DOWNLOAD Harman Kardon AVR 340 (serv.man11) Service Manual ↓ Size: 1.05 MB | Pages: 53 in PDF or view online for FREE

Model
AVR 340 (serv.man11)
Pages
53
Size
1.05 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-340-sm11.pdf
Date

Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 30 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
18 
MECHANICAL STRENGTH OF 
PICTURE TUBES AND 
PROTECTION AGAINST THE 
EFFECTS OF IMPLOSION   
 
18.1 
Picture tube separately approved    
No picture tube 
 
Picture tubes > 16 cm intrinsically 
protected  
 
 
Non-intrinsically protected tubes 
> 16 cm used with protective 
screen  
 
18.2 
Intrinsically protected tubes: tests 
on 12 samples   
 
18.2.1 
Samples subject to ageing: 6   
 
18.2.2 
Samples subject to implosion test: 
6  
 
18.2.3 
Samples subject to mechanical 
strength test (steel ball): 6   
 
18.3 
Non-intrinsically protected tubes 
tested to 18.3   
 
 
19 
STABILITY AND MECHANICAL 
HAZARDS  
 
 
Mass of the equipment exceeding 
18 kg      
Mass < 18 kg. 
19.1 
Test on a plane, inclined at 10
° to 
the horizontal   
 
19.2 
100 N force applied vertically 
downwards  
 
19.3 
Smooth edges and corners   
There is no hazardous edges or corners when the 
apparatus is operating in normal position   
19.4 
Glass surfaces with an area 
exceeding 0,1 m² or maximum 
dimension > 450 mm, pass the test 
of 19.4.1   
No glass surface. 
 
 
20 
RESISTANCE TO FIRE   
 
20.1 
Electrical components and 
mechanical parts 
 
 
 Apparatus 
design 
Resistance to fire is achieved by a combination of 
engineering design, production methods and by using 
materials with low flammability for internal parts 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 31 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
 
a) Exemption for components 
contained in an enclosure of 
material FV 0 to IEC 60 707 with 
openings not exceeding 1 mm in 
width  
 
 
b) Exemption for small components 
as defined in 20.1   
PCB is of flammability class FV 1 or better, and 
exception is made for small components. 
20.1.1 
Electrical components meet the 
requirements of 14.2.5, 14.4, 14.5.3 
or 14.6.6   
No other electrical components with additional 
flammability requirements. 
20.1.2 
Insulation of internal wiring working 
at voltages > 4 kV or leaving an 
internal fire enclosure, not 
contributing to the spread of fire   
No wires working at voltages > 4kV or leaving an internal 
fire enclosure 
20.1.3 
Material of printed circuit boards on 
which the available power exceeds 
15 W at a voltage between 50 V 
and 400 V (peak) a.c. or d.c. meets 
FV 1 or better to IEC 60 707, 
unless used in a fire enclosure   
All PCB are of base material with flammability category 
FV 0. See List of Critical Components 
 
Material of printed circuit boards on 
which the available power exceeds 
15 W at a voltage exceeding 400 V 
(peak) a.c. or d.c. meets FV 0 to 
IEC 60 707   
 
20.1.4 
Components and parts not covered 
by 20.1.1, 20.1.2 and 20.1.3 (other 
than fire enclosures) mounted 
nearer to a potential ignition source 
than the distances in Table 13 
comply with the relevant 
flammability category in Table 13   
 
 
Components and parts as above 
but shielded from a potential 
ignition source, with the barrier area 
in accordance with Table 13 and 
fig. 13   
 
20.2 Fire 
enclosure 
 
 
20.2.1 
Potential ignition sources with open 
circuit voltage > 4 kV (peak) a.c. or 
d.c. contained in a fire enclosure to 
FV 1   
No voltages exceeding 4kV, no fire enclosure 
requirement. 
20.2.2 
Internal fire enclosures with 
openings not exceeding 1 mm in 
width and with openings for wires 
completely filled   
 
20.2.3 Requirements 
of 20.2.1 and 20.2.2 
met by an internal fire enclosure   
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 32 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
ANNEX A, ADDITIONAL 
REQUIREMENTS FOR 
APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER   
 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 
5.4.1 a) does not apply   
Not intended for outdoor use. 
A.10.2.1 
Enclosure provides protection 
against splashing water   
 
A.10.2.2 
Humidity treatment carried out for 
7 days   
 
 
ANNEX B, APPARATUS TO BE 
CONNECTED TO THE 
TELECOMMUNICATION 
NETWORKS  
 
B.5.4.1 
e) Where the separation of TNV 
circuits from other circuits relies on 
protective earthing the instructions 
make it clear that protective earthing 
is essential   
No intended for telecommunication networks. 
B.8.1 
TNV circuits separated from the 
mains circuit and from hazardous 
live parts by either: 
 
 
 
a) double or reinforced insulation   
 
 
b) basic insulation with earthed 
protective screening   
 
B.8.2 
TNV circuits separated from circuits 
other than those in B.8.1 and from 
accessible conductive parts by basic 
insulation meeting the requirements 
for clearances and creepage 
distances for the voltages 
concerned  
 
B.9.1.1 
TNV circuit terminals contacts which 
cannot be touched by probe B.1, 
exempt from the requirements 
inaccessible terminal contacts in 
9.1.1  
 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1   
 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 33 of 39 - 
 
 
   
 Order 
No. 
51563 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued)
 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
For 
CENELEC 
Countries 
Mains plug 
with cord 
Kenic Electric Mfg. 
KE-25 
H03VVH2-F 
10-16A/250V 
6A/250V 
IEC60884-1
VDE 
 
alt 
Volex (Asia) Pte. 
Ltd. 
M3204 
H03VVH2-F 
10-16A/250V 
6A/250V 
IEC60884-1
VDE 
 
alt 
HWAJIN KDK Co. 
KKP-4819C 
H03VVH2-F 
10-16A/250V 
6A/250V 
IEC60884-1
VDE 
For U.K. 
Mains plug 
with cord 
Volex (Asia) Pte Ltd. 
MP5005 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
ASTA 
 
alt   
Volex (Asia) Pte Ltd. 
MP5004A 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
ASTA 
 alt 
PHINO 
Electronics 
Co., Ltd 
PHP-307F 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
BSI 
 
alt 
Winbo Industries 
MS 323N 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
BSI 
 
alt 
Luen Tai (IP`S) Elect. 
Kenic Electric Mfg. 
9518 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
BSI 
 
alt 
Well shin Enterprise 
Co. Ltd. 
WS-012A 
H03VVH2-F 
13A/250V 
6A/250V 
BS1363 
BS6500 
BSI 
OL91 Mains 
Socket-outlet 
Dae Ryung 
Electronics. 
A3-04-D007 2.5A/250V 
IEC60884-1
NEMKO 
SW1 
Mains switch 
POSTEC Electric. SDL1P-B  5A/80A 
250V 
IEC60065 
IEC61058-1
VDE 
RY94 
Mains relay 
Tyco Electronics 
SDT-S-112DMR
8A/120A 250V 
IEC60065 
IEC61058-1
SEMKO 
- Mains 
transformer 
 
Bobbin Mti. 
Thermal fuse 
Seoul Electronics & 
Telecom Co., Ltd. 
 
Wintech Ploymer Ltd. 
Micro Devices. 
KLT5W022ZE 
CLT5W022ZE 
 
CN9030 
E4A51167C 
230V Class B 
 
 
V-0, 155°C 
10A/250V 167°C
 
IEC60065 
clause 14.3
 
UL94 
IEC60691 
1.) 
 
 
UL E213445
VDE 
- Sub 
transformer 
 
Bobbin Mti. 
Thermal fuse 
Seoul Electronics & 
Telecom Co., Ltd. 
 
LG Chemical Ltd.. 
Anzen Dengu Co., Ltd.
KLT5J038ZE 
CLT5J038ZE 
 
GP2306F(#) 
K11 
230V Class E 
 
 
V-0, 140°C 
1A/250V, 115°C
 
IEC60065 
clause 14.3
 
UL94 
IEC60691 
1.) 
 
 
UL E67171 
VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6 Edition :1998 
Page of 53
Display