Reference No. : 54120802A                                                                                                                        Page 7
 
◀  Anam EMC Test Laboratory  ▶
 
 
5.4. Test instrument 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Shielded room 
Measurement 
                      Receiver 
R & S 
ESCI 
100348 
R & S 
ESH3-Z5 
844249/020 
Artificial mains 
                      Network  EMCO 3825/2 90101718 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
 
* R & S: Rohde & Schwarz 
 
5.5. Test protocol 
 
 
Date: January 31, 2008 
 
Grounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A. 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner .150 66.0 42.3 43.3 56.0 21.7 22.7 
  12.288 60.0 22.2 21.8 50.0 22.3 21.8 
 
 
Ungrounded at the Signal GND Terminal on the Rear Enclosure. 
 
An overview sweep performed with peak detector is included in the test 
report as Annex A 
Quasi-peak (㏈㎶) Average 
(㏈㎶) 
Disturbance value 
Disturbance value 
Mode 
Freq. 
(㎒) 
Limit 
Line 1 
Line 2 
Limit 
Line 1 
Line 2 
Tuner .150 66.0 42.0 43.0 56.0 21.5 22.8 
  12.288 60.0 21.5 20.8 50.0 21.7 20.0 
 
 
 
 
 
 
 
 
ANAL
OG 1 
.150 66.0 51.6 51.5 56.0 26.5 26.8 
  12.288 60.0 21.3 23.5 50.0 21.5 23.5 
 
 
 
 
 
 
 
 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex A (6 Copies). 
 
 
 
Reference No. : 54120802A                                                                                                                        Page 8
 
◀  Anam EMC Test Laboratory  ▶
 
 
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz   
TO 1,000MHz
 
 
6.1. Operating environment 
Temperature 
: 08℃ 
Relative humidity  : 50% 
 
    6.2. Test set-up and procedure 
 
The measurement was performed on an open area test site with a reference   
 
ground plane and at a distance of 3m. The height of the measuring antenna was 
 
varied between 1 to 4m and the table was rotated a full revolution in order to 
obtain maximum value of the electric field intensity. The measurement was 
made in both the vertical and horizontal polarization, and the maximum value is   
presented in the report. 
The measurement was performed with a quasi-peak detector. 
Disturbance radiation due to the fundamental and harmonic frequencies of the 
local oscillator and the other source were measured on a selected number of FM 
sound broadcast channels. About the Disturbance radiation value from the other 
source, the sixteen maximum values were recorded. 
The test was measured with the main unit and the remote control unit. 
 
6.3. Measurement uncertainty 
 
Radiated disturbance electric field intensity, 30    ~    300 ㎒:  ±2.0 ㏈ 
 
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
6.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Test site 
Open area test site 
Measurement 
Receiver 
R & S 
ESCI 
100348 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Test DVD 
 
TDV-540 
N/A 
Bi-conical Ant. 
Schwarzbeck 
VHA9103 
9103 1135 
Log-periodic Ant. 
Schwarzbeck 
UHALP 9108-A  91081098 
Ant. Master 
EMCO 
1051-12 
90121554 
Turn table 
EMCO 
1080-1.211 
90121504 
 
 
Reference No. : 54120802A                                                                                                                        Page 9
 
◀  Anam EMC Test Laboratory  ▶
 
 
6.5. Test protocols 
 
Date: January 28, 2008 
Disturbance radiation due to the local oscillator. 
Disturbance value(㏈㎶/m) 
Channel Harmonic  Measured 
freq. (㎒) 
Limit 
(㏈㎶/m) 
Horizon Vertical 
 1 
98.2 
60.0 
* * 
 2 
196.4 
52.0 
* * 
 3 
294.6 
52.0 
* * 
 4 
392.8 
56.0 
* * 
87.5 5 491.0 
56.0 * * 
 6 
589.2 
56.0 
* * 
 7 
687.4 
56.0 
* * 
 8 
785.6 
56.0 
* * 
 9 
883.8 
56.0 
* * 
 10 
982.0 
56.0 
* * 
 1 
108.7 
60.0 
* * 
 2 
217.4 
52.0 
* * 
 3 
326.1 
56.0 
* * 
98.0 4 434.8 
56.0 * * 
 5 
543.5 
56.0 
* * 
 6 
652.2 
56.0 
* * 
 7 
760.9 
56.0 
* * 
 8 
869.6 
56.0 
* * 
 9 
978.3 
56.0 
* * 
 1 
118.7 
60.0 
* * 
 2 
237.4 
52.0 
* * 
 3 
356.1 
56.0 
* * 
108.0 4 474.8 
56.0  * * 
 5 
593.5 
56.0 
* * 
 6 
712.2 
56.0 
* * 
 7 
830.9 
56.0 
* * 
 8 
949.6 
56.0 
* * 
 
 
 
Reference No. : 54120802A                                                                                                                        Page 10
 
◀  Anam EMC Test Laboratory  ▶
 
 
Disturbance radiation due to the other source. 
Disturbance value(㏈㎶/m) 
Channel Harmonic Measured 
freq. (㎒) 
Limit 
(㏈㎶/m) 
Horizon Vertical 
  
86.01 
40.0 
32.5 
Others   151.55 
40.0 
* 34.2 
  
172.03 
40.0 
36.6 30.8 
 30 
221.18 
40.0 
30.0 26.6 
 
1,000  ㎒ 
270.34 
47.0 
39.0 30.0 
  
319.50 
47.0 
40.0 35.0 
  
368.64  47.0 
30.0 33.2 
  
400.00 
47.0 
37.2 39.7 
  
454.67 
47.0 
34.5 34.0 
 
 
466.95 
47.0 
35.5 35.6 
 
 
565.28 
47.0 
37.8 39.1 
 
 
811.01 
47.0 
40.8 43.0 
 
 
860.16 
47.0 
44.0 43.0 
 
 
909.32 
47.0 
41.0 41.2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*: less than25.0 ㏈㎶/m 
 
 
     
  Limit according to EN55013:2001
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127