Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 38 of 39 -
Order
No.
51563
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test
time
time
Fuse No
Current
through
fuse (A)
through
fuse (A)
Mains power/temperatures/results
IC94
S – c
253
Pin 1 – 2 10min
F907
2,23
Normal operated.
Input current stabilised at 2,23A.
R950, R948 opened.
No hazard.
Input current stabilised at 2,23A.
R950, R948 opened.
No hazard.
IC94
S – c
253
Pin 1 – 3 10min
F907
2,31
Normal operated.
Input current stabilised at 2,31A.
No component damaged.
No hazard.
Input current stabilised at 2,31A.
No component damaged.
No hazard.
D962
S – c
253
-
7min
24sec
24sec
F907
2,30
Sub transformer primary winding
heated up to 103.8K and thermal
fuse open after 7min 24sec.
Dielectric strength test ok.
No hazard.
heated up to 103.8K and thermal
fuse open after 7min 24sec.
Dielectric strength test ok.
No hazard.
C906
S – c
253
-
5min
8sec
8sec
F907
0,08
Unit shut down immediately.
Sub transformer primary winding
heated up to 101.9K and thermal
fuse open after 5min 8sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding
heated up to 101.9K and thermal
fuse open after 5min 8sec.
Dielectric strength test ok.
No hazard.
C911
S – c
253
-
7min
6sec
6sec
F907
0,08
Unit shut down immediately.
Sub transformer primary winding
heated up to 102,8K and thermal
fuse open after 7min 6sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding
heated up to 102,8K and thermal
fuse open after 7min 6sec.
Dielectric strength test ok.
No hazard.
C907
S – c
253
-
19min
50sec
50sec
F907
0,05
Unit shut down immediately.
Sub transformer primary winding
heated up to 101,3K and thermal
fuse open after 19min 50sec.
Dielectric strength test ok.
No hazard.
Sub transformer primary winding
heated up to 101,3K and thermal
fuse open after 19min 50sec.
Dielectric strength test ok.
No hazard.
FAN
(built-in
rear
panel)
(built-in
rear
panel)
Locked 253
-
3hr
F907
2,24
Normal
operated.
The components are heated up to :
-Main transf. pr. Winging :82,4K
-Main transformer core
-Main transf. pr. Winging :82,4K
-Main transformer core
:68,1K
-Sub transf. pr. Winging
:61,0K
-Sub transformer core
:57,9K
-PWB near Q803
:60,0K
-PWB near D992
:71,8K
-PWB near D991
:88,3K
and stabilised.
Dielectric strength test ok.
No hazard.
Dielectric strength test ok.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 39 of 39 -
Order
No.
51563
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test
time
time
Fuse No
Current
through
fuse (A)
through
fuse (A)
Mains power/temperatures/results
FAN
(built-in
main
(built-in
main
heat-sink
)
Locked 253
-
2hr
45min
45min
F907 2,24 Normal
operated.
The components are heated up to :
-Main transf. pr. Winging :72,6K
-Main transformer core
-Main transf. pr. Winging :72,6K
-Main transformer core
:48,1K
-Sub transf. pr. Winging
:46,0K
-Sub transformer core
:39,6K
-PWB near Q803
:53,3K
-PWB near D992
:47,9K
-PWB near D991
:66,5K
and stabilised.
Dielectric strength test ok.
No hazard.
Dielectric strength test ok.
No hazard.
Top
cover
opening
cover
opening
Block 253 -
18min
55sec
55sec
F907
2,24
Unit shut down after 18min 55sec.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Speaker
terminal
terminal
S – c
253
-
10min
F907
-
Unit shut down immediately.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Input current stabilised 0,02A.
No component damaged.
No hazard.
Pmax
operating
operating
Maximun
non-
clipped
output
signal
non-
clipped
output
signal
253 -
1hr
40min
40min
F907
4,97
Front and S/B Mult output signal off
after 18min.
Rear and Center output signal off
after 1hr 25min.
Input current stabilised at 0,31A.
F903, F904, F905, F906 opened.
No hazard.
after 18min.
Rear and Center output signal off
after 1hr 25min.
Input current stabilised at 0,31A.
F903, F904, F905, F906 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 1 of 3 -
Order No. 51563
APPENDIX
CENELEC EN 60065:1998
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS,
NATIONAL DEVIATIONS AND OTHER INFORMATION
NATIONAL DEVIATIONS AND OTHER INFORMATION
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
DE = Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE =
Sweden.
P = Pass, F = Fail, N = Not applicable.
Sweden.
P = Pass, F = Fail, N = Not applicable.
1.1.1
C
Replace text in Note 1 by : This
standard can be used as a guide for the
testing of battery operated apparatus
standard can be used as a guide for the
testing of battery operated apparatus
N
2.6.1
S
(DK) Class I apparatus provided with a
plug not establishing earthing continuity
when inserted in Danish socket-outlets,
see 15.1.1.
plug not establishing earthing continuity
when inserted in Danish socket-outlets,
see 15.1.1.
Class II apparatus
N
3.1
C
Delete the note. Add the following
indent : exposure to excessive sound
pressures from headphones or
earphones.
indent : exposure to excessive sound
pressures from headphones or
earphones.
5
D
(DE) Marking in case of intrinsically
ionizing radiation, cathode-ray tubes
ionizing radiation, cathode-ray tubes
N
5
D
(IT) Marking and instruction
requirements
- power consumption (W) for TV
receivers
requirements
- power consumption (W) for TV
receivers
N
6.1
D
(DE) Limits for ionizing radiation, TV
receivers (max. 1
receivers (max. 1
µSv/h)
N
15.1.1
C
Delete notes 1 and 2.
Add to note 4: Attention is drawn to the
fact that a standard is under preparation
(presently prEN 50074) for socket-
outlets which allow connection of Class
II appliances only.
Add to note 4: Attention is drawn to the
fact that a standard is under preparation
(presently prEN 50074) for socket-
outlets which allow connection of Class
II appliances only.
15.1.1
S
(DK) Mains plug according to Heavy
Current Regulations, Section 107-2-D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
Current Regulations, Section 107-2-D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
P
15.1.1
S
(IE) Mains plug, flexible cord, according
to statutory Instrument 525: 1997
to statutory Instrument 525: 1997
P
15.1.1
S
(NO) Mains socket outlets CI.II
P
15.1.1
S
(GB) Mains plug, flexible cord,
according to statutory Instrument 1768:
1994
according to statutory Instrument 1768:
1994
P
15.2
C
Delete note 2
16.1
C
Delete note 1
-APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 2 of 3 -
Order No. 51563
16.2
C
Delete the note
20
C
Delete note 2
APPENDIX
ANNEX B (normative)
N
Annex B
C
Delete note 2
B.5.4.1
S
(NO) Marking stating that the apparatus
must be connected to an earthed mains
socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
must be connected to an earthed mains
socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
B.5.4.1
S
(SE) Marking stating that the apparatus
must be connected to an earthed mains
socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat uttag
när den ansluts till ett nätverk"
must be connected to an earthed mains
socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat uttag
när den ansluts till ett nätverk"
B.5.4.1 e)
C
C
Delete notes 1 and 2
B.8.1
C
Delete notes 1, 2 and 3
B.8.1
S
(DK) Method b) is permitted only for
PERMANENTLY CONNECTED
APPARATUS
PERMANENTLY CONNECTED
APPARATUS
B.8.1
S
(NO) Method b) is not permitted
B.8.2
C
Delete the note
B.14.12
C
Delete notes 1 and 2
B.14.12
S
(DK) The following note is added: NOTE
in Denmark the use of surge
suppressors between the
TELECOMMUNICATION NETWORK
and conductive ACCESSIBLE parts or
TERMINALS which are considered to
be ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
in Denmark the use of surge
suppressors between the
TELECOMMUNICATION NETWORK
and conductive ACCESSIBLE parts or
TERMINALS which are considered to
be ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.