Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 22 of 39 -
Order
No.
51563
14.5.1.3
Thermal devices reset table by
soldering
soldering
No such thermal device
N
14.5.2.1
Fuse-links in the mains circuit
according to IEC 60 127
according to IEC 60 127
See list below :
P
Circuit Manufacturer
Dimen-
Approved Marking
of
Marking
Current
diagram
sions
by
rated current,
close to
through
informa-
pre-arcing time
the com-
the fuse
tion
and current
ponent
in normal
Part No
characteristic
operation
F901, F902
(pr.)
Littlefuse
8.5
φ
VDE
T 2.5A 250V
T 2.5A L 250V
< 0,50A
F903, F904
(sec)
Orisel Co, Ltd.
5 x 20mm
UL
SB 8A 250V
T 8A L 250V
3,19A
F905, F906
(sec)
Orisel Co, Ltd.
5 x 20mm
VDE
T 6.3A L 250V
T 6.3A L 250V
2,59A
F907
(pr.)
Orisel Co, Ltd.
5 x 20mm
VDE
T 6.3A L 250V
T 6.3A L 250V
2,24A
14.5.2.2
Correct marking of fuse-links
adjacent to holder
adjacent to holder
Correct marking applied close to the fuse, see table
above.
above.
P
14.5.2.3
Not possible to connect fuses in
parallel
parallel
No fuse holder so designed that fuse-links can be
connected in parallel
connected in parallel
P
14.5.2.4
Not possible to touch hazardous
live parts when replacing fuse-links
without the use of a tool
live parts when replacing fuse-links
without the use of a tool
No replacement of fuse possible by hand.
P
14.5.3
PTC-S thermistors comply with
IEC 60 738
IEC 60 738
No PTC’s
N
PTC-S devices (>15 W) category
FV 1 or better
FV 1 or better
N
14.5.4
Other protective devises.
Circuit protectors have adequate
breaking capacity and their position
is correctly marked
Circuit protectors have adequate
breaking capacity and their position
is correctly marked
Secondary F903, F904 fuses (2 type) have adequately
breaking capacity. Fault condition repeated three times
each where one of the above fuses opened.
breaking capacity. Fault condition repeated three times
each where one of the above fuses opened.
P
14.6 Switches
P
Manually operated mechanical
switch (MOMS) conductively
connected to the mains
switch (MOMS) conductively
connected to the mains
MOMS provided
P
Part No
Function
Manufacturer
Type
Rated
Marking
Marking
All-
One
Name
Trademark
V
A
Surge
pole
pole
current
SW01 X POSTEC
Electronics -
SDL1P-B
250 5
80A
RY94 X Tyco
Electronics. OEG
SDT-S-112DMR
250 8
120A
-
IEC 60065, 6th edition : 1998
-
- Page 23 of 39 -
Order
No.
51563
14.6.1
Permanently connected equipment
provided with an all-pole mains
switch unless 5.4.2 is met
provided with an all-pole mains
switch unless 5.4.2 is met
Apparatus is not permanently connected
N
14.6.2
Manually operated mechanical
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
Yes. MOMS required. See table above.
P
Switch readily accessible and not in
mains cord
mains cord
Switch located on the front and readily accessible
P
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical
switch (MOMS): Switch indication /
On position clearly discernible
switch (MOMS): Switch indication /
On position clearly discernible
The display is illuminated.
P
Indication by marking meets Cl. 5
Yes
P
Indication of the OFF position
Off-position marked with “OFF”
P
14.6.4
Manually operated mechanical
switch (MOMS) fitted. Is there a
Stand-by mode
switch (MOMS) fitted. Is there a
Stand-by mode
Yes
P
Stand-by mode clearly discernible
LED indication
P
Exception for low Stand-by current
< 0,7 mA (peak)
< 0,7 mA (peak)
N
14.6.5
Components bridging contacts of
mains switches comply with 14.1 a)
or 14.2.2
mains switches comply with 14.1 a)
or 14.2.2
Yes, C904 for relay contacts.
See clause 14.2.
See clause 14.2.
P
14.6.6.a.
Manually operated mechanical
switches (MOMS) separately
approved to IEC 61 058-1
switches (MOMS) separately
approved to IEC 61 058-1
Yes, certified by,
- VDE for main switch,
- SEMKO for mains relay
- VDE for main switch,
- SEMKO for mains relay
P
14.6.6.b.
Manually operated mechanical
switch (MOMS) tested as part of
the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and
meets 14.6.8 and/or 14.6.9 and
Annex G (G.1.1)
switch (MOMS) tested as part of
the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and
meets 14.6.8 and/or 14.6.9 and
Annex G (G.1.1)
N
Flame test for mains switches
N
14.6.7 Endurance
test
Switch and Relay, separately certified.
N
14.6.8
Temperature rise in mains switch
Switch and Relay, separately certified.
N
14.6.9
Dielectric strength test
Switch and Relay, separately certified.
N
-
IEC 60065, 6th edition : 1998
-
- Page 24 of 39 -
Order
No.
51563
14.6.10
Surge current for mains switches
also controlling mains socket-
outlets
also controlling mains socket-
outlets
Measured mains relay surge current : 50A
Measured mains switch surge current : <1A
Socket-outlet through current (50W) : 20A
Mains relay controlling total current
Measured mains switch surge current : <1A
Socket-outlet through current (50W) : 20A
Mains relay controlling total current
: 50A+20A=70A
The measured surge current value is less than rated
surge current rating of the mains relay and switch. OK.
Ref. clause 7.
P
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to
be changed accidentally
be changed accidentally
No voltage selector
N
14.9 Motors
P
14.9.1
Endurance test on motors
Only DC low voltage secondary connected motors for
fan, no further testing required.
fan, no further testing required.
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
The fan is not adversely affected by oil, grease or other
substances.
substances.
P
14.9.3
Protection against moving parts
The fan is placed inside the unit. No access.
P
14.9.4
Motors with phase-shifting
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
Not such construction.
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of
accumulation of flammable gases
accumulation of flammable gases
No batteries
N
14.10.2
No possibility of recharging non-
rechargeable batteries
rechargeable batteries
N
14.10.3
Recharging currents and times
within manufacturers limits
within manufacturers limits
N
Lithium batteries discharge and
reverse currents within the
manufacturers limits
reverse currents within the
manufacturers limits
No lithium battery
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
No optocouplers.
N
Internal and external dimensions to
13.1.1
13.1.1
N
-
IEC 60065, 6th edition : 1998
-
- Page 25 of 39 -
Order
No.
51563
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer
Type
Standard Certified
Remarks
sheet
by
(colour
etc.)
Mains plug
KENIC
KE-25
IEC 60884-1
VDE
10-16A / 250V
Mains socket-outlet
Dae Ryung Elect.
A3-04-D007
IEC 60884-1
NEMKO
2,5A 250V~, black
Mains sockets and interconnection
couplers
couplers
The socket outlet on the Class II apparatus does only
permit connection of other Class II apparatus.
permit connection of other Class II apparatus.
P
Overload protection for
socket-outlets
socket-outlets
Overload protection provided with a fuse :
F901, F902 (T2.5A 250V)
F901, F902 (T2.5A 250V)
P
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Only RCA, Mini jack, Optical, Antenna, S-video and DMP
terminal used. Banana plug type speaker terminal also
used, but they are accepted due to below note.
terminal used. Banana plug type speaker terminal also
used, but they are accepted due to below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
15.2
Provision for protective earthing
Class II apparatus
N
Accessible conductive parts of
Class I equipment reliably
connected to earth terminal, within
equipment.
Class I equipment reliably
connected to earth terminal, within
equipment.
N
Switches or fuses in protective
earth circuits
earth circuits
N
Class I supply apparatus with non-
hazardous live output voltage:
output circuit not connected to earth
hazardous live output voltage:
output circuit not connected to earth
N
Protective earth conductors
correctly coloured
correctly coloured
N