Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 22 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
14.5.1.3 
Thermal devices reset table by 
soldering  
No such thermal device 
14.5.2.1 
Fuse-links in the mains circuit 
according to IEC 60 127   
See list below : 
Circuit Manufacturer 
Dimen- 
Approved Marking 
of 
Marking 
Current 
diagram 
 
sions 
by 
rated current, 
close to 
through 
informa- 
 
 
 
pre-arcing time
the com- 
the fuse   
tion 
 
 
 
and current 
ponent 
in normal 
Part No 
 
 
 
characteristic 
 
operation   
F901, F902 
(pr.)
 Littlefuse 
8.5
φ 
VDE 
T 2.5A 250V 
T 2.5A L 250V 
< 0,50A 
F903, F904 
(sec)
 
Orisel Co, Ltd. 
5 x 20mm
UL 
SB 8A 250V 
T 8A L 250V 
3,19A 
F905, F906 
(sec)
 
Orisel Co, Ltd. 
5 x 20mm
VDE 
T 6.3A L 250V
T 6.3A L 250V 
2,59A 
F907 
(pr.)
 
Orisel Co, Ltd. 
5 x 20mm
VDE 
T 6.3A L 250V
T 6.3A L 250V 
2,24A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
14.5.2.2 
Correct marking of fuse-links 
adjacent to holder      
Correct marking applied close to the fuse, see table 
above. 
14.5.2.3 
Not possible to connect fuses in 
parallel    
No fuse holder so designed that fuse-links can be 
connected in parallel 
14.5.2.4 
Not possible to touch hazardous 
live parts when replacing fuse-links 
without the use of a tool      
No replacement of fuse possible by hand. 
14.5.3 
PTC-S thermistors comply with 
IEC 60 738   
No PTC’s 
 
PTC-S devices (>15 W) category 
FV 1 or better   
 
14.5.4 
Other protective devises. 
Circuit protectors have adequate 
breaking capacity and their position 
is correctly marked   
Secondary F903, F904 fuses (2 type) have adequately 
breaking capacity. Fault condition repeated three times 
each where one of the above fuses opened. 
14.6 Switches 
 
 
 
Manually operated mechanical 
switch (MOMS) conductively 
connected to the mains
 
 
MOMS provided 
Part No 
Function 
Manufacturer 
Type 
Rated 
Marking 
 All- 
One 
Name 
Trademark 
 
Surge 
 pole 
pole 
 
 
 
  
current 
 
 
 
 
 
 
 
 
 
SW01   X  POSTEC 
Electronics - 
SDL1P-B 
250  5 
80A 
RY94   X Tyco 
Electronics.  OEG 
SDT-S-112DMR 
250  8 
120A 
 
 
 
 
 
 
 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 23 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
14.6.1 
Permanently connected equipment 
provided with an all-pole mains 
switch unless 5.4.2 is met   
Apparatus is not permanently connected 
 
14.6.2 
Manually operated mechanical 
switch (MOMS), required where 
power consumption > 15 W and/or 
peak voltage > 4 kV 
Yes. MOMS required. See table above. 
 
 
Switch readily accessible and not in 
mains cord   
Switch located on the front and readily accessible 
 
Exception for automatic switching   
 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical 
switch (MOMS): Switch indication / 
On position clearly discernible   
The display is illuminated. 
 
 
Indication by marking meets Cl. 5   
Yes 
 
Indication of the OFF position   
Off-position marked with “OFF” 
14.6.4 
Manually operated mechanical 
switch (MOMS) fitted. Is there a 
Stand-by mode      
Yes 
 
Stand-by mode clearly discernible    
LED indication 
 
Exception for low Stand-by current 
< 0,7 mA (peak)   
 
14.6.5 
Components bridging contacts of 
mains switches comply with 14.1 a) 
or 14.2.2   
Yes, C904 for relay contacts. 
See clause 14.2. 
14.6.6.a. 
Manually operated mechanical 
switches (MOMS) separately 
approved to IEC 61 058-1 
Yes, certified by, 
- VDE for main switch, 
- SEMKO for mains relay 
14.6.6.b. 
Manually operated mechanical 
switch (MOMS) tested as part of 
the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and 
meets 14.6.8 and/or 14.6.9 and 
Annex G (G.1.1)   
 
 
Flame test for mains switches 
 
14.6.7 Endurance 
test 
Switch and Relay, separately certified. 
14.6.8 
Temperature rise in mains switch 
Switch and Relay, separately certified. 
14.6.9 
Dielectric strength test 
Switch and Relay, separately certified. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 24 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
14.6.10 
Surge current for mains switches 
also controlling mains socket-
outlets 
Measured mains relay surge current  : 50A 
Measured mains switch surge current : <1A 
Socket-outlet through current (50W)  : 20A 
Mains relay controlling total current 
: 50A+20A=70A 
 
The measured surge current value is less than rated 
surge current rating of the mains relay and switch. OK. 
Ref. clause 7. 
14.7 Safety 
interlocks 
 
 
 
Safety interlocks to 2.8 of 
IEC 60 950   
No safety interlock 
14.8 
Voltage setting devices 
 
 
 
Voltage setting device not likely to 
be changed accidentally   
No voltage selector 
 
14.9 Motors 
 
 
14.9.1 
Endurance test on motors   
Only DC low voltage secondary connected motors for 
fan, no further testing required. 
 
Motor start test   
 
 
Dielectric strength test   
 
14.9.2 
Not adversely affected by oil or 
grease etc.   
The fan is not adversely affected by oil, grease or other 
substances. 
14.9.3 
Protection against moving parts   
The fan is placed inside the unit. No access. 
14.9.4 
Motors with phase-shifting 
capacitors, three-phase motors and 
series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60 950, Annex B   
Not such construction. 
14.10 Batteries 
 
 
14.10.1 
Batteries mounted with no risk of 
accumulation of flammable gases   
No batteries 
14.10.2 
No possibility of recharging non-
rechargeable batteries   
 
14.10.3 
Recharging currents and times 
within manufacturers limits   
 
 
Lithium batteries discharge and 
reverse currents within the 
manufacturers limits   
No lithium battery 
14.11 Optocouplers 
 
 
 
Optocouplers comply with Cl. 8   
No optocouplers. 
 
 
Internal and external dimensions to 
13.1.1  
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 25 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
15 TERMINALS 
 
 
15.1.1 
Mains plug, appliance inlet, 
interconnection couplers and mains 
socket-outlet meet the appropriate 
standard  
See list below. 
Component Manufacturer 
Type 
Standard Certified 
Remarks 
  
 
sheet 
by 
(colour 
etc.) 
Mains plug 
KENIC 
KE-25 
IEC 60884-1 
VDE 
10-16A / 250V 
Mains socket-outlet 
Dae Ryung Elect. 
A3-04-D007 
IEC 60884-1 
NEMKO 
2,5A 250V~, black 
 
 
 
 
 
 
 
 
 
 
 
 
 
Mains sockets and interconnection 
couplers 
The socket outlet on the Class II apparatus does only 
permit connection of other Class II apparatus. 
 
Overload protection for   
socket-outlets 
Overload protection provided with a fuse :   
F901, F902 (T2.5A 250V) 
15.1.2 
Connectors for antenna, earth, 
audio, video or data: 
 
 
 
No risk of insertion in mains 
socket-outlets  
Only RCA, Mini jack, Optical, Antenna, S-video and DMP 
terminal used. Banana plug type speaker terminal also   
used, but they are accepted due to below note. 
 
Note: 
Banana plug type speaker terminals are blocked in their 
axial holes to prevent use of plugs that can make 
permanent contact with a mains socket outlet. 
 
Sockets for audio and video circuits 
indicated with the symbol of 5.2.b. 
 
No sockets indicated with the symbol 
 
15.1.3 
Output terminals of AC adaptors or 
similar devices not compatible with 
household mains socket-outlets   
 
15.2 
Provision for protective earthing 
 
Class II apparatus 
 
Accessible conductive parts of 
Class I equipment reliably 
connected to earth terminal, within 
equipment.  
 
 
Switches or fuses in protective 
earth circuits 
 
 
Class I supply apparatus with non-
hazardous live output voltage: 
output circuit not connected to earth 
 
 
Protective earth conductors 
correctly coloured   
 
Page of 53