- Page 16 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.5.1.1 
a) Thermal cut-outs separately approved 
None 
 
b) Thermal cut-outs tested as part of the 
submission 
 
14.5.1.2 
a) Thermal links separately approved 
The thermal link in main  
transformer, separately  
approved, see appended table,
 list of critical components. 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are certified according 
to IEC60127 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :
Correct marking applied close 
to the fuse; 
F901, F902: T2.5A L 250V, 
F903, F904: T8A L 250V, 
F905 - F907: T6.3A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel ............... :
No fuse holder so designed that 
fuse-links can be connected in 
parallel 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
No replacement of fuse  
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
None 
 
PTC-S devices (15 W) category V-1 or better 
None 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
Secondary F903, and F904 
fuses have adequately 
breaking capacity. Fault 
condition repeated three times 
where one of the above fuse 
opened. 
14.6 Switches 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
Yes,  
Mains switch and relay provided. 
Certified acc. to IEC61058-1.  
- Mains switch, certified by VDE, 
-
 Mains relay, certified by SEMKO. 
 
See appended table, list of criti
cal components. 
 
 
- Page 17 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.6.1 b) 
Tested in the apparatus: 
 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
Separately approved switch an
d relay. 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
Separately approved switch an
d relay. 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
Separately approved switch an
d relay. 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
Apparatus surge : 50A 
Socket-outlet surge : 20A 
Total surge : 70A 
 
The measured surge current 
value is less than rated surge 
current rating of the mains 
relay and switch. OK. 
 
Socket outlet current marking correct 
Socket outlet marking: 
UNSWTCHED (100W MAX, 0.5A) 
SWITCHED (50W MAX, 0.25A)
 
14.7 Safety 
interlocks 
No safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
14.8 
Voltage setting devices 
No voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 
14.9 Motors 
DC brush-less fan motor 
14.9.1 
Endurance test on motors 
 
 
Motor start test 
 
 
Dielectric strength test 
Only DC supplied 
 
 
- Page 18 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.9.2 
Not adversely affected by oil or grease etc. 
The fan is not adversely affecte
d by oil, grease or other 
substances  
14.9.3 
Protection against moving parts 
The fan is placed inside the uni
t. No access. 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
No such construction. 
14.10 Batteries 
No batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 
14.10.3 
Recharging currents and times within manufacture
rs limits 
 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 
14.10.4 
Battery mould stress relief 
 
14.10.5 
Battery drop test 
 
14.11 Optocouplers 
No optocouplers 
 
Optocouplers comply with Cl. 8 
 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
 
14.12 
Surge suppression varistors 
No surge suppression varistors 
 
Comply with IEC 61051-2 
 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 
 
 
- Page 19 of 33 - 
 
 
www.nemko.com
 
Report No.  65681 
 
TRF No:  IEC/EN 60065F 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
Approved mains plug and sock
et-
outlet provided, see list of critic
al components. 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
Only RCA, Mini jack, Optical, 
Antenna, S-video and DMP 
terminal used. Banana plug 
type speaker terminal also 
used, but they are accepted 
due to below note. 
 
Note:  
Banana plug type speaker  
terminals are blocked in their  
axial holes to prevent use of plugs
 that can make permanent contac
t with a mains socket outlet. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
No sockets indicated with the 
symbol 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
The equipment under test is 
not an adaptor. 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II apparatus
 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance  test: < 0,1 
Ω at 25 A ................... :
 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
Apparatus is not for permanent 
connection. 
15.3.2 
Reliable connection of non-detachable cords: 
 