Harman Kardon AVR 260 (serv.man2) EMC - CB Certificate ▷ View online
Reference No. : 54120802A Page 7
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
R. C. Oscillator
Network EMCO 3825/2 90101718
R. C. Oscillator
Kenwood
AG-203A
3090241
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: January 31, 2008
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .150 66.0 42.3 43.3 56.0 21.7 22.7
12.288 60.0 22.2 21.8 50.0 22.3 21.8
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner .150 66.0 42.0 43.0 56.0 21.5 22.8
12.288 60.0 21.5 20.8 50.0 21.7 20.0
ANAL
OG 1
.150 66.0 51.6 51.5 56.0 26.5 26.8
12.288 60.0 21.3 23.5 50.0 21.5 23.5
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).
Reference No. : 54120802A Page 8
◀ Anam EMC Test Laboratory ▶
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz
TO 1,000MHz
6.1. Operating environment
Temperature
: 08℃
Relative humidity : 50%
6.2. Test set-up and procedure
The measurement was performed on an open area test site with a reference
ground plane and at a distance of 3m. The height of the measuring antenna was
varied between 1 to 4m and the table was rotated a full revolution in order to
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
6.3. Measurement uncertainty
Radiated disturbance electric field intensity, 30 ~ 300 ㎒: ±2.0 ㏈
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
6.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Test site
Open area test site
-
Measurement
Receiver
R & S
ESCI
100348
Signal Generator
Anritsu
MG3632A
MT79870
Test DVD
TDV-540
N/A
Bi-conical Ant.
Schwarzbeck
VHA9103
9103 1135
Log-periodic Ant.
Schwarzbeck
UHALP 9108-A 91081098
Ant. Master
EMCO
1051-12
90121554
Turn table
EMCO
1080-1.211
90121504
Reference No. : 54120802A Page 9
◀ Anam EMC Test Laboratory ▶
6.5. Test protocols
Date: January 28, 2008
Disturbance radiation due to the local oscillator.
Disturbance radiation due to the local oscillator.
Disturbance value(㏈㎶/m)
Channel Harmonic Measured
freq. (㎒)
Limit
(㏈㎶/m)
Horizon Vertical
1
98.2
60.0
* *
2
196.4
52.0
* *
3
294.6
52.0
* *
4
392.8
56.0
* *
87.5 5 491.0
56.0 * *
6
589.2
56.0
* *
7
687.4
56.0
* *
8
785.6
56.0
* *
9
883.8
56.0
* *
10
982.0
56.0
* *
1
108.7
60.0
* *
2
217.4
52.0
* *
3
326.1
56.0
* *
98.0 4 434.8
56.0 * *
5
543.5
56.0
* *
6
652.2
56.0
* *
7
760.9
56.0
* *
8
869.6
56.0
* *
9
978.3
56.0
* *
1
118.7
60.0
* *
2
237.4
52.0
* *
3
356.1
56.0
* *
108.0 4 474.8
56.0 * *
5
593.5
56.0
* *
6
712.2
56.0
* *
7
830.9
56.0
* *
8
949.6
56.0
* *
Reference No. : 54120802A Page 10
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Disturbance value(㏈㎶/m)
Channel Harmonic Measured
freq. (㎒)
Limit
(㏈㎶/m)
Horizon Vertical
86.01
40.0
32.5
*
Others 151.55
40.0
* 34.2
172.03
40.0
36.6 30.8
30
~
221.18
40.0
30.0 26.6
1,000 ㎒
270.34
47.0
39.0 30.0
319.50
47.0
40.0 35.0
368.64 47.0
30.0 33.2
400.00
47.0
37.2 39.7
454.67
47.0
34.5 34.0
466.95
47.0
35.5 35.6
565.28
47.0
37.8 39.1
811.01
47.0
40.8 43.0
860.16
47.0
44.0 43.0
909.32
47.0
41.0 41.2
*: less than25.0 ㏈㎶/m
Limit according to EN55013:2001
Click on the first or last page to see other AVR 260 (serv.man2) service manuals if exist.