Report No. 65681
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location Measured
U1
V (peak)
Measured U1
V (DC)
V (DC)
Measured U2
V (peak)
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 - Antenna terminal
Pole 2 - Antenna terminal
Pole 2 - Antenna terminal
-
-
-
-
-
-
0,02 V peak
0.02 V peak
0.02 V peak
Pass
Pass
Pass
Pole 1 - other part or contact
Pole 2 - other part or contact
Pole 2 - other part or contact
-
-
-
-
-
-
0,02 V peak
0.02 V peak
0.02 V peak
Pass
Pass
Pass
Comments:
Only U2 have been recorded due to the use of a linear transformer in power supply.
- Page 2 of 8 -
www.nemko.com
Report No. 65681
11
FAULT CONDITIONS TESTS
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V
—
Ambient temperature (
o
C) ...................................... :
24 -26
°C
—
Comp.
No.
No.
Fault Test
V Short
current
Test
time
time
Fuse No Current
through
fuse (A)
fuse (A)
Mains power/temperatures/results
D991
S - c
253
AC - ‘+’ 10min
F907
F903
F904
F903
F904
4,26 Normal
operated.
Input current stabilised at 2,18A.
F904 opened.
No hazard.
(Repeated test three times with the
same result)
F904 opened.
No hazard.
(Repeated test three times with the
same result)
D991
S - c
207
AC - ‘+’ 10min
F907
F903
F904
F903
F904
5,03 Normal
operated.
Input current stabilised at 2,06A.
F904 opened.
No hazard.
(Repeated test three times with the
same result)
F904 opened.
No hazard.
(Repeated test three times with the
same result)
D991
S - c
253
AC - ‘-‘
10min
F907
F903
F904
F903
F904
4,13 Normal
operated.
Input current stabilised at 2,13A.
F903 opened.
No hazard.
(Repeated test three times with the
same result)
F903 opened.
No hazard.
(Repeated test three times with the
same result)
D992
S - c
253
AC - ‘+’ 10min
F907
F905
F906
F905
F906
9,0 Normal
operated.
Input current stabilised at 2,20A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
S - c
207
AC - ‘+’ 10min
F907
F905
F906
F905
F906
4,20 Normal
operated.
Input current stabilised at 2,12A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
S - c
253
AC - ‘-’
10min
F907
F905
F906
F905
F906
4,50 Normal
operated.
Input current stabilised at 2,18A.
F905 opened.
No hazard.
F905 opened.
No hazard.
C122
S - c
253
-
10min
F907
2,33
FL display off immediately.
Input current stabilised at 2,18A
R101 opened..
No hazard.
Input current stabilised at 2,18A
R101 opened..
No hazard.
C120
S - c
253
-
15min
F907
2,25
FL display off immediately.
Input current stabilised at 2,24A.
No component damaged.
No hazard.
Input current stabilised at 2,24A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection