Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 34 of 39 -
Order
No.
51563
LIST OF CRITICAL COMPONENTS (continude)
Part No
Component/
Object
Object
Manufacturer
Type / Model
Ratings /
Technical Data
Technical Data
Complies
with the
following
standard
with the
following
standard
Marks of
conformity
granted **
conformity
granted **
F901
F902
F902
Outlet fse
alt.
alt.
alt.
alt.
Littelfuse.
Bel Fuse.
Save Fusetech.
Bel Fuse.
Save Fusetech.
0663
MRT
SR-5
MRT
SR-5
T2,5A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
F907 Main
fuse
alt.
alt.
alt.
alt.
alt.
Orsel Co. Ltd.
Littelfuse
SUN Electronics
Walter Electronic.
Littelfuse
SUN Electronics
Walter Electronic.
50T
218 06.3
5T
TSD
218 06.3
5T
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F905
F906
F906
Sec. fuse
alt.
alt.
alt.
alt.
alt.
alt.
Orsel Co. Ltd.
Littelfuse
SUN Electronics
Walter Electronic.
Littelfuse
SUN Electronics
Walter Electronic.
50T
218 06.3
5T
TSD
218 06.3
5T
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
F903
F904
F904
Sec. fuse
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
Littelfuse.
S51
218 008
218 008
SB 8A 250V
T8A L 250V
T8A L 250V
UL248-14
IEC60127
IEC60127
1.), UL
1.)
1.)
C124 X-capacitor
alt.
alt.
alt.
alt.
alt.
Pilkor Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
ISKRA Elect.
Okaya Electric Inc.
Yuchang Electronics.
PCX2 335M
KNB1530
RE104
WBU1942
KNB1530
RE104
WBU1942
0.1uF 275V
X2
X2
IEC60384-
14, 2
14, 2
nd
ed.
FIMKO
FIMKO
VDE
FIMKO
FIMKO
VDE
FIMKO
C904
(Relay
across)
across)
X-capacitor
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Capacitor.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF,
250V, X1.
250V, X1.
IEC60384-
14, 2
14, 2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
DC
Brush-
less Fan
SUNONWEALTH
Electric Machine
Electric Machine
KD1206PTS3 KC12V,
0,8A
16 CFM
IEC60950 TUV
PCB
base
material
Various
Various
Min. 94V-0
UL 796
UL
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998
-
IEC 60065, 6th edition : 1998
-
- Page 35 of 39 -
Order
No.
51563
FAULT CONDITION TESTS
P
Ambient temperature
23 - 26°C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault Test
V
Short
current
current
Test
time
time
Fuse No
Current
through
fuse (A)
through
fuse (A)
Mains power/temperatures/results
D991
S – c
253
AC – ‘+’
10min
F907
F903
F904
F903
F904
4,26 Normal
operated.
Input current stabilised at 2,18A.
F904 opened.
No hazard.
F904 opened.
No hazard.
D991
S – c
207
AC – ‘+’
10min
F907
F903
F904
F903
F904
5,03 Normal
operated.
Input current stabilised at 2,06A.
F904 opened.
No hazard.
F904 opened.
No hazard.
D991
S – c
253
AC – ‘-‘
10min
F907
F903
F904
F903
F904
4,13 Normal
operated.
Input current stabilised at 2,13A.
F903 opened.
No hazard.
F903 opened.
No hazard.
D992
S – c
253
AC – ‘+’
10min
F907
F905
F906
F905
F906
9,0 Normal
operated.
Input current stabilised at 2,20A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
S – c
207
AC – ‘+’
10min
F907
F905
F906
F905
F906
4,20 Normal
operated.
Input current stabilised at 2,12A.
F906 opened.
No hazard.
F906 opened.
No hazard.
D992
S – c
253
AC – ‘-’
10min
F907
F905
F906
F905
F906
4,50 Normal
operated.
Input current stabilised at 2,18A.
F905 opened.
No hazard.
F905 opened.
No hazard.
C122
S – c
253
-
10min
F907
2,33
FL display off immediately.
Input current stabilised at 2,18A
R101 opened..
No hazard.
Input current stabilised at 2,18A
R101 opened..
No hazard.
C120
S – c
253
-
15min
F907
2,25
FL display off immediately.
Input current stabilised at 2,24A.
No component damaged.
No hazard.
Input current stabilised at 2,24A.
No component damaged.
No hazard.
C119
S – c
253
-
15min
F907
2,46
FL display off immediately.
Input current stabilised at 2,25A.
R101 opened.
D101, D102, Q104 damaged.
No hazard.
Input current stabilised at 2,25A.
R101 opened.
D101, D102, Q104 damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 36 of 39 -
Order
No.
51563
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test
time
time
Fuse No
Current
through
fuse (A)
through
fuse (A)
Mains power/temperatures/results
C117
S – c
253
-
20min
F907
2,25
Normal operated.
Input current stabilised at 2,25A.
No component damaged.
No hazard.
Input current stabilised at 2,25A.
No component damaged.
No hazard.
C951
S – c
253
-
10min
F907
2,24
Normal operated.
Input current stabilised at 2,24A.
R950 opened.
No hazard.
Input current stabilised at 2,24A.
R950 opened.
No hazard.
Q803
S – c
253
C – E
10min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,02A.
F905, F906 opened.
Q804 damaged.
No hazard.
Input current stabilised at 0,02A.
F905, F906 opened.
Q804 damaged.
No hazard.
Q803
S – c
253
C – B
10min
F907
F905
F906
F905
F906
3,04
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C607
S – c
253
-
30min
F907
F905
F906
F905
F906
2,64
Surr. L ch. output voltage dropped
to 2,3V ac immediately.
Input current stabilised at 2,07A.
R821 opened.
No hazard.
to 2,3V ac immediately.
Input current stabilised at 2,07A.
R821 opened.
No hazard.
Q804
S – c
253
C – E
10min
F907
F905
F906
F905
F906
8,21
Unit shut down immediately.
Input current stabilised at 0,02A.
F905, F906 opened.
Q803 damaged.
No hazard.
Input current stabilised at 0,02A.
F905, F906 opened.
Q803 damaged.
No hazard.
Q804
S – c
253
C – B
10min
F907
F905
F906
F905
F906
2,94
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard
Input current stabilised at 0,02A.
No component damaged.
No hazard
C813
S – c
253
-
10min
F907
F905
F906
F905
F906
2,20
Surr. L ch output off immediately.
Input current stabilised at 1,99A.
No component damaged.
No hazard.
Input current stabilised at 1,99A.
No component damaged.
No hazard.
Q659
S – c
253
C – E
10min
F907
F903
F904
F903
F904
-
Unit shut down immediately.
Input current stabilised at 0,02A.
R658, F903, F904 opened.
Q653 damaged.
No hazard.
Input current stabilised at 0,02A.
R658, F903, F904 opened.
Q653 damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 39 -
Order
No.
51563
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test
time
time
Fuse No
Current
through
fuse (A)
through
fuse (A)
Mains power/temperatures/results
Q659
S – c
253
C – B
10min
F907
F903
F904
F903
F904
2,98
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C633
S – c
253
-
10min
F907
F903
F904
F903
F904
2,59
Front L ch. output voltage dropped
to 2,4V ac immediately.
Input current stabilised at 2,06A.
R633 opened.
No hazard.
to 2,4V ac immediately.
Input current stabilised at 2,06A.
R633 opened.
No hazard.
Q653
S – c
253
C – E
10min
F907
F903
F904
F903
F904
-
Unit shut down immediately.
Input current stabilised at 0,02A.
F903, F904 opened.
Q659 damaged.
No hazard.
Input current stabilised at 0,02A.
F903, F904 opened.
Q659 damaged.
No hazard.
Q653
S – c
253
C – B
10min
F907
F903
F904
F903
F904
2,45
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C568
S – c
253
-
15min
F907
F903
F904
F903
F904
2,10
Front L ch output off immediately.
Input current stabilised at 2,02A.
No component damaged.
No hazard.
Input current stabilised at 2,02A.
No component damaged.
No hazard.
C902
S – c
253
-
10min
F907
F905
F906
F905
F906
6,40
Surround and Center output off
immediately.
Input current stabilised at 1,49A.
F905, F906 opened.
No hazard.
immediately.
Input current stabilised at 1,49A.
F905, F906 opened.
No hazard.
C902
S – c
207
-
10min
F907
F905
F906
F905
F906
6,10
Surround and Center output off
immediately.
Input current stabilised at 1,40A.
F905, F906 opened.
No hazard.
immediately.
Input current stabilised at 1,40A.
F905, F906 opened.
No hazard.
C915
S – c
253
-
10min
F907
F903
F904
F903
F904
3,90
Front and S/B Multi output off
immediately.
Input current stabilised at 1,17A.
F903, F904 opened.
No hazard.
immediately.
Input current stabilised at 1,17A.
F903, F904 opened.
No hazard.
C915
S – c
207
-
10min
F907
F903
F904
F903
F904
-
Front and S/B Multi output off
immediately.
Input current stabilised at 1,10A.
F903, F904 opened.
No hazard.
immediately.
Input current stabilised at 1,10A.
F903, F904 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 340 (serv.man11) service manuals if exist.