Harman Kardon AVR 340 (serv.man11) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 6 of 39 -
Order
No.
51563
5.1
Identification, maker, model
See copy of the markings
P
Class II symbol
Adequate symbol applied
P
Rated supply voltage and symbol
AC-symbol (
~
) and 230V marked
P
Rated mains frequency
50Hz
P
Rated current or power
consumption
consumption
370W
P
5.2
Earth terminal
Class II apparatus
N
Hazardous live terminals
No live parts accessible
P
Supply output terminals (other than
mains)
mains)
The power is marked close to the socket outlet.
see copy of the marking
see copy of the marking
P
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
connection with CAUTION of opening. Further; no
incorrect use of this symbol is found.
P
5.4
Instructions for use
Installation instruction was provided in English.
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied.
P
Hazardous live terminals,
instructions for wiring
instructions for wiring
No live terminal.
N
Instructions for replacing lithium
battery
battery
No lithium battery
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No explanation required (indication in the form of
illumination)
illumination)
N
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF
from the mains, info required
connected equipment
If not completely switched OFF
from the mains, info required
The apparatus is not for permanent connection
N
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 39 -
Order
No.
51563
6 HAZARDOUS
RADIATION
No radiation
N
6.1
High voltage (kV).
N
Focus voltage (kV)
N
Amount of radiation
N
6.2
Non-ionizing radiation (laser
radiation)
radiation)
No laser radiation
N
6.2.1
Opening of any cover by hand
N
Mechanical interlocking device
N
Accessible emission normal
operation / classification
operation / classification
N
Labelling
N
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
N
Warning label requirement
N
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
OFF/Stand-by mode (ref. 14.6.2)
Position of the functional switch (W)
In OFF/Stand-by position, the power consumption is less
than 15W.
than 15W.
P
Surge current needed in clause
14.6 when testing mains switches
or functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
14.6 when testing mains switches
or functional switches conductively
connected to the supply mains.
(Note! Mains socket-outlet Clause
14.6.10.)
Ref. clause 14,6
P
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 39 -
Order
No.
51563
7.1
Standby mode
U
=
207,0
V, I
=
0,017
A, P
=
2,6
W,
Pout =
W
U
=
230,0
V, I
=
0,018
A, P
=
3,1
W,
Pout =
W
U
=
243,8
V, I
=
0,019
A, P
=
3,5
W,
Pout =
W
U
=
253,0
V, I
=
0,020
A, P
=
3,9
W,
Pout =
W
Measured at maximum non-clipped output:
7.1 U
=
207,0
V, I
=
4,42
A, P
=
768
W,
Pout =
2 x 76,5
W (F)
Pout =
1 x 77,2
W (C)
Pout =
2 x 76,3
W (R)
Pout =
2 x 77,2
W (S/M)
U
=
230,0
V, I
=
4,77
A, P
=
919
W,
Pout =
2 x 76,5
W (F)
Pout =
1 x 77,2
W (C)
Pout =
2 x 76,3
W (R)
Pout =
2 x 77,2
W (S/M)
U
=
243,8
V, I
=
4,92
A, P
=
1004
W,
Pout =
2 x 76,5
W (F)
Pout =
1 x 77,2
W (C)
Pout =
2 x 76,3
W (R)
Pout =
2 x 77,2
W (S/M)
U
=
253,0
V, I
=
4,97
A, P
=
1048
W,
Pout =
2 x 76,5
W (F)
Pout =
1 x 77,2
W (C)
Pout =
2 x 76,3
W (R)
Pout =
2 x 77,2
W (S/M)
LSL
=
7 channel x 8
Ω
Measured at 1/8 of maximum non-clipped output:
7.1 U
=
207,0
V, I
=
2,15
A, P
=
342
W,
Pout =
2 x 9,6
W
(F)
Pout =
1 x 9,7
W
(C)
Pout =
2 x 9,5
W
(R)
Pout =
2 x 9,7
W
(S/M)
U
=
230,0
V, I
=
2,20
A, P
=
386
W,
Pout =
2 x 9,6
W
(F)
Pout =
1 x 9,7
W
(C)
Pout =
2 x 9,5
W
(R)
Pout =
2 x 9,7
W
(S/M)
U
=
243,8
V, I
=
2,23
A, P
=
414
W,
Pout =
2 x 9,6
W
(F)
Pout =
1 x 9,7
W
(C)
Pout =
2 x 9,5
W
(R)
Pout =
2 x 9,7
W
(S/M)
U
=
253,0
V, I
=
2,24
A, P
=
431
W,
Pout =
2 x 9,6
W
(F)
Pout =
1 x 9,7
W
(C)
Pout =
2 x 9,5
W
(R)
Pout =
2 x 9,7
W
(S/M)
LSL
=
7 channel x 8
Ω
-
IEC 60065, 6th edition : 1998
-
- Page 9 of 39 -
Order
No.
51563
7.1
Operating conditions (power audio amplifier, 1/8 of maximum non-clipped output):
U
=
253,0
V, I
=
2,24
A, P
=
431
W,
Pout =
2 x 9,6
W
(F)
Pout =
1 x 9,7
W
(C)
Pout =
2 x 9,5
W
(R)
Pout =
2 x 9,7
W
(S/M)
LSL
=
7 channel x 8
Ω
Loudspeaker system(s)
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Right and Left for SB/MULTI channels.
Marking of loudspeaker terminals
FRONT, CENTER, SURROUND,
SB/MULTI, SPEAKERS (8
Ω)
U =
253
V
4 Ohm
8 Ohm
16 Ohm
Left
right
left
right
left
right
Measured max. output voltage in Vp
F)
35,0
C) 35,1
R) 34,9
S/M) 35,1
R) 34,9
S/M) 35,1
F) 35,0
C) -
R) 34,9
S/M) 35,1
C) -
R) 34,9
S/M) 35,1
Measured max. output power in W
F)
76,5
C) 77,2
R) 76,3
S/M) 77,2
R) 76,3
S/M) 77,2
F) 76,5
C) -
R) 76,3
S/M) 77,2
C) -
R) 76,3
S/M) 77,2
Measured max. mains power in W
1048
Operation of protective devices
No fuse links operate during normal operating condition
P
7.1.1
Temperature rise of accessible
parts
parts
(see table below/next page)
P
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table below/next page)
P
7.1.3
Temperature rise of parts acting as
a support or as a mechanical
barrier
a support or as a mechanical
barrier
(see table below/next page)
P
7.1.4
Temperature rise of windings
(see table below/next page)
P
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table below/next page)
P