- Page 20 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Not soldered to conductors of a printed circuit 
board 
Not soldered 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
Wires are clamped two times 
to the contact terminal and 
provided with a two-pole 
connector 
 
Wire secured by additional means to the conductor
Adequately anchored.  
Tested with 5 N. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
No screws and nuts clamping  
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
No soldered conductors 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Clamped insulators and 
conductors
 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
Terminals have adequate 
connection capacity. 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
No clamps. 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
No contact pressure 
transmitted through insulating 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
The termination of the 
contacts are in adequate 
proximity to each other. 
 
Terminals located and shielded: test with 8 mm 
strand 
Clamped contacts within 
connector 
15.4 
Devices forming a part of the mains plug 
 N 
15.4.1 
No undue strain on mains socket-outlets 
The apparatus is not a device 
forming a part of the mains 
plug. 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
 
 
- Page 21 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 
 
 
 
16 
EXTERNAL FLEXIBLE CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ............................................................ :
Sheathed PVC cord 
complying with IEC 60227 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II apparatus 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
The cord is 0,75mm², within the 
current rating 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of  
equipment used in combination and carrying  
hazardous live voltages, have adequate dielectric 
strength 
No interconnecting cables 
comprising hazardous live 
conductors. 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
Cord complying with 16.1.
 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
Cords have adequate cross-
sectional areas to avoid 
temperature rise under normal 
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords 
Cord clip wedged in the 
enclosure 
 
Not possible to push cord back into equipment 
Checked by inspection 
 
Strain relief device unlikely to damage flexible cord
No sharp edges 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth 
conductor 
Class II apparatus 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
No sharp edges 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
The apparatus is not a 
transportable musical 
instrument and amplifier 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
The apparatus is not a 
transportable musical 
instrument and amplifier 
 
 
- Page 22 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
17 ELECTRICAL 
CONNECTIONS 
AND MECHANICAL FIXINGS 
 
17.1 
Torque test to table 20: 
Screws fixing chassis to the 
main enclosure tested. 
 
- screws into metal: 5 times 
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
- screws into non-metallic material: 10 times 
 
17.2 
Correct introduction into female threads in non-
metallic material 
No female threads in non-
metallic materials 
17.3 
Cover fixing screws: captive 
Captivity not necessary 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A 
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0,2 A 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder 
No screw terminals. 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
No cover fixing devices other 
than screws 
17.8 
Fixing devices for detachable legs or stands 
provided 
No detachable provided 
 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
Connections complies, 
checked by inspection 
 
 
- Page 23 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
 
Picture tube separately approved to IEC 61965: 
No CRT in the equipment 
 
Picture tube separately approved to 18.1 ...............
 
18.1 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used with 
protective screen 
 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 7 kg  ................. :
Weight: 14,4 kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
Tested on a plane inclined at 
an angle of 10° 
19.2 
100 N force applied vertically downwards 
100N force have no influence 
on the stability 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
< 25 kg, < 1M 
19.4 
Edges or corners not hazardous 
There is no hazardous edges 
or corners when the 
apparatus is operating in 
normal position 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
19.6 
Wall or ceiling mountings adequate 
Not intended for wall or ceiling 
mounting 
Page of 50