Harman Kardon AVR 340 (serv.man12) EMC - CB Certificate ▷ View online
- Page 28 of 33 -
www.nemko.com
Report No. 65681
TRF No: IEC/EN 60065F
7.2
TABLE: softening temperature of thermoplastics
N
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
2
Between parts separated by double or reinforced insulation
> 100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500V No
Between parts separated by double or reinforced insulation
3000V No
- Page 29 of 33 -
www.nemko.com
Report No. 65681
TRF No: IEC/EN 60065F
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Main
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
Wintech Ploymer.
Therm-O-Disc.
& Telecom Co Ltd.
Wintech Ploymer.
Therm-O-Disc.
KLT5W022ZE
CLT5W022ZE
CN9030
E4A51167C
CLT5W022ZE
CN9030
E4A51167C
230V Class B
V-0, 155°C
V-0, 155°C
10A/250V 167°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL E213445
VDE
UL E213445
VDE
Sub
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
LG Chemical Ltd..
Anzen Dengu Co
& Telecom Co Ltd.
LG Chemical Ltd..
Anzen Dengu Co
KLT5J038ZE
CLT5J038ZE
GP2306F(#)
K11
CLT5J038ZE
GP2306F(#)
K11
230V Class E
V-0, 140°C
V-0, 140°C
1A/250V, 115°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL E67171
VDE
UL E67171
VDE
Mains plug/cord
(For CENELEC)
(For CENELEC)
KENIC ELECTRIC. KE-25
H03VVH2-F
10-16A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt.
VOLEX (ASIA) PTE. M3204
H03VVH2-F
10-16A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt.
HWAJIN KDK CO.
KKP-4819C
H03VVH2-F
H03VVH2-F
10-16A/250V
6A/250V
6A/250V
IEC60884-1 VDE
Mains plug/cord
(For UK and
Singapore)
(For UK and
Singapore)
KENIC ELECTRIC. KE-108
H03VVH2-F, or
H05VVH2-F
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
SS145
SS145
BSI
PSB
PSB
Mains plug/cord
(For UK)
(For UK)
VOLEX (ASIA) PTE. MP5005
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
ASTA
alt.
VOLEX (ASIA) PTE MP5004A
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
ASTA
alt.
PHINO ELECT.
PHP-307F
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
WINBO INDUSTRIE
S
S
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
LUEN TAI (IP`S).
KENIC ELECT.
KENIC ELECT.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
WELL SHIN ENT.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
Socket-outlet
(OL91)
(OL91)
Dae Ryung Elect.
A3-04-D007
2.5A/250V ~
IEC60884-1
NEMKO
Mains switch
(SW1)
(SW1)
POSTEC Electric.
SDL1P-B
5A/80A 250V
IEC60065
IEC61058-1
VDE
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
- Page 30 of 33 -
www.nemko.com
Report No. 65681
TRF No: IEC/EN 60065F
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Mains relay
(RY94)
(RY94)
Tyco Electronics
SDT-S-112DMR 8A/120A 250V
IEC60065
IEC 61058-1
IEC 61058-1
SEMKO
Mains fuse
(F907)
alt.
alt.
(F907)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Outlet fuse
(F901, F902)
alt.
alt.
(F901, F902)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T2.5A 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Sec. fuse
(F903, F904)
(F903, F904)
Orisel Co Ltd.
Littelfuse Inc.
Littelfuse Inc.
S51
218
218
008
SB 8A 250V
UL198G
UL
UL
UL
Sec. fuse
(F905, F906)
alt.
alt.
(F905, F906)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Switch across
cap (C853) *)
alt.
alt.
alt.
cap (C853) *)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
Relay across
the cap (C904)
alt.
alt.
alt.
the cap (C904)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
X-cap. (C124)
alt.
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Elect.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Elect.
PCX2 335M
KNB1530
RE104
WBU1942
KNB1530
RE104
WBU1942
0.10uF 275V
X2
X2
IEC60384-14,
2
2
nd
ed.
FIMKO
VDE
VDE
FIMKO
VDE
VDE
FIMKO
DC B/less Fan
alt.
alt.
SUNONWEALTH
Colorful Industrial
Colorful Industrial
KD1206PTS3
CF-12625SA
CF-12625SA
12V, 0.8A, 16CFM
12V, 1.2W,
12V, 1.2W,
17.5CFM
IEC60950 TUV
TUV
*) Optional component
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
- Page 31 of 33 -
www.nemko.com
Report No. 65681
TRF No: IEC/EN 60065F
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Body, top cover
Front panel
alt.
Display window
alt.
Front panel
alt.
Display window
alt.
Various
Kumho Chemical
LG Chemical
Mitsubishi Rayon
Mitsubishi Rayon
Kumho Chemical
LG Chemical
Mitsubishi Rayon
Mitsubishi Rayon
Various
HFA-452
AF-308
L530
MR100
HFA-452
AF-308
L530
MR100
Sheet Steel,
Min. 0.80 mm
ABS, V-2,
Min. 2.0 mm
PMMA, 94HB
Min. 2.0 mm
Min. 0.80 mm
ABS, V-2,
Min. 2.0 mm
PMMA, 94HB
Min. 2.0 mm
-
UL94
UL94
UL94
UL94
UL94
UL94
UL94
UL94
1.)
UL, E65424
UL, E67171
UL, E54695
UL, E54695
UL, E65424
UL, E67171
UL, E54695
UL, E54695
PCB base Mtl.
Various
Various
Min. V-1, 105
°C
UL 796
UL
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
Click on the first or last page to see other AVR 340 (serv.man12) service manuals if exist.