
F903 
F904 
2,10 
Front L ch output off immediately. 
Input current stabilised at 2,02A. 
No component damaged. 
No hazard. 
C902 
S - c 
253 
10min 
F907 
F905 
F906 
6,40 
Surround and Center output off 
immediately. 
Input current stabilised at 1,49A. 
F905, F906 opened. 
No hazard. 
C902 
S - c 
207 
10min 
F907 
F905 
F906 
6,10 
Surround and Center output off 
immediately. 
Input current stabilised at 1,40A. 
F905, F906 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
 
 
- Page 5 of 8 - 
 
 
www.nemko.com
 
Report No.  65681 
 
 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse (A)
Mains power/temperatures/results 
C915 
S - c 
253 
10min 
F907 
F903 
F904 
3,90 
Front and S/B Multi output off  
immediately. 
Input current stabilised at 1,17A. 
F903, F904 opened. 
No hazard. 
(Repeated test three times with the 
same result) 
C915 
S - c 
207 
10min 
F907 
F903 
F904 
Front and S/B Multi output off  
immediately. 
Input current stabilised at 1,10A. 
F903, F904 opened. 
No hazard. 
(Repeated test three times with the 
same result) 
IC94 
S - c 
253 
Pin 1 - 2  10min 
F907 
2,23 
Normal operated. 
Input current stabilised at 2,23A. 
R950, R948 opened. 
No hazard. 
IC94 
S - c 
253 
Pin 1 - 3  10min 
F907 
2,31 
Normal operated. 
Input current stabilised at 2,31A. 
No component damaged. 
No hazard. 
D962 
S - c 
253 
7min 
24sec 
F907 
2,30 
Sub transformer primary winding he
ated up to 103.8K and thermal fuse 
open after 7min 24sec. 
Dielectric strength test ok. 
No hazard. 
C906 
S - c 
253 
5min 
8sec 
F907 
0,08 
Unit shut down immediately. 
Sub transformer primary winding 
heated up to 101.9K and thermal fu
se open after 5min 8sec. 
Dielectric strength test ok. 
No hazard. 
C911 
S - c 
253 
7min 
6sec 
F907 
0,08 
Unit shut down immediately. 
Sub transformer primary winding he
ated up to 102,8K and thermal fuse 
open after 7min 6sec. 
Dielectric strength test ok. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 
 
 
 
- Page 6 of 8 - 
 
 
www.nemko.com
 
Report No.  65681 
 
 
 
 
11 
FAULT CONDITIONS TESTS-continued
 
Comp. 
No. 
Fault Test 
V Short 
current 
Test 
time 
Fuse No Current 
through 
fuse (A)
Mains power/temperatures/results 
C907 
S - c 
253 
19min 
50sec 
F907 
0,05 
Unit shut down immediately. 
Sub transformer primary winding he
ated up to 101,3K and thermal fuse 
open after 19min 50sec. 
Dielectric strength test ok. 
No hazard. 
FAN 
(built-in 
rear 
panel) 
Locked 253 
3hr 
F907 
2,24 
Normal 
operated. 
The components are heated up to :
-Main transf. pr. Winging  :82,4K 
-Main transformer core 
:68,1K 
-Sub transf. pr. Winging  :61,0K 
-Sub transformer core 
:57,9K 
-PWB near Q803 
:60,0K 
-PWB near D991 
:88,3K 
and stabilised. 
Dielectric strength test ok. 
No hazard. 
FAN 
(built-in 
main 
heat-sink
)
 
Locked 253 
2hr 
45min 
F907 2,24 Normal 
operated. 
The components are heated up to :
-Main transf. pr. Winging  :72,6K 
-Main transformer core 
:48,1K 
-Sub transf. pr. Winging  :46,0K 
-Sub transformer core 
:39,6K 
-PWB near Q803 
:53,3K 
-PWB near D991 
:66,5K 
and stabilised. 
Dielectric strength test ok. 
No hazard. 
Top 
cover 
opening 
Block 253  - 
18min 
55sec 
F907 
2,24 
Unit shut down after 18min 55sec. 
Input current stabilised 0,02A. 
No component damaged. 
No hazard. 
Speaker 
terminal 
S – c 
253 
10min 
F907 
Unit shut down immediately. 
Input current stabilised 0,02A. 
No component damaged. 
No hazard. 
Pmax 
operating 
Maximun
 non-
clipped o
utput sig
nal 
253 - 
1hr 
40min 
F907 
4,97 
Front and S/B Mult output signal off
after 18min. 
Rear and Center output signal off 
after 1hr 25min. 
Input current stabilised at 0,31A. 
F903, F904, F905, F906 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection 