Reference No. : 54120802A                                                                                                                        Page 11
 
◀  Anam EMC Test Laboratory  ▶
 
 
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE   
  FREQUENCY RANGE 30MHz TO 1,000MHz
 
 
  7.1. Operating environment 
Temperature 
: 25℃ 
Relative humidity  : 55% 
 
    7.2. Test set-up and procedure 
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒. 
 
The level of the test signal, which was connected to the receiver through a 
combining network, was set to give 70 ㏈㎶  at the input of the EUT. 
The signal was an unmodulated carrier. 
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic 
frequencies was measured with the receiver tuned to a selected number of FM 
sound broadcast channels. Disturbance voltage due to all other sources was 
measured with the receiver tuned to the channel 98.3 ㎒ respectively. 
 
   7.3. Measurement uncertainty 
 
Antenna terminal disturbance voltage, Quasi-peak detection:  ±2.0 ㏈ 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
7.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
R & S 
ESCI 
100348 
Measurement 
                      Receiver   
 
 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Combining network 
Municom 
MCL ZFSC-2-11 
942604 
Matching pad 
(50~75Ω) 
R & S 
RAM 358 
837254/004 
* R & S: Rohde & Schwarz 
 
 
 
 
 
 
 
 
Reference No. : 54120802A                                                                                                                        Page 12
 
◀  Anam EMC Test Laboratory  ▶
 
 
7.5. Test protocols 
 
Date: January 31, 2008 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
98.2 
54.0 
40.6 
 2 
196.4 
50.0 
37.5 
 3 
294.6 
50.0 
31.0 
 4 
392.8 
52.0 
87.5 5 491.0 
52.0 
37.9 
 6 
589.2 
52.0 
33.0 
 7 
687.4 
52.0 
46.8 
 8 
785.6 
52.0 
32.1 
 9 
883.8 
52.0 
 10 
982.0 
52.0 
 1 
108.7 
54.0 
40.1 
 2 
217.4 
50.0 
37.8 
 3 
326.1 
52.0 
33.9 
98.0 4 434.8 
52.0 * 
 5 
543.5 
52.0 
36.5 
 6 
652.2 
52.0 
37.9 
 7 
760.9 
52.0 
 8 
869.6 
52.0 
 9 
978.3 
52.0 
 1 
118.7 
54.0 
39.9 
 2 
237.4 
50.0 
39.2 
 3 
356.1 
52.0 
35.1 
108.0 4 474.8 
52.0 32.1 
 5 
593.5 
52.0 
37.8 
 6 
712.2 
52.0 
41.8 
 7 
830.9 
52.0 
41.6 
 8 
949.6 
52.0 
 
 
 
 
Reference No. : 54120802A                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶ 
    
 
 
 
Limit 
according 
to 
EN55013:2001+A2(2006) 
 
8. DISTURBANCE POWER 
8.1. Operating environment 
Temperature 
: 23℃ 
Relative humidity  : 50% 
 
      8.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN55013, 5.6. 
 
   8.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   8.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Measurement 
receiver 
R & S 
ESCI 
100348 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
 
* R & S: Rohde & Schwarz 
 
 
 
 
Reference No. : 54120802A                                                                                                                        Page 14
 
◀  Anam EMC Test Laboratory  ▶
 
 
8.5. Test protocols 
 
Date: January 25, 2008 
 
The equipment does comply with the requirements. Operating condition: The   
 
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being 
 
supplied from the Oscillator or test DVD. An absorbing clamp was placed 
 
around all leads. At each mode, the maximum value at each testing frequency 
 
and each output lead was registered and attached as follows. 
Limit(㏈㎺) Result(㏈㎺) 
Test Lead 
Freq. 
(㎒) 
QP AV QP  AV 
PHONES 
172.03 
50.3 40.3 33.2  32.5 
FRONT COAXIAL 
110.59 
48.0 38.0 36.4  34.1 
FRONT S-VIDEO 
172.03 
50.3 40.3 30.6  30.1 
FRONT AUDIO, VIDEO 
110.59 
48.0 38.0 32.3  30.4 
S-VIDEO VIDEO 1 
172.03 
50.3 40.3  * 
S-VIDEO VIDEO 2 OUT 
172.03 
50.3 40.3  * 
S-VIDEO VIDEO 2 IN 
172.03 
50.3 40.3  * 
S-VIDEO VIDEO 3 IN 
172.03 
50.3 40.3  * 
S-VIDEO MONITOR OUT 
172.03 
50.3 40.3  * 
HDMI 3 
172.03 
50.3 40.3  * 
HDMI 2 
172.03 
50.3 40.3  * 
HDMI 1 
172.03 
50.3 40.3  * 
HDMI MONITOR OUT 
172.03 
50.3 40.3  * 
ANALOG 1 
172.03 
50.3 40.3  * 
ANALOG 2 OUT 
172.03 
50.3 40.3  * 
ANALOG 2 IN 
172.03 
50.3 40.3  * 
ANALOG 3 
172.03 
50.3 40.3  * 
ANALOG 4 OUT 
172.03 
50.3 40.3  * 
ANALOG 4 IN 
172.03 
50.3 40.3  * 
ANALOG 5 
172.03 
50.3 40.3  * 
6/8CH FL/FR 
61.50 46.2  36.2 
6/8CH SL/SR 
61.50 46.2  36.2 
6/8CH C/SW 
61.50 46.2  36.2 
6/8CH SBL/SBR 
61.50 46.2  36.2 
COAXIAL OUT 
172.03 
50.3 40.3  * 
COAXIAL 1 
172.03 
50.3 40.3  * 
COAXIAL 2 
172.03 
50.3 40.3  * 
COMPONENT VIDEO 1 
172.03 
50.3 40.3  * 
COMPONENT VIDEO 2 
172.03 
50.3 40.3  * 
COMPONENT MONITOR 
OUT 
172.03 
50.3 40.3  * 
Page of 127